• Title/Summary/Keyword: Q factor

Search Result 1,369, Processing Time 0.031 seconds

A Study on Flow Characteristics of Branch Type Sparger in Drain Tank for Depressurization (감압용 배수탱크내의 분기형 증기분사기의 유동특성에 관한 연구)

  • 김광추;박만흥;박경석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.356-367
    • /
    • 2001
  • A numerical analysis on branch type sparger in drain tank for depressurization is performed to investigate the flow characteristics due to the change of design factor. As the result of this study, sparger\\`s flow resistance coefficient(K) is 3.53 at the present design condition when engineering margin for surface roughness is considered as 20%, and flow ratio into branch pipe ($Q_s/Q_i$) is 0.41. The correlation for calculating flow resistance coefficients as design factor is presented. Flow resistance coefficient is increased as section area ratio of branch pipe for main pipe and outlet nozzle diameter of main pipe decreasing, but the effects of branch angle and inlet flow rate of main pipe are small. As the change rate of ($Q_s/Q_i$)becomes larger, the change rate of flow resistance coefficient increases. The rate of pressure loss has the largest change as section area ratio changing. The condition of maximum flow resistance in sparger is when the outlet nozzle diameter ratio of main pipe ($D_e/D_i$) is 0.167, the section area ratio ($A_s/A_i$) is 0.1 and the branch angle ($\alpha$) is 55^{\circ}$.

  • PDF

The Characterization and Analysis of the simulated meander inductor for RF application (RF 응용을 위한 meander 인덕터의 특성 및 분석연구)

  • Kim, Sung-Hoon;Lee, Yong-Jun;Chang, Kun-Hyuk;Koh, Jung-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.352-352
    • /
    • 2008
  • 폐 자기회로 구조를 갖는 Meander 형태의 Inductor 설계를 위해 HFSS 프로그램을 이용하여 Meander Inductor를 시뮬레이션 하였다. Meander Inductor의 turn 수(N) 및 폭(W), 두께(T), 랩(G)의 변화에 따른 인덕턴스(L), S-parameter(S)와 Q-factor(Q)의 변화를 HFSS 를 통해 측정하였다. Al2O3 기판과 MgO의 두께는 각각 680um, 50um로 고정하였고, silver electrode를 이용하여 Meander 타입의 Inductor를 설계하였다. Meander Inductor의 turn수(6,7,8turn)의 변화를 측정한 결과, 8턴이었을 때 Q-factor가 19로서 가장 높은 결과를 얻었다. L의 결과 값은 공진 주파수와 의 관계에 의해 6turn일 때 L값은 17GHz에서 공진현상이 나타났다. 또한 W, G, T에 변화를 주어 설계한 뒤 시뮬레이션의 결과 값을 측정하였다. 그 값을 서로 비교한 결과, 변수들의 변화에 따라 L값과 Q-factor가 변화되었다. 이 논문에서는 각 변수에 따른 meander inductor의 특성을 HFSS 시뮬레이션을 통해 비교하고자 한다.

  • PDF

The study of optimization of restraint systems for injuries of Q6 and Q10 child dummies (Q6, Q10 어린이 인체모형 상해치에 대한 안전 구속 시스템 최적화 연구)

  • Sun, Hongyul;Lee, Seul;Kim, Kiseok;Yoon, Ilsung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.7 no.3
    • /
    • pp.7-13
    • /
    • 2015
  • Occupant protection performance in frontal crashes has been developed and assessed for mainly front seat occupants over many years, and in recent years protection of rear seat occupants has also been extensively discussed. Unlike the front seats, the rear seats are often occupied by children seated in rear-facing or forward - facing child restraint systems, or booster seats. In the ENCAP, child occupant protection assessments using 18-month-old(P1.5) and 3-year-old(P3) test dummies in the rear seat have already been changed to new type of 18-month-old (Q1.5)and 3-year-old(Q3) test dummies. In addition, ENCAP are scheduled with the development and introduction of test dummies of 6-year-old (Q6) and 10.5-year-old children(Q10) starting 2016. In KNCAP, Q6 and Q10 child dummies will be introduced in 2017 as well. Automobile manufacturers need to develop safety performance for new child dummies closely. In this paper, we focused on Q6 and Q10 child dummies sitting in child restraint system. Offset frontal crash tests were conducted using two types of test dummies, Q6 and Q10 child dummies, positioned in the rear seat. Q6 and Q10 were used to compare dummy kinematics in rear seating positions between Q6 behind the driver's seat and Q10 behind the front passenger's seat. The full vehicle sled test results of both dummies were conducted with different restraint systems. It showed that several injury and image data was collected as the result of the full vehicle sled test. Based on the results of these investigations, this paper describes which factor is most important and combination is the best performance when evaluating rear seat occupant protection for Q6 and Q10 child dummies.

Comparative Study for the Unloaded Quality Factors of High-Tc Superconductor-Dielectric Resonators Measured by Using S-parameter Circle-fit Method and Lorentzian-fit Method (S-parameter circle fit 방법과 Lorentzian fit 방법으로 측정된 고온초전도 유전체 공진기의 Unloaded Quality Factor 비교)

  • Kim, M.J.;Lee, J.H.;Park, E.K.;Yang, W.I.;Jung, H.S.;Choi, Y.O.;Lee, S.Y.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.143-151
    • /
    • 2007
  • Accurate measurements of the microwave surface resistance (Rs) of high temperature superconductor (HTS) films are important with regard to applications of HTS materials for wireless communications. As the surface resistance values of HTS films are usually extracted from the measured unloaded quality factor ($Q_0$) of resonators made of HTS films, it is essential to measure the resonator $Q_0$ with accuracy. The $TE_{011}\;mode\;Q_0$ of sapphire resonators with the endplates made of $YBa_2Cu_3O_{7-{\delta}}$(YBCO) film on $LaAlO_3$ is measured by using the S-parameter circle-fit method at a frequency of about 19.6 GHz and temperatures of 30 K to 90 K, which is compared with the measured values by using the Lorentzian-fit method. Good agreements are found between the two sets of $Q_0$ values measured by using the two different methods whether the resonator is used in a weak-coupling scheme or a strong-coupling scheme, showing reliability of both methods fur measuring the resonator $Q_0$ accurately. The $Q_0$ of sapphire resonators with a gap between the top plate and the rest of the resonator is also discussed.

  • PDF

Demonstration of MEMS Inductor on the LTCC Substrate (LTCC 기판위에 MEMS 인덕터 특성 연구)

  • Park, Je-Yung;Cha, Doo-Yeol;Kim, Sung-Tae;Kang, Min-Suk;Kim, Jong-Hee;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.12
    • /
    • pp.1049-1055
    • /
    • 2007
  • Lots of integration work has been done in order to miniaturize the devices for communication. To do this work, one of key work is to get miniaturized inductor with high Q factor for RF circuitry. However, it is not easy to get high Q inductor with silicon based substrate in the range of GHz. Although silicon is well known for its good electrical and mechanical characteristics, silicon has many losses due to small resistivity and high permittivity in the range of high frequency. MEMS technology is a key technology to fabricate miniaturized devices and LTCC is one of good substrate materials in the range of high frequency due to its characteristics of high resistivity and low permittivity. Therefore, we proposed and studied to fabricate and analyze the inductor on the LTCC substrate with MEMS fabrication technology as the one of solutions to overcome this problem. We succeeded in fabricating and characterizing the high Q inductor on the LTCC substrate and then compared and analyzed the results of this inductor with that on a silicon and a glass substrate. The inductor on the LTCC substrate has larger Q factor value and inductance value than that on a silicon and a glass substrate. The values of Q factor with the LTCC substrate are 12 at 3 GHz, 33 at 6 GHz, 51 at 7 GHz and the values of inductance is 1.8, 1.5, 0.6 nH in the range of 5 GHz on the silicon, glass, and LTCC substrate, respectively.

Soil CO2 efflux in a warm-temperature and sub-alpine forest in Jeju, South Korea

  • Jeong, Heon-Mo;Jang, Rae-Ha;Kim, Hae-Ran;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.41 no.6
    • /
    • pp.165-172
    • /
    • 2017
  • Background: This study investigated the temporal variation in soil $CO_2$ efflux and its relationship with soil temperature and precipitation in the Quercus glauca and Abies koreana forests in Jeju Island, South Korea, from August 2010 to December 2012. Q. glauca and A. koreana forests are typical vegetation of warm-temperate evergreen forest zone and sub-alpine coniferous forest zone, respectively, in Jeju island. Results: The mean soil $CO_2$ efflux of Q. glauca forest was $0.7g\;CO_2\;m^{-2}\;h^{-1}$ at $14.3^{\circ}C$ and that of A. koreana forest was $0.4g\;CO_2\;m^{-2}\;h^{-1}$ at $6.8^{\circ}C$. The cumulative annual soil $CO_2$ efflux of Q. glauca and A. koreana forests was 54.2 and $34.2t\;CO_2\;ha^{-1}$, respectively. Total accumulated soil carbon efflux in Q. glauca and A. koreana forests was 29.5 and $18.7t\;C\;ha^{-1}$ for 2 years, respectively. The relationship between soil $CO_2$ efflux and soil temperate at 10 cm depth was highly significant in the Q. glauca ($r^2=0.853$) and A. koreana forests ($r^2=0.842$). Soil temperature was the main controlling factor over $CO_2$ efflux during most of the study period. Also, precipitation may affect soil $CO_2$ efflux that appeared to be an important factor controlling the efflux rate. Conclusions: Soil $CO_2$ efflux was affected by soil temperature as the dominant control and moisture as the limiting factor. The difference of soil $CO_2$ efflux between of Q. glauca and A. koreana forests was induced by soil temperature to altitude and regional precipitation.

Recognition on Suicidal Intent of the Elderly among Caregivers: A Q-Methodological Application (노인 자살의도에 대한 주부양자의 인식: Q-방법론 적용)

  • Cho, Joon Ah;Kim, Boon Han
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.5
    • /
    • pp.522-532
    • /
    • 2014
  • Purpose: This study's purpose is to classify and analyze caregivers' recognition of the elderly suicidal intents. Methods: This study uses applied Q-methodology to measure human subjectivity in depth. Concretely, 35 statements are composed in depth interviews and literature investigation. Then, Q-cards and distributive chart of Q-sampling were given to 25 caregivers randomly-selected, who were asked to arrange them on a 7-score based. After coding Q-factor analysis is carried out with the PC-QUANL program. Results: Four types of indicators of the elderly suicidal intents were identified by the caregivers. These are Knowledge-based recognition, Behavioral measure based recognition, Negative comprehension and Sympathy. Conclusion: In this study, four types of recognition were yielded among the caregivers and the characteristics of each type were analyzed. These findings may be useful in assessing suicidal potential and nursing interventions.

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Piezoelectric properties of Pb-free BNKT ceramics with the amount of $La_2O_3$ addition ($La_2O_3$ 첨가에 따른 무연 BNKT세라믹의 압전 특성)

  • Lee, Hyun-Seok;Lee, Chang-Bae;Yoo, Ju-Hyun;Jeong, Yeong-Ho;Hong, Jael-Il;Chung, Kwang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.145-149
    • /
    • 2004
  • In this study, leed-free piezoelectric ceramics were investigated for pressure sensor applications as a function of the amount of $La_2O_3$ addition at BNKT system. With increasing amount of $La_2O_3$ addition, density and dielectric constant were increased up to 0.9wt% addition and decreased after 0.9wt% addition, electromechanical coupling factor$(k_p)$ and mechanical quality factor$(Q_m)$ showed the maximum values at 0.2wt% addition and decreased after 0.2wt% addition. The $k_p$, density, dielectric constant and $Q_m$ were showed the optimum values of 0.40, $5.71g/cm^3$, 768 and 118 at $La_2O_3$ 0.2wt% addition, respectively.

  • PDF