• Title/Summary/Keyword: Q420

Search Result 30, Processing Time 0.029 seconds

Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression

  • Shi, G.;Liu, Z.;Ban, H.Y.;Zhang, Y.;Shi, Y.J.;Wang, Y.Q.
    • Steel and Composite Structures
    • /
    • v.12 no.1
    • /
    • pp.31-51
    • /
    • 2012
  • Local buckling can be ignored for hot-rolled ordinary strength steel equal angle compression members, because the width-to-thickness ratios of the leg don't exceed the limit value. With the development of steel structures, Q420 high strength steel angles with the nominal yield strength of 420 MPa have begun to be widely used in China. Because of the high strength, the limit value of the width-to-thickness ratio becomes smaller than that of ordinary steel strength, which causes that the width-to-thickness ratios of some hot-rolled steel angle sections exceed the limit value. Consequently, local buckling must be considered for 420 MPa steel equal angles under axial compression. The existing research on the local buckling of high strength steel members under axial compression is briefly summarized, and it shows that there is lack of study on the local buckling of high strength steel equal angles under axial compression. Aiming at the local buckling of high strength steel angles, this paper conducts an axial compression experiment of 420MPa high strength steel equal angles, including 15 stub columns. The test results are compared with the corresponding design methods in ANSI/AISC 360-05 and Eurocode 3. Then a finite element model is developed to analyze the local buckling behavior of high strength steel equal angles under axial compression, and validated by the test results. Following the validation, a finite element parametric study is conducted to study the influences of a range of parameters, and the analysis results are compared with the design strengths by ANSI/AISC 360-05 and Eurocode 3.

A Study on vector control of induction motor drive using a speed sensorless (속도센서리스 벡터제어에 의한 유도전동기 운전)

  • 이춘상
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.417-420
    • /
    • 2000
  • In order to the torque control the indirect flux control was performed by controlling the ratio of e/f and the q-axis flux was estimated by the slip command and q-axis flux was estimated by the slip command and q-axis current in the rotor circuits. Also the frequency was controlled to keep on the q-axis flux to be zero and the constant torque characteristics could be obtained by generation the preset torque. In the induction motor driven by the boltage source inverter with the constant voltage and frequency the speed variation is expressed as a slip So the speed control can be achieved by slip compensation The slip was calculated with a q-flux current filtered by first-order filter and as the result the error problem which may occur in current detection was eliminated

  • PDF

THE DEVELOPMENT OF Q-BAND HEMT RECEIVER FOR VLBI (VLBI용 Q-band HEMT 수신기 개발)

  • 제도홍;한석태;김태성;김현주;김광동;정문희;이창훈;노덕규
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.1
    • /
    • pp.29-38
    • /
    • 2004
  • A ultra low noise Q-band HEMT receiver for VLBI has been developed using a local oscillator with a very high phase stability. The performance of receiver was verified by comparison with receivers which were developed at the other countries. The receiver noise temperature shows 65 K in the frequency ragne from 42 ㎓ to 44 ㎓, less than 100 K from 39 ㎓ to 46 ㎓, respectively. A receiver noise temperature at SiO major line of 43㎓ which will be mainly observed by using this receiver has been optimized.

Thermal Decomposition Characteristics of Azo compounds (아조(Azo)화합물 열분해특성)

  • Kim, Kwan-Eung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • This study was investigated the thermal decomposition characteristics of azo type sponge blowing agent azodicarbonamide(ADCA) using differential scanning calorimeter(DSC). The experimental results showed that the exothermic onset $temperatures(T_{o})$ for ADCA were about $201{\sim}206^{\circ}C$ and evolution heats(Q) were about $144{\sim}150cal/g$. The exothermic onset $temperatures(T_{o})$, exothermic maximum $temperature(T_{m})$ and exothermic final $temperature(T_{f})$ were decreased by decreasing particle size of ADCA and evolution heats(Q) were increased with it. $T_{o}$ and Q for $6.1{\sim}7.2{\mu}m$ ADCA were increased by increasing heating rate at constant sample weight and activation energy was about 37.29kcal/mol. A positive gas pressure was employed in the elucidation of the decomposition behavior of ADCA because it sublimes during linear heating at atmospheric pressure. $T_{o}$ and Q of ADCA tended to increase with a pressure in air or nitrogen. In the case of azo dye, experimental results showed that $T_{o}$ were about $280{\sim}420^{\circ}C$ and Q were about $2{\sim}30cal/g$.

SUPERSTRUCTURES OF Bi-Sr-Ca-Cu-O SUPERCONDUTORS (Bi-Sr-Ca-Cu-O계열 초전도체의 초구조)

  • Nam, Gung-Chan;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.268-279
    • /
    • 1994
  • The x-ray powtler pattern of single phase $Bi_2S_2CaCu_2O_{8+x}$ has been identified and fullyindexed using a pseudotetragonal subcell with a= 5.408, c = 30.83 $\AA$ and an incommensurate supercellwith reciprocal lattice vector, X$q^*$, given by $q^*=0.211b^*-c^*$. The x -ray powder pattern of the Pb-free110K superconductor phase "$Bi_2S_2CaCu_2O_{10+x}$" has many lines which belong t.o an incommensuratesupercell. Using elect.ron d~ffraction pImt.ographs as a indexing guide, an indexing scheme for the powderpattern has been obtained. The unit cell has a geometrically orthorhombic subcell a=5.411, b= 5.420, c=37.29(2) $\AA$. Supercell reflections have indices that are derived from the subcell k, 1 indices by addition uf$\pm q^*$, where $\pm q^*=0.211b^*-0.78c^*$The incommensurate con~ponent In the b dwection, $\delta$, is the same for both phases but on going from2212 to 2223 phase, the superlattic component in the c direction changes from commensurate($\varepsilon$=1) toincommensurate($\varepsilon$=0.78).X>$\varepsilon$=0.78).

  • PDF

Effect of coenzyme Q10 and Ardisia japonica Blume on plasma and liver lipids, platelet aggregation, and erythrocyte Na efflux channels in simvastatin-treated guinea pigs

  • Kang, Min Sook;Yang, Hun Mo;Kang, Ja Young;Ryou, Sung Hee;Kang, Jung Sook
    • Nutrition Research and Practice
    • /
    • v.6 no.5
    • /
    • pp.414-420
    • /
    • 2012
  • Forty guinea pigs were divided into four groups and fed 0.04% cholesterol based control diet, plus 0.05% simvastatin, and statin plus 0.1% CoQ10 or 10% Ardisia Japonica Blume (AJB) leave powder for 4 weeks. Plasma total cholesterol levels decreased significantly in all groups fed the statin-containing diet compared with that in guinea pigs fed the control diet (P < 0.01). Plasma and liver triglycerides decreased significantly in the statin plus CoQ10 group compared with those in the control (both P < 0.05). Maximum platelet aggregation was significantly higher in the statin plus CoQ10 group than that in the other groups (P < 0.05). Na-K ATPase activity increased in the statin group and decreased in the statin plus CoQ10 group (P < 0.01). Na-K co-transport and Na passive transport decreased significantly in the control group compared with those in the other groups (both P < 0.05). Intracellular Na was highest in the statin group and lowest in the statin plus CoQ10 group and was correlated with Na-K ATPase activity. Thiobarbituric acid reactive substance production in platelet-rich plasma and liver tended to decrease in the statin plus CoQ10 group compared with those in the other groups. Plasma glutamic-pyruvic transaminase and glutamic-oxaloacetic transaminase increased significantly in the statin group compared with those in the control (P < 0.05). These result suggest that antioxidant rich AJB did not have positive effects on cardiovascular disease parameters. The statin plus CoQ10 seemed to decrease cholesterol more efficiently than that of statin alone.

Q-band MMIC Driver and Power Amplifiers for Wideband wireless Multimedia (Q-band 광대역 무선 멀티미디어용 MMIC구동 및 전력증폭기)

  • 강동민;이진희;윤형섭;심재엽;이경호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.167-170
    • /
    • 2002
  • The design and fabrication of Q-band 3-stage monolithic microwave integrated circuit(MMIC) driver and power amplifiers for WLAN are presented using 0.2${\mu}{\textrm}{m}$ AlGaAs/InGaAs/GaAs pseudomorphic high electron mobility transistor(PHEMT). In each stage of the MMIC DA, a negative feedback is used for both broadband and good stability. The MMIC PA has employed a balanced configuration to overcome these difficulties and achieve high power with low VSWR over a wide frequency range. In the MMIC DA, the measurement results arc achieved as an input return loss under -4dB, an output return loss under -l0dB, a gain of 14dB, and a PldB of 17dB at C-band(36~ 44GHz). The chip size is 28mm$\times$1.3mm. The developed MMIC PA has the l0dB linear gain over 360Hz to 420Hz band and 22dBm PldB performance at 400Hz. The size of fabricated MMIC PA is 4mm x3mm. These results closely match with design results. This MMIC DA Sl PA will be used as the unit cells to develop millimeter-wave transmitters for use in wideband wireless LAN systems.

  • PDF

Science and Technology Terminology Dictionary Building Process and Workbench Development in Defense Area (국방과학기술 전문용어 사전 구축을 위한 프로세스 및 워크벤치 개발)

  • Choi, Jung-Whoan;Park, Jeong-Ho;Kim, Kyung-Sun;Kim, Pyung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.420-428
    • /
    • 2012
  • To improve the efficiency of business, it is important to standardize the meaning of terminology. And then, terminology dictionaries have been actively being built and used in various fields. In defense area, the publication of defense terminology dictionary is useful for information exchange of each army and distribution of standardized terminology. Defense agency for technology and quality(DTaQ) publishes terminology dictionary of defense science and technology on a three-year cycle. DTaQ tries to standardize the construction process of terminology dictionary and improve service efficiency by using terminology dictionary in defense area. This proposed method is based on the result of previous study about standardization of terminology dictionary. We suggest the practical steps including terminology dictionary constructing process, composition and role of organization, definition of headword, selection of target documents to be extracted terminology candidate, terminology extraction, generation of terminology candidate group, workbench registration, construction and validation of terminology dictionary. Thesaurus and workbench are developed to use and support terminology dictionary effectively.