• 제목/요약/키워드: QRS

검색결과 264건 처리시간 0.047초

ECG 진단을 위한 QRS 검출 알고리즘 (QRS Detection Algorithm for ECG Analysis)

  • 홍성호;김영섭;이명석;노학엽;지용석
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.57-61
    • /
    • 2012
  • In order to analyze the ECG, it is important to pinpoint the repeat interval of the ECG. In this paper, we present an efficient algorithm for finding the QRS complex on the ECG. We escaped from the conventional methods to go through multiple steps of preprocessing to make ECG easier to find the QRS complex. We selected the candidate peak that has the possibility of the QRS complex in original ECG, and used technique to find the QRS complex among the candidate peak. In this way, we could get similar efficiency to Pan & Tompkins Algorithm that is most representative QRS complex detection algorithm, just used fewer operations than Pan & Tompkins Algorithm.

The change of QRS duration after pulmonary valve replacement in patients with repaired tetralogy of Fallot and pulmonary regurgitation

  • Yun, Yuni;Kim, Yeo Hyang;Kwon, Jung Eun
    • Clinical and Experimental Pediatrics
    • /
    • 제61권11호
    • /
    • pp.362-365
    • /
    • 2018
  • Purpose: This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF). Methods: Children and adolescents who had previously undergone total repair for TOF (n=67; median age, 16 years) who required elective PVR for pulmonary regurgitation and/or right ventricular out tract obstruction were included in this study. The QRS duration and CTR were measured pre- and postoperatively and postoperative changes were evaluated. Results: Following PVR, the CTR significantly decreased (pre-PVR $57.2%{\pm}6.2%$, post-PVR $53.8%{\pm}5.5%$, P=0.002). The postoperative QRS duration showed a tendency to decrease (pre-PVR $162.7{\pm}26.4$ msec, post-PVR $156.4{\pm}24.4$ msec, P=0.124). QRS duration was greater than 180 msec in 6 patients prior to PVR. Of these, 5 patients showed a decrease in QRS duration following PVR; QRS duration was less than 180 msec in 2 patients, and QRS duration remained greater than 180 msec in 3 patients, including 2 patients with diffuse postoperative right ventricular outflow tract hypokinesis. Six patients had coexisting arrhythmias before PVR; 2 patients, atrial tachycardia; 3 patients, premature ventricular contraction; and 1 patient, premature atrial contraction. None of the patients presented with arrhythmia following PVR. Conclusion: The CTR and QRS duration reduced following PVR. However, QRS duration may not decrease below 180 msec after PVR, particularly in patients with right ventricular outflow tract hypokinesis. The CTR and ECG may provide additional clinical information on changes in right ventricular volume and/or pressure in these patients.

효율적인 QRS 검출과 프로파일링 기법을 통한 심실조기수축(PVC) 분류 (Efficient QRS Detection and PVC(Premature Ventricular Contraction) Classification based on Profiling Method)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.705-711
    • /
    • 2013
  • 심전도 신호의 QRS 영역은 심장의 질환을 판단하는 중요한 자료로 쓰이는데, 여러 종류의 잡음으로 인해 이를 분석하는데 어려움을 준다. 또한 일반인들의 건강상태를 지속적으로 모니터링 하는 헬스케어 시스템에서는 신호의 실시간 처리가 필요하다. 그리고 생체신호의 특성상 개인 간의 차이가 있음에도 불구하고, 일반적인 ECG 신호의 판단 규칙에 따라 진단을 수행함으로써 성능하락이 나타날 수밖에 없다. 이러한 문제점을 해결하기 위해서는 최소한의 연산량으로 QRS를 검출하고 환자의 특성에 맞게 부정맥을 분류할 수 있는 알고리즘의 설계가 필요하다. 따라서 본 연구에서는 형태연산을 통한 효율적인 QRS 검출과 개인별 정상신호 분류를 위해 해쉬 함수를 적용하여 프로파일링 하였으며, 검출된 QRS 폭과 RR 간격을 이용하여 심실조기수축(PVC)을 분류하는 알고리즘을 개발하였다. 제안한 방법의 우수성을 입증하기 위해 MIT-BIH 부정맥 데이터베이스를 통해 기존 방법과 부정맥 분류 성능을 비교하였다. 성능평가 결과, R파는 평균 99.77%, 정상 신호 분류에 대한 에러율은 0.65%, PVC는 각각 93.29%로 기존 방법에 비해 약 5% 우수하게 나타났다.

사군자탕(四君子湯) 및 사물탕(四物湯)이 인체파동(人體波動)과 활성산소(活性酸素)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (Study on the effect of Sagunjatang(SGJT) and Samultang(SMT) extract on the Wave of Human body and Active Oxygen)

  • 조기용;유동열
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.305-317
    • /
    • 2000
  • To prove the effect of Sagunjatang(SGJT) and Samultang(SMT) extract on the wave of Human Body and Active Oxygen experimentally, QRS & Free Radical of extract and precipitate of SGJT and SMT was measured. The results were summarized as follows ; 1. SGJT extract and precipitate, as a result of measuring QRS and Free Radical, had a considerable effect on the function of immunity & pituitary gland. 2. BaekBokRung of SGJT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of heart & spleen. 3. BaekChul and Gamcho of SGJT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of stomach & duodenum. 4. YinSam of SGJT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of immunity & spleen. 5. SMT extract and precipitate, as a result of measuring QRS and Free Radical, had a considerable effect on the function of immunity & uterus. 6. SukJiHwang of SMT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of immunity & liver. 7. DangGui of SMT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of heart & spleen. 8. ChunGung of SMT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of spleen & pituitary gland. 9. BaekJakYak of SMT, as a result of measuring QRS and Free Radical, had a considerable effect on the function of stomach & duodenum. 10. SMT extract had an effect on the function of female Urogenital system, SGJT extract had an effect on the function of male Urogenital system. These results suggested that SGJT and SMT extract might be usefully applied for suppresing of Active Oxygen formation, preventing the aging, curing all the disease resulted from Active Oxygen.

  • PDF

Real-Time QRS Detection Using Wavelet Packet Transform

  • Bholsithi, Wisarut;;Hinjit, Watcharapong;Dejhan, Kobchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1880-1884
    • /
    • 2004
  • The wavelet packet transform has been applied for QRS detection with squaring, window integration, and impulse filter techniques to cut down the false detection of QRS complex. This real time QRS detection has been performed on Simulink and Matlab. The correct QRS detection rates have reached to 99.75% in the experiment with 15 sets of ECG data from European ST-T database which are kept in Physionet.

  • PDF

이산 웨이블릿 변환을 이용한 QRS군 검출 알고리즘 최적화 (Optimization of a QRS complex Detection Algorithm Using Discrete Wavelet Transform)

  • 이근상;백용현;박영철
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.45-50
    • /
    • 2010
  • 본 논문에서는 운동 중 실시간 구현을 위해 정확한 QRS 검출이 가능한 이산 웨이블릿 연산을 임펄스 응답으로 근사화 하여 연산량을 줄였다. 또한, 지속적인 QRS 검출로부터 부정맥, 빈맥 그리고 서맥등의 정보를 제공한다. 제안 알고리듬은 운동 중 수집된 생체신호를 컴퓨터 시뮬레이션을 통해 평가한다.

  • PDF

심전도 자동 진단을 위한 QRS 파형의 분류 (QRS classification for automated ECG diagnosis)

  • 전대근;염호준;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.410-413
    • /
    • 1997
  • The most important wave set in ECG is the QRS complex. Automatic classification of the QRS complex is very useful in the diagnosis of cardiac dysfunction. Also, diagnosis is influenced by selection of dominant beat. In this paper, we propose simple algorithm for QRS detection. And we determine correlation between significan attributes of QRS complexs. We evaluated the efficiency of proposed method with the CSE database.

  • PDF

M 채널 필터 뱅크를 이용한 QRS complex 검출 알고리즘 (QRS Complex Detection Algorithm Using M Channel Filter Banks)

  • 김동석;전대근;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권2호
    • /
    • pp.165-174
    • /
    • 2000
  • 본 논문에서는 M 채널 필터 뱅크를 이용하여 심전도 자동 진단 시스템에서 매우 중요한 파라미터로 사용되는 QRS complex 검출을 실시하였다. 제안된 알고리즘에서는 심전도 신호를 M개의 균일한 주파수 대역으로 분할(decomposition)하고, 분할된 서브밴드(subband) 신호들 중에서 QRS complex의 에너지 분포가 가장 많이 존재하는 5∼25Hz 영역의 서브밴드 신호들을 선택하여 feature를 계산함으로써 QRS complex 검출을 실시하였다. 제안된 알고리즘의 성능 비교를 위하여 MIT-BIH arrhythmia database를 사용하였으며, sensitivity는 99.82%, positive predictivity는 99.82, 평균 검출율은 99.67%로 기존의 알고리즘에 비해 높은 검출 성능을 나타내었다. 또한 polyphase representation을 이용하여 M 채널 필터 뱅크를 구현한 결과 연산 시간이 단추되어 실시간 검출이 가능함을 확인하였다.

  • PDF

개인별 이상신호 검출과 QRS 패턴 변화에 따른 조기심실수축 분류 (PVC Classification by Personalized Abnormal Signal Detection and QRS Pattern Variability)

  • 조익성;윤정오;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제18권7호
    • /
    • pp.1531-1539
    • /
    • 2014
  • 조기심실수축(PVC)은 가장 보편적인 부정맥으로 심실세동, 심실빈맥 등과 같은 위험한 상황을 유발할 수 있는 가능성을 가지고 있기 때문에 이의 조기 검출은 매우 중요하다. 하지만 ECG 신호의 개인 차이가 있음에도 불구하고, 일반적인 신호의 판단 규칙에 따라 진단을 수행함으로써 성능하락이 나타날 수 밖에 없다. 이러한 문제점을 극복하기 위해서는 개인에 따른 이상 신호를 검출한 후 다양한 QRS 패턴을 고려하여 PVC를 분류할 수 있는 알고리즘이 필요하다. 본 연구에서는 개인별 이상신호 검출과 QRS 패턴 변화에 따른 PVC 분류 기법을 제안한다. 이를 위해 전 처리 과정과 차감기법을 통해 R파를 검출하였으며, 개인별 이상신호를 검출하였다. 이후 QRS 패턴에 따른 QS 간격과 R파의 진폭 변화율에 따라 PVC를 분류하였다. 제안한 알고리즘의 이상 신호 검출 및 PVC 분류 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, 이상 신호 검출률은 98.33%, PVC는 각각 94.46%의 평균 분류율을 나타내었다.

웨이블릿을 이용한 QRS complex 검출 알고리즘의 고정 소수점 연산 최적화 (Fixed-point Optimization of a QRS complex Detection Algorithm Using Wavelet Transform)

  • 박영철
    • 한국정보전자통신기술학회논문지
    • /
    • 제7권3호
    • /
    • pp.126-131
    • /
    • 2014
  • 본 논문에서는 웨이블릿 변환을 통하며 QRS complex를 검출 하며, 32비트 고정 소수점 연산이 가능한 프로세서에도 동작하도록 알고리즘 최적화 기법을 제시한다. 먼저 입력 ECG 신호를 밴드 패스 필터를 통과 시키고, 3개의 서로 다른 웨이블릿 함수를 하나로 병합한 웨이블릿 함수를 이용하여 웨이블릿 변환을 하며, 다음으로 시간 평균 함수를 뒤에 마지막으로 QRS complex를 검출 한다. 제안 알고리즘은 MIT-BIH arrhythmia database에 적용하여 검증한다. 모든 과정은 32비트 고정 소수점 연산으로 구현되며, 삼각함수 같은 복잡한 연산은 테이블화 하였다. 검출 알고리즘은 컴퓨터 시뮬레이션을 통해 평가 한다.