• Title/Summary/Keyword: Push-Pull Ventilation

Search Result 10, Processing Time 0.024 seconds

A Numerical Analysis on Improvement of Push-Pull Local Ventilation System (Push-Pull 국소환기시스템 개선에 관한 수치해석)

  • Yi, Chung-Seub;Jang, Sung-Cheol;Yoon, Kang-Ro
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.594-599
    • /
    • 2007
  • This study represents numerical analysis on the fluid flow and concentration characteristics by scattering fume at push-pull ventilation system. And the principal point is making optimum on improve an existing ventilation system. This phenomenon simulated about local ventilation system by using commercial CFD tool and base on these fact has find improvements. Advanced model shows most low different pressure and velocity which are suction capability at inlet surface of pull hood has most uniformity. When compared with existing model, Improved model has more good ventilation performance.

  • PDF

Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Cross Draft Directions and Velocities Using Smoke Visualization Technique (기류 가시화기법을 이용한 방해기류 방향과 속도에 따른 푸쉬풀 후드 효율 평가)

  • Song, Se-Wook;Kim, Tae-Hyeung;Ha, Hyun-Chul;Kang, Ho-Gyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.36-44
    • /
    • 2005
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank in recent years. Efficiency of push pull hood system is affected by various parameters, such as cross draft, vessel shapes, size of tanks surface, liquid temperature, and so on. Among these, velocity of cross draft might be one of the most influencing factor for determining the ventilation efficiency. To take account of the effect of cross draft velocities over 0.38m/s, a flow adjustment of ${\pm}$20% should be considered into the push and +20% into the pull flow system Although there are many studies about the efficiency evaluation of push pull hood system based on CFDs(Computational Fluid Dynamics) and experiments, there have been no reports regarding the influence of velocities and direction of cross-draft on push-pull hood efficiency. This study was conducted to investigate the influence of cross draft direction and velocities on the capture efficiency of the push-pull ventilation system. Smoke visualization method was used along with mock-up of push-pull hood systems to verify the ventilation efficiency by experiments. When the cross-draft blew from the same origins of the push flows, the efficiency of the system was in it's high value, but it was decreased significantly when the cross-draft came from the opposite side of push flows Moreover, the efficiency of the system dramatically decreased when the cross-draft of open surface tank was faster than 0.4m/s.

Numerical Analysis on the Improvement of Fume Mixing Ratio in the Push-Pull Local Ventilation System (급기-흡기 국소환기시스템의 성능개선에 관한 수치해석)

  • Yi, Chung-Seob;Suh, Jeong-Se;Yoon, Ji-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.867-872
    • /
    • 2010
  • Numerical analysis has been conducted to investigate the fluid flow and fume mixing ratio characteristics of scattering fume in a push-pull ventilation system and optimally improve the flow patterns of scattering fume in the existing ventilation system. This ventilation system has been simulated by using commercial CFD code. In the case of the existing system, although the air is sprayed from air-curtain to prevent the fume from being scattered in upper hood, the improved air supply hood can remove the fume from the wide area in the high pressure. It is verified that the deeper plating storage is more advantageous. Also, by installing the shied around the plating storage, the scattering of the fume to the atmosphere was prevented effectively by surrounding flux.

A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration (중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구)

  • Cheong, Hoe Kyeong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

Applicability of Computational Fluid Dynamics on Industrial Ventilation Engineering (산업환기공학에 대한 전산유체역학의 응용가능성)

  • Ha, Hyun-Chul;Kim, Tae-Hyeung;Shim, Kwang-Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.163-177
    • /
    • 1998
  • Computational Fluid Dynamics(CFD) was applied to predict air flow around the hoods : circular hoods, square hoods, and push-pull hoods. A commercially available CFD software, CFD-ACE(Ver. 4.0), was tested, which is based on the finite volume method using the ${\kappa}-{\varepsilon}$ turbulence model. Numerical results were compared with the experimental, analytical and numerical results from other studies. CFD solutions showed an excellent agreement with the previous experimental and numerical results. It is promising that CFD techniques could be applied on the variety of complex problems in the industrial ventilation engineering.

  • PDF

Numerical Study for Influence of Crossdraft Directions and Magnitudes on Push-Pull Ventilation Systems (푸시풀 후드시스템의 방해기류 방향 및 세기의 영향에 관한 수치적 연구)

  • Li, Xiao Yu;Kim, Tae Hyeung;Piao, Cheng Xu;Ha, Hyun Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.161-170
    • /
    • 2008
  • 푸쉬-풀 환기시스템은 도금조와 같이 흡인해야 할 거리가 상대적으로 긴 경우에 많이 사용되고 있다. 그러나, 창문이나 출입문을 통한 방해기류가 푸쉬-풀 환기시스템의 오염물질 제어효율을 심각하게 훼손시키고 있다고 추측하고 있으나 이에 대한 세부적인 연구가 부족한 상태에 있다. 따라서, 본 연구에서는 전산유체역학(Computational fluid dynamics)을 이용하여 푸쉬-풀 환기시스템에서의 방해기류의 방향과 세기가 흡인효율에 어떠한 영향을 미치는지에 대해 평가해 보았다. 선형흡인효율(Linear capture efficiency) 방법을 이용하여 푸쉬-풀 환기시스템에서 가상의 개방조에서 발생한 오염물질이 푸쉬-풀 시스템에 의하여 포집되지 못하고 누출되는 구역이 어딘지를 찾아낼 수 있었다. 전산유체역학 컴퓨터시뮬레이션은 AIRPAK2.1 (FLUENT CODE) 소프트웨어를 사용하였다. 푸쉬-풀 후드시스템에 방해기류가 강하게 작용하면 상대적으로 강한 와류가 발생하는데, 일반적인 난류모델인 ${\kappa}-{\varepsilon}$모델은 와류현상을 충분히 보여주지 못한 반면에 RNG 모델을 사용했을 때 실험결과를 적절히 모사해낼 수 있었다. RNG 모델을 이용하여 세가지 방향, 즉 푸쉬에서 풀 방향으로, 풀에서 푸쉬 방향으로 그리고 그에 수직되는 방향으로 방해기류가 있을 때의 푸쉬-풀 환기시스템의 흡인효율을 분석하였다. 방해기류가 0.25m/s이하일 때에는 흡인효율이 거의 떨어지지 않았으나, 방해기류가 0.6m/s에서 흡인효율이 40-70%로 떨어짐을 알 수 있었다. 따라서, 방해기류를 감소시킬 수 있는 방안에 대해서도 연구를 해야 되겠지만, 방해기류 존재 하에서 충분한 흡인 효율을 유지할 수 있는 푸쉬-풀 후드 설계기준에 대한 연구도 필요할 것으로 판단된다.

A Study of Local Ventilation Design on PC Programm (국소환기 설계의 전산화에 관한 연구)

  • Yoon, Myong Cho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.213-226
    • /
    • 1993
  • The purpose of this study is to computerize the design of single source for a duct work system which is essential for the improvement of working places. There are different types of hood, such as general hood, push pull hood and canopy hood. And out of these three types, general hood and canopy hood were used as subjects of this study. The software used here was Quattro Pro 123 programm, and the hardware was IBM PS/SX(type 5510-SK4 S/N 83-05164). And the results are tabulated in

    and
    . All of the hazardous factors of working places, except for physical factors, such as noise, vibration, illumination and etc, are control measurement related. In order words, workiong places that have problems with toxic gas, mist, fume, dust, odors, biological factors or wetness can be improved by means of the local ventilation design. However, the reqires very complicate processes, and in the case of canopy hood, particularly, one runs into difficulties due to frequent discrepancies generated from calculations through many processes. Recently, progress of the computer hardware technics has been dazzling, and also the software is development rapidly. As proven in the results of this study, it is good that designs for industrial ventilation systems are readily available for easy use. It is hopeful that young scholars will develop easier and quicker methods for local ventilation designs in the future.

  • PDF
  • Numerical Analysis on the Ventilation System Improvement in Air Shot Blast Room (Air Shot Blast 작업실 내부 환기 시스템 개선에 관한 수치해석)

    • Chin, Do-Hun
      • Journal of the Korean Society of Industry Convergence
      • /
      • v.25 no.5
      • /
      • pp.861-868
      • /
      • 2022
    • The purpose of this study is to design an effective atmospheric environment system through the design of the dust collection in the air shot room being operated in a domestic shipyard. The ventilation system in the current air shot room mostly uses a dust collecting filter to filter internal particles and releases them in the atmosphere. A conventional design was made too much. In order to prevent an error and draw an optimal design, Computational fluid dynamics (CFD) tried to be applied only to air shot room. In the advanced design technique, computer simulation was conducted to secure basic design data. In order to find the basic design of the ventilation system and the flow field in the air shot room at propeller mold workplace of a shipyard, the CFD was conducted. In the case of Model-1 as a conventional workplace, where air flows in the inlet due to the subatmospheric pressure generated by inhalation of an air blower and flows out to the outlet, a discharge flow rate was somewhat low, and there was the holdup zone in the room. In the case of Model-2 as an improved model, the ventilation system was improved in the Push-Pull type, and the holdup of the internal flow field was improved.

    Performance of Local Exhaust Ventilation Systems of Degreasing and Plating Workplaces (일부 탈지세척 및 도금공정 국소배기장치의 성능점검과 개선방안)

    • Han, Don-Hee
      • Journal of Korean Society of Occupational and Environmental Hygiene
      • /
      • v.8 no.2
      • /
      • pp.178-185
      • /
      • 1998
    • In order to evaluate and improve the performance of local exhaust ventilation systems for two TCE degreasing (A, B) and two electroplating (C, E) and one acid dipping & plating (D) operations located in Kimhae, the performance test was conducted with trace gases and a thermal anemometer (Kanomax 24-6111, Japan). For the inadequately designed systems, the improvement and redesigns in compliance with recommendation by ACGIH was suggested. The results of performance test for each system are as follows; 1. System of Workplace A was generally well-designed. Actual exhaust air flow rate was in excess of 68% above the recommended standard exhaust air flow rate. 2. System of Workplace B was very well-designed and completely enclosed. 3. All systems of Workplace C including hoods were poorly-designed and actual exhaust air flow rates were insufficient for open tanks. All systems should be upgraded according to ACGIH recommendations. 4. Supply and exhaust air flow rate of push-pull exhaust systems in Workplace D should be greatly increased. The width of flange of dipping tank hood should be increased with the value suggested. 5. System of Workplace E was well-designed. Actual exhaust air flow rate was in excess of 54% above the required.

    • PDF