• Title/Summary/Keyword: Qi 시스템

Search Result 65, Processing Time 0.028 seconds

The encryption research of the sensor gateway for traffic surveillance and control system (교통감시.제어시스템을 위한 센서게이트웨이 암호화 연구)

  • Lim, Il-Kwon;Kim, Young-Hyuk;Park, So-Ah;Gui, Li Qi;Lee, Jae-Kwang;Park, Woo-Jun;Cheon, Byeong-Gu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.477-480
    • /
    • 2010
  • This paper develops a sensor gateway for using Internet for traffic flow control and remote monitoring, it suggest the required protocol with authentication and encryption. The traffic Surveillance and Control System is an important service to the ITS(Intelligent Transportation System). The traffic surveillance and control system's TCP / IP and the Internet network using is may cause damage means accessing from unauthorized users, Subsequent authentication and encryption of data is essential.

  • PDF

The Study on Evaluating Performances of Lab Sacle-Advanced $A_{2}O$ with Changing System Using Biofilm Process (생물막 담체를 이용한 실험실 규모 $A_{2}O$공법의 시스템 변형에 따른 고도처리 성능 평가에 관한 연구)

  • Kim, Min-Sik;Kang, Gu-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, as reinforced water quality standards for wastewater has been announced, more efficient and more powerful wastewater treatment processes are required rather than the existing activated sludge process. In order to meet this demands, we evaluate Task 1-4 about lab scale $A_{2}O$ process using biofilm media. Task 1, 2, and 3 use 'Module A' which has 4 partitions (Anoxic/Anerobic/Oxic/Oxic). Task 4 uses 'Module B' which has 2 partitions including a denitrification reactor with an Inclined plug flow reactor (IPFR) and a nitrification reactor with biofilm media. The denitrification reactor of Module B is designed to be upward flow using IPFR. The result of evaluating at each Task has shown that attached growth system has better capacity of removal efficiency for organic matter and nitrogen with the exception of phosphorus. Task 4 which has the most outstanding removal efficiency has 90.5% of $BOD_{5}$ removal efficiency, 97.8% of ${NH_4}^{+}-N$ removal efficiency, 65% of T-N removal efficiency and 92% of T-P removal efficiency with additional chemical phosphorus removal system operated at HRT 9hr, Qi:Qir 1:2, and BOD/T-N ratio 2.7.

$H_\infty$ Control Apprach to a Magnetic Levitation System with Two Poles on $j_\omega$-Axis

  • Qi, Run-De;Tsuji, Teruo;Oguro, Ryuichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.339-344
    • /
    • 1993
  • An H$_{\infty}$ control system design for a magnetic levitation system is presented. In the control system design, we consider the influence of both disturbances and uncertainties in the model. The main disturbances stem from the position sensors.The uncertainties are divided into electromagnetic and mechanical ones: the former are due to the gain change in the current amplifier, the influence of leakage flux and modelling error in the magnetic circuit and the latter are due to the changes of the mass and the moments of inertia of the vehicle. Therefore, the designed controller is indispensable to guarantee the robustness of this system for both stability and performance. The controller design is based on the standard H$_{\infty}$ optimal control problem. As the novel features in this paper :(1) there are two poles on j.omega.-axis in the control model;(2) an integrator is included in the controller so that equivalently there are three poles on j.omega.-axis in the model. Finally, several experiments and simulations are carried out to verify the high performance and robustness of the designed control system.m.

  • PDF

LOW-DRER $H_\infty$ CONTROLLERS WITH THE MIXWED SENSITIVITY PROBLEMS

  • Qi, Run-De;Tsuji, Teruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.455-460
    • /
    • 1994
  • This paper presents a simple methodology for reducing the order of H$_{\infty}$ controllers in the mixed sensitivity control problems. The key point of this methodology is to transform the generalized plant expression to new one, where the control object and the weighting functions for the sensitivity function may have some poles on the imaginary axis. So that, this methodology makes it possible to use the standard method to solve the general H$_{\infty}$ design problems about the mixed sensitivity problems, even for a servo system or a oscillatory system. We derive that the order of H$_{\infty}$ controllers designed by this methodology may be reduced to n$_{p}$ where n$_{p}$ is the order of the denominator of the control object. It is clear that n$_{p}$ is lower than n$_{p}$ + n$_{s}$, which is the order of H$_{\infty}$ controllers obtained by the ordinary H$_{\infty}$ design method up to now, where n$_{s}$ is the order of the denominator of the weighting function for sensitivity. Finally, a numerical example is given to illustrate the results..lts.ts..lts.lts.

  • PDF

The trends of public transportation interlocking system for ITS (ITS를 위한 대중교통 서비스 동향)

  • Li, Qi Gui;Lim, Il-Kwon;Kim, Young-Hyuk;Park, So-Ah;Lee, Jae-Kwang;Park, Woo-Jun;Cheon, Byeong-Gu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.62-65
    • /
    • 2010
  • ITS(Intelligent Transportation System) is in order to better operate the public transportation. The thesis purpose to introduce how does city buses and underground vehicles input in server-side controls to connecting these two parts, that achieve share information between them. Ready provision of reliable, up-to-date and accurate transport information contributes towards efficient road use, better traffic flow, greater road safety and improved accessibility and promote efficiency in the city.

  • PDF

SDL-OPNET Co-Simulation Technique for the Development of Communication Protocols with an Integrated Approach to Functional Verification and Performance Evaluation (기능 검증 및 성능 평가 통합 접근 방법을 통한 통신 프로토콜 개발을 위한 SDL-OPNET 코-시뮬레이션 기법)

  • Yang, Qi-Ping;Kim, Tae-Hyong
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • While both functional verification and performance evaluation of a system are necessary for the development of effective and reliable communication systems, they have been usually performed individually through functional modeling with formal language tools and performance modeling with professional network performance evaluation tools, respectively. However, separate and duplicated modeling of a system may cause increase of the cost and inconsistency between the models. In order to overcome this problem, this paper proposes an integrated design technique that estimates the performance of a communication protocol designed in SDL with SDL-OPNET co-simulation. The proposed technique presents how to design a co-simulation system with the environment functions of Tau and the external system module of OPNET. InRes protocol was used as an example to show the applicability and usefulness of the proposed technique.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Development and Performance Evaluation of an Image Detection System for Efficient 4D Images (효율적인 4D 영상을 위한 영상 검출 시스템 개발 및 성능평가)

  • Cho, Kyoung-Woo;Liu, Ze-Qi;Jeon, Min-Ho;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.792-797
    • /
    • 2013
  • 4D film is just a film that made by adding some physical effects to 3D film or general film. In order to provide physical effects to the audience, the data that make the physical effect must be added to each frames. In this paper, we proposed a video detection system that can efficiently provide physical effects by assessing the present situation such as explosion scene, snowing scene. The proposed video detection system contains an algorithm for fire detection by using R color and $C_r$ value, and also an algorithm for snow detection by using RGB color model. The system constitutes in a MCU that from 8051 family. In the performance evaluations, the result shows that 91% of detection rate in case of fire and 25% of false detection rate in case of snow. Also the system is capable of providing physical effects automatically.

Study for Diagnostic Correspondent Rates between DSOM and Oriental Medical Doctors (한방진단시스템과 진단의 간의 진단일치도 연구)

  • Lee, In-Seon;Lee, Yong-Tae;Chi, Gyoo-Yong;Kim, Jong-Won;Kim, Kyu-Kon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1359-1367
    • /
    • 2008
  • DSOM(Diagnosis System of Oriental Medicine) was made as a computerized assistant program for oriental medicine doctors to be able to diagnose with statistical basis. Then DSOM uses questionnaires filled out by subjects without enough explanatory guide. If the subject misunderstand the meaning of the passages, we might not rely on that result. So I designed this study to investigate the diagnostic correspondent rates between DSOM and practitioners. First, let the respondents answer to DSOM(DSOM-Ⅰ for the rest). After that, three doctors diagnosed the respondents and marked how much they had symptoms about 16 pathogenic factors in the score range 0${\sim}$5('0' means they didn't have that symptom, '1' means they had that symptom but mild, '3' means they had that symptom moderately, '5' means they had that symptom severely. And let the respondents answer to DSOM(DSOM-Ⅱ for the rest) again. Finally, we investigated the correspondent rates of diagnosis between DSOM-Ⅰ,Ⅱ and doctors'. We obtained conclusions as following. In the comparison of output frequency rate of the pathogenic factors, the difference between DSOM-Ⅰ and Ⅱ was 1%. In the correspondent rates of diagnosis between DSOM-Ⅰ,Ⅱ and doctors', In DSOM-Ⅰ and Ⅱ answered by subjects two times respectively, the correspondent rate was highest in insufficiency of Yang(陽虛) and liver(肝) as 93.2%, lowest in damp(濕) as 69.5% and showed 81.9% in all 16 pathogenic factors mean. In DSOM-Ⅰ and Ⅱ, and Doctors' diagnose, they showed the complete correspondent rates of 15.3${\sim}$61.0%, 15.3${\sim}$59.3% in individual pathogenic factor, 36.5%, 37.3% in all 16 pathogenic factors mean each, and within ${\pm}$1 errorrange, they showed the correspondent rates of 32.2${\sim}$93.2%, 35.6${\sim}$89.8% in individual pathogenic factor, 67.6%, 67.3% in all 16 pathogenic factors mean each, and within ${\pm}$2 error range, they showed the correspondent rates of 62.7${\sim}$98.3%, 71.2${\sim}$100% in individual pathogenic factor, 85.1 87.6%% in all 16 pathogenic factors mean each. In the correspondent rates of the severe case, In the cases that the Doctors' diagnostic score mean was over 3(the severity of disease is middle), there were deficiency of qi(氣虛), stagnation of qi(氣滯), blood stasis(血瘀), damp(濕), liver(肝), heart(心), spleen(脾) and they all showed the correspondent rates of over 60 except blood stasis(血瘀). In the cases that the weighed pathogenic factor was above 9, the correspondent rates were 50${\sim}$100%. deficiency of qi(氣虛), blood-deficiency(血虛), stagnation of qi(氣滯), blood stasis(血瘀), insufficiency of Yin(陽虛), insufficiency of Yang(陽虛), coldness(寒), heat (熱), damp(濕), dryness(燥), liver(肝), heart(心), spleen(脾), kidney(腎), phlegm(痰).

Design of Oriental Medicine diagnosis system by Bio-Electric Response (생체-전기적 반응에 의한 한의학적 진단시스템의 설계)

  • 이용흠;장근중;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.420-429
    • /
    • 2004
  • It has been needed diagnosis technology of the EFG(Electro Functio Gram) measurement concept which is incorporated characteristic of modern science and biomedical engineering, because function abnormality diagnosis can't diagnose with visualization instruments or clinical pathology. The general diagnosis system(EFG system) has been developed to use basic diagnosis instrument that has reappearance, reliance and convenience using the functio diagnosis technology, in the field of western/oriental medicine. Also, we improved sticking electrode and simultaneous measurement method of the limbs 8CH, head 2CH to diagnose body circulation of Qi and acupoints for Oriental Medicine diagnosis/therapy. The result of clinical for adult man 20 persons, the EFG system can diagnose state of 12 meridians and autonomic nervous system. Therefore, in this paper, we designed of oriental medicine diagnosis system by bio-electric response with materialized H/W and S/W for 12 meridians state diagnosis of human body and system construction of the EFG.