• Title/Summary/Keyword: QA/QC

Search Result 91, Processing Time 0.026 seconds

Improvement of the Marine Environmental Assessment for Dredging and Ocean Disposal of Coastal Sediment in Korea (연안준설 및 준설토 해양투기 해양환경평가 개선방안)

  • Lee, Dae-In;Park, Dal-Soo;Eom, Ki-Hyuk;Kim, Gui-Young;Cho, Hyeon-Seo;Kim, Jong-Kyu;Seo, Young-Kyo;Baeck, Gun-Wook
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.3
    • /
    • pp.131-141
    • /
    • 2009
  • We studied improvement in marine environmental impact assessment and related management systems of coastal sediments that are dredged inshore but disposed offshore. After reviewing and diagnosing the existing assessment procedures and problems, we recommend to design the core assessment items and improve the reliability of assessment byenhancing the quality assurance/quality control (QA/QC) and verification processes. We proposed eco-friendly disposal plan for dredging sediment such as reuse system in land development was explored. A marine environmental database system was established to support the assessment processes. Guidelines for marine research and modelling were proposed for improving assessment of dredging and disposal of coastal sediment. Also, applying of screening and scoping for marine environmental assessment was reviewed.

Proposal of Standard Method for the Analysis of Polycyclic Aromatic Hydrocarbons in Marine Sediments (해양퇴적물내 다환방향족탄화수소 분석을 위한 표준작업절차서 제안)

  • Lee, Hyo-Jin;Kim, Gi-Beum;Choi, Yoon-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.3
    • /
    • pp.163-175
    • /
    • 2011
  • Though polycyclic aromatic hydrocarbon compounds (PAHs) in marine sediment has been produced by many colleges and institution in Korea, it is difficult to compare PAHs data in a study area with those in other areas due to the lack of confidence for the quality of data from the other organization. Therefore, we suggested the protocol for PAHs analysis in marine sediment through examining the method of PAHs analysis described in over twenty scientific papers and reports. When a known amount of 23 PAHs were spiked into a sediment and anlyzed following this new protocol, very good recoveries were obtained. In addition, for college and institution with their own method to analyze PAHs can keep producing PAHs data without exchanging to this new PAHs protocol, the method to get a full confidence through the QA/QC for the PAHs data produced by these organization is included to the protocol.

Construction Management Method for Asphalt Paving Using Ground Penetrating Radar and an Infrared Camera (지표투과레이더와 적외선카메라를 이용한 아스팔트 포장 시공 관리 방법)

  • Baek, Jongeun;Park, Hee Mun;Yoo, Pyung Jun;Im, Jae Kyu
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.1-9
    • /
    • 2015
  • PURPOSES : The objective of this study is to propose a quality control and quality assurance method for use during asphalt pavement construction using non-destructive methods, such as ground penetrating radar (GPR) and an infrared (IR) camera. METHODS : A 1.0 GHz air-coupled GPR system was used to measure the thickness and in situ density of asphalt concrete overlay during the placement and compaction of the asphalt layer in two test construction sections. The in situ density of the asphalt layer was estimated based on the dielectric constant of the asphalt concrete, which was measured as the ratio of the amplitude of the surface reflection of the asphalt mat to that of a metal plate. In addition, an IR camera was used to monitor the surface temperature of the asphalt mat to ensure its uniformity, for both conventional asphalt concrete and fiber-reinforced asphalt (FRA) concrete. RESULTS : From the GPR test, the measured in situ air void of the asphalt concrete overlay gradually decreased from 12.6% at placement to 8.1% after five roller passes for conventional asphalt concrete, and from 10.7% to 5.9% for the FRA concrete. The thickness of the asphalt concrete overlay was reduced from 7.0 cm to 6.0 cm for the conventional material, and from 9.2 cm to 6.4 cm for the FRA concrete. From the IR camera measurements, the temperature differences in the asphalt mat ranged from $10^{\circ}C$ to $30^{\circ}C$ in the two test sections. CONCLUSIONS : During asphalt concrete construction, GPR and IR tests can be applicable for monitoring the changes in in situ density, thickness, and temperature differences of the overlay, which are the most important factors for quality control. For easier and more reliable quality control of asphalt overlay construction, it is better to use the thickness measurement from the GPR.

Citizen Volunteer Monitoring as a Tool for Environmental Education (민간환경감시활동을 통한 환경교육)

  • Gang, Seong-Hyeon;Kim, Eun-Hui;Sin, Jong-Won
    • Hwankyungkyoyuk
    • /
    • v.10 no.2
    • /
    • pp.311-324
    • /
    • 1997
  • General citizens can be a valuable resource for various types of environmental monitoring when they are well-trained and managed. Successful use of volunteer monitors depends on understanding that citizens are partners sharing expanded roles as the guardians of their local environment. Citizen volunteer monitoring programs are developed for three reasons: 1) to supplement environmental data collected by professional staffs in governmental agencies and scientific institutions; 2) to educate the public about local environmental problems; 3) to build a constituency of citizen to practice sound environmental management at a local level and build public support for environmental protection. All three goals can be achieved with a well-organized program which provides useful and credible data. Initial step in planning a successful volunteer monitoring project is to clearly identify the use to be made of the data. Technical advice from the identified potential user groups should be convened early in the planning stage to refine the program objectives and determine if volunteers can provide the level of expertise required. Data users must have confidence in the representativeness, consistency, and accuracy of data collected by volunteers. Effective quality assurance and quality control(QA/QC) procedures are essential to ensure the utility of environmental monitoring data. Volunteers must be trained in advance to carry out specific environmental monitoring tasks. Another components of successful volunteer monitoring programs is to give the volunteers praise and feedback as well as to encourage experienced volunteers to impose increased responsibilities. The increase of volunteer monitoring programs in Korea will play a major role in developing a participatory system in which the people are "empowered" to make decisions and make a difference.

  • PDF

Introduction to CM Experience from Incheon International Airport (IIA) Construction Project (인천국제공항건설 사업관리 경험)

  • Park, Dae-Won
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.20-25
    • /
    • 2004
  • On July $18^{th}$, 2003, Incheon International Airport Corporation(lIAC) signed the Construction Management Service Contract with KIDS consortium (composed of Kun-Won Eng., ITM Corp, Do-Hwa Eng, Space Croup) for the $2^{nd}$ phase construction protect consists of landfill, $\#3$ runway, remote Concourse, IAT, BHS, cargo terminal, etc scheduled to be finished by the end of 2008. KIDS dispatched qualified engineers to the Construction Management Division of IIAC for providing technical assistance to IIAC members to pursue project goals in tulle. within budget with appropriate quality level to build one of leading hul] airports for the Northeast Asia legion in the $21^{st}$ century. The work scope covers upgrading various project procedures and related computer programs, cost and schedule control, design supervision for building design including support systerns such as HVAC, fire protection, elevators and escalators, boarding bridges, electrical and communication systems, and technical support for IAT/BHS, QA/QC, field test and inspection, start-up and commissioning, etc. The purpose of this paper is to introduce the major activities of the Construction Management Services performing at the IIA project for your reference.

  • PDF

Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere - Focusing on High Volume Sampling and GC/MS Analysis (대기 중 다환방향족탄화수소 측정방법의 성능평가 - 하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로)

  • Seo, Young-Kyo;Park, Dae-Kwon;Baek, Sung-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.322-333
    • /
    • 2009
  • In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on $8"{\times}10"$ quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.

Improvement of Marine Environmental Impact Assessment for Golf Course Projects in Southern Coastal Area of Korea (남해연안 골프장조성에 따른 해양환경영향평가 개선방안)

  • Kim, Gui-Young;Lee, Dae-In;Yu, Jun;Eom, Ki-Hyuk;Jeon, Kyeong-Am
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.5
    • /
    • pp.453-464
    • /
    • 2010
  • We evaluated the status and problems of golf course developments in the southern coast of Korea. It's adjacent waters supports nursery and fishing grounds for commercially-important fisheries species, and various sites are designated and protected as marine protection area(MPA), fisheries reserve, or clean area(blue belt) for producing shellfish. We proposed key assessment items for environmental impact assessment(EIA) and checklists in selecting golf course locations. For the protected areas, we suggest that it is essential to limit golf course establishment while setting a minimal distance from the coast to secure a buffer zone for mitigating the environmental impacts. To efficiently utilize existing regional coastal management plans, it is necessary to diagnose how a golf course development will potentially modify geomorphology and scenery, amplify pollutant loads from non-point sources, and disrupt the functions of coastal ecosystem. Especially, continued monitoring and assesssing input loads of hazardous materials originating from agricultural chemicals should be obligatory. Finally, measures for improving the QA/QC analysis were discussed to enhance reliability of environmental data with respect to golf courses and adjacent coastal waters.

Quantitative Analysis and Comparison of DR and CR image quality (CR과 DR 영상화질의 정량적 비교분석)

  • Park, Hey-Suk;Seo, Jang-Yeon;Jeong, Jin-Hwa;Lee, Chang-Lae;Cho, Hyo-Min;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • The purpose of this research was to compare and analyze image quality for each Detector of CR(Computed Radiography) and DR(Digital Radiography). The results showed that CR(AGFA MD 4.0 General plate, JAPAN) was superior to DR(HOLOGIC nDirect Ray, USA) based on the quantitative values and comparison of MTF(Modulation Transfer Function), NPS(Noise Power Spectrum), Photon fluence and DQE(Detective Quantum Efficiency) which have been widely accepted for the estimation of CR and DR. Quantitative evaluations of CR and DR system were obtained and they may be very helpful for QA and QC of general X-ray systems.

  • PDF

Monitoring of Brominated Flame Retardants (BFRs) for the management of Their Contamination in Environments (브롬화 난연제의 환경오염도 관리 방안)

  • Kim, Yong-Bum;Lee, Sang-Hoon;Chung, Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.2
    • /
    • pp.83-96
    • /
    • 2005
  • Brominated flame retardants have the market share of 40%, comparing others because of their low cost and highly effective retardation against the flame. However, their toxic effects in human and properties of the accumulation in the environments have been issued among the international organization such as EU, OECD and etc. It, therefore, was surveyed the classification, toxic effects, and the usage of Brominated flame retardants, the trends for their managements in the world and Korea, and their contaminated levels in Korean Peninsula. In addition, the management directions for them were proposed. Penta, octa, and deca-BDE among brominated retardants will seem to be prohibited by the regulation as a flame retardants for plastics in Europe because of their toxic effects. Although Penta and Octa BDEs was used marginally in Korea, deca-BDE was 27% of brominated flame retardants (49,050 ton) which had been used in 2002. However, risk assessment for brominated retardants might not launched in Korea, yet. These reports demonstrate that toxic brominated retardants such as PBDEs will be assessed for their usage and the level of contamination in the environment in the area of the point sources like the industrial areas, incinerators and etc. However, the law to regulate the hazardous chemicals seems not to be dictated the monitoring of their contamination in the environment. We, therefore, suggest how to evaluate and to monitor the toxic contaminants with EIA (Environmental Impact Assessment) and LCA (Life Cycle Assessment) system. Further, to establish the management system of BFRs (such as the monitering of contamination levels in environments, life cycle assessment, and risk assessment for the toxic chemicals), It can be recommended the law to deal with the method analyzing chemicals will be established, which contains QA/QC (Quality Assurance and Quality Control) to evaluate the analytic capability of the companies to prepare EIS (Environment Impact Statement) or other institutes for analyzing chemicals.

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF