• Title/Summary/Keyword: Putty

Search Result 65, Processing Time 0.023 seconds

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

A Case Report of Guided Bone Regeneration Using a Putty-type Demineralized Bone Matrix (골유도재생술에 대한 putty형 탈회 기질골 이용연구)

  • Jeong, Mi-Ae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.330-333
    • /
    • 2011
  • Allomatrix (Wright Medical Tech, Inc., USA), is a newly designed, injectable putty with a reliable demineralized bone matrix(DBM), derived from human bone. The compound contains 86% DBM and other bone growth factors such as bone morphogenic protein (BMP)-2, BMP-4, insulin-like growth factor (IGF)-1, and transforming growth factor (TGF)-${\beta}1$. It has excellent os-teoinduction abilities. In addition, DBM is known to have osteoconduction capacity as a scaffold due to its collagen matrix. This product contains a powder, which is a mix of DBM and surgical grade calcium sulfate as a carrier. A practitioner can blend the powder with calcium sulfate solution, making a putty-type material which has the advantages of ease of handling, better fixation, and no need for a membrane, because it can function as membrane itself. This study reports the clinical and radiographic results of various guided bone regeneration cases using Allomatrix, demonstrating its strong potential as a graft material.

  • PDF

A comparision of TTSSH and Putty (TTSSH와 PUTTY의 비교 분석)

  • 강민정;강민수;박연식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.7
    • /
    • pp.1100-1105
    • /
    • 2002
  • As Unix based server including Linux are increased steadily, MS group users who want to connect these servers are increased. There were lots of connection using traditional network services like telnet or ftp for a long while, but connection using "TTSSH or PuTTY" which get used free have been increasing since “secure shell”(SSH) appeared. This paper compare TTSSH & PuTTY′s characters and using method, and propose remote-access tool which improve TTSSH for MS group users.

Comparison of the sealing ability of various bioceramic materials for endodontic surgery

  • Benjamin Rencher ;Ana M. Chang ;Hanson Fong;James D. Johnson;Avina Paranjpe
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.35.1-35.11
    • /
    • 2021
  • Objectives: Endosequence Bioceramic Root Repair Material (BC-RRM) is used in endodontic microsurgery. It is available as a paste and a putty. However, no studies to date have examined the sealing ability of these forms alone or in combination as root-end filling materials. Hence, this study aimed to compare the sealing properties of these 2 forms of BC-RRM. Materials and Methods: Forty-two extracted upper anterior teeth were divided into 3 experimental groups, a positive and negative control. After the root canal treatment, the root ends were resected, retroprepared and retrofilled with either putty, paste + putty or mineral trioxide aggregate (MTA). The teeth were mounted in tubes so the apical 3 mm was submerged in Brain Heart Infusion (BHI) broth. The coronal portions of the canals were inoculated with Enterococcus faecalis and BHI broth and incubated for 30 days. The broth in the tubes was analyzed for colony forming units to check for leakage of bacteria from the canal. The teeth from the groups were sectioned and analyzed using scanning electron microscopy (SEM). The Kruskal-Wallis test and analysis of variance were used to analyze the data with a significance level p < 0.05. Results: The BC-RRM and MTA groups showed similar sealing ability. The positive control showed leakage in all samples. The SEM imaging showed the presence of bacteria in all experimental groups at the material-tooth interface. Conclusions: No significant differences were noted in the experimental groups, providing sufficient evidence that any combination could be effectively used during endodontic microsurgery.

A STUDY OF IMPRESSION TECHNIQUE USING PUTTY MATERIAL OF PVS IMPRESSION MATERIAL (Putty 인상재를 채용한 PVS 인상채득 기법에 관한 연구)

  • Jeon, Young-Chan;Nah, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.535-543
    • /
    • 1997
  • In order to compare the accuracy of impression technique using the addition silicone putty and improved heavy body material, impression were taken for the natural 6 maxillary anterior teeth, and for the metal mast model that has full arch shape with 4 cylindrical abutment teeth. Marginal gingiva was retracted by routine method using retraction cord, and two techniques were tried to compare the length of impression materials in the gingival sulcus. This was aimed to see the effect of viscosity and hydraulic pressure of impression materials for the subgingival impression. Impressions for the full arch-shaped metal master model were taken to compare the linear stability of the different impression materials and their related techniques. The conclusions were as belows : 1. The one-step impression technique showed longer extension of impression material in gingival sulcus than two-step impression technique. 2. High viscosity and hydraulic pressure of impression material were useful to take subgingival impression. 3. There was no statistically significant difference for the two-dimensional accuracy of impression technique, but two-step technique showed better trend than one-step technique.

  • PDF

Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method (시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교)

  • Park, Joon-Man;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.109-118
    • /
    • 2010
  • Amended at the Law of indoor air quality management open a court according to the test method and excess standard of the fluid building material were changed. It used the paint and the putty in the fluid building material from this research and comparison of amended and original method it led and in about change direction of amended standard with change of the emission rate who is caused by in the amended test method and excess standard it examined. The reduction emission rate about 45% decreases in the change of test period of the paint, there was not an effect of the emission rate whom it follows in change of dry time. Also change of the emission rate whom it follows in change of application quantity the product which above $5\;mg/m^2h$ has the high emission rate the change of the emission rate is big but there was not change of the emission rate from the products of that others. The putty the emission rate about 61% decreases in case in the change of test period, there was not an effect of the emission rate whom it follows at dry time. The emission rate about 164% increased with increase of application quantity. It tried to compare two test methods, it compared in the paint and putty all current test method it was relaxed the possibility of knowing the thing there was a standard.

Study on the Property and Applicability of the Bisphenol-A Type Epoxy Putty According to the Mix of Filler (개발된 Bisphenol-A계 Epoxy Putty의 충전제 배합에 따른 물성 및 적용성에 관한 연구)

  • Wi, Koang-Chul;Oh, Seung-Jun
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.459-469
    • /
    • 2016
  • The goal of this study was to examine property changes induced by the choice of filler used with an epoxy resin that was developed in 2014 to restore cultural assets and consider the applicability of the resin as a restorative agent. The properties of putty mixed with 9 types of fillers and as-developed resins were compared with those of existing materials with regard to stability, superiority and applicability. The potential of the putty as an alternative material was also examined. The materials produced the best adhesiveness, color change and hardness results when mixed with lime. Micro balloon produced the best wear rates and hardening times, while diatomite produced the best tensile and compressive strengths. A plaster and white mineral pigment mixture produced the best specific gravity. Every material except for lime exhibited about 2.5-20 times higher wear rates than the existing material, which is thought to exhibit an excellent cutting force. The hardening time was enhanced by about 0.5-9 times to improve convenience. The stability of the relic was also ensured by improving hand staining without any shrinkage or deformation. The material exhibited about 0.5-27 times less yellowing. Thus, it is thought to be a material that can reduce property changes and reduce the degree of relic fatigue which occurs during reprocessing and sense of difference from relic.

THE MARGINAL ACCURACY OF TEMPORARY CROWN WITH DIFFERENT MATRIX (MATRIX에 따른 임시치관의 변연적합도에 관한 연구)

  • Ju, Tae-Hun;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.59-66
    • /
    • 1991
  • This study was designed to investigate the marginal accuracy of resin temporary crown with different matrix in indirect technique. Matrices were made from irreversible hydrocolloid impression material, putty type of vinyl polysiloxane silicone rubber and vacuum formed plastic sheet. The marginal discrepancies of the temporary crowns were measured using a measuring microscope. The obtained results were as follows 1. The marginal accuracy temporary crown using vinyl polysiloxane silicone rubber or vacuum formed plastic form was better than that of the temporary crown using irreversible hydrocolloid impression material. 2. The marginal accuracies of the temporary crown using the irreversible hydrocolloid impression material and putty type of the vinyl polysiloxane silicone rubber obtained the best results at the distal measuring point. 3. The vacuum formed plastic form was recorded a more acceptable marginal accuracy at the distal and mesial measuring points.

  • PDF