Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer (원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과)

  • Kim, Woo-Chul;Kim, Hun-Jung;Park, Jeong-Hoon;Huh, Hyun-Do;Choi, Sang-Huoun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.28-35
    • /
    • 2011
  • Purpose: Recently, the use of radiosurgery as a local therapy in patients with early stage non-small cell lung cancer has become favored over surgical resection. To evaluate the efficacy of radiosurgery, we analyzed the results of stereotactic body radiosurgery in patients with primary or recurrent non-small cell lung cancer. Materials and Methods: We reviewed medical records retrospectively of total 24 patients (28 lesions) with non-small cell lung cancer (NSCLC) who received stereotactic body radiosurgery (SBRT) at Inha University Hospital. Among the 24 patients, 19 had primary NSCLC and five exhibited recurrent disease, with three at previously treated areas. Four patients with primary NSCLC received SBRT after conventional radiation therapy as a boost treatment. The initial stages were IA in 7, IB in 3, IIA in 2, IIB in 2, IIIA in 3, IIIB in 1, and IV in 6. The T stages at SBRT were T1 lesion in 13, T2 lesion in 12, and T3 lesion in 3. 6MV X-ray treatment was used for SBRT, and the prescribed dose was 15~60 Gy (median: 50 Gy) for PTV1 in 3~5 fractions. Median follow up time was 469 days. Results: The median GTV was 22.9 mL (range, 0.7 to 108.7 mL) and median PTV1 was 65.4 mL (range, 5.3 to 184.8 mL). The response rate at 3 months was complete response (CR) in 14 lesions, partial response (PR) in 11 lesions, and stable disease (SD) in 3 lesions, whereas the response rate at the time of the last follow up was CR in 13 lesions, PR in 9 lesions, SD in 2 lesions, and progressive disease (PD) in 4 lesions. Of the 10 patients in stage 1, one patient died due to pneumonia, and local failure was identified in one patient. Of the 10 patients in stages III-IV, three patients died, local and loco-regional failure was identified in one patient, and regional failure in 2 patients. Total local control rate was 85.8% (4/28). Local recurrence was recorded in three out of the eight lesions that received below biologically equivalent dose 100 $Gy_{10}$. Among 20 lesions that received above 100 $Gy_{10}$, only one lesion failed locally. There was a higher recurrence rate in patients with centrally located tumors and T2 or above staged tumors. Conclusion: SBRT using a CyberKnife was proven to be an effective treatment modality for early stage patients with NSCLC based on high local control rate without severe complications. SBRT above total 100 $Gy_{10}$ for peripheral T1 stage patients with NSCLC is recommended.

Analysis of Surveys to Determine the Real Prices of Ingredients used in School Foodservice (학교급식 식재료별 시장가격 조사 실태 분석)

  • Lee, Seo-Hyun;Lee, Min A;Ryoo, Jae-Yoon;Kim, Sanghyo;Kim, Soo-Youn;Lee, Hojin
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.3
    • /
    • pp.188-199
    • /
    • 2021
  • Objectives: The purpose was to identify the ingredients that are usually surveyed for assessing real prices and to present the demand for such surveys by nutrition teachers and dietitians for ingredients used by school foodservice. Methods: A survey was conducted online from December 2019 to January 2020. The survey questionnaire was distributed to 1,158 nutrition teachers and dietitians from elementary, middle, and high schools nationwide, and 439 (37.9% return rate) of the 1,158 were collected and used for data analysis. Results: The ingredients which were investigated for price realities directly by schools were industrial products in 228 schools (51.8%), fruits in 169 schools (38.4%), and specialty crops in 166 schools (37.7%). Moreover, nutrition teachers and dietitians in elementary, middle, and high schools searched in different ways for the real prices of ingredients. In elementary schools, there was a high demand for price information about grains, vegetables or root and tuber crops, special crops, fruits, eggs, fishes, and organic and locally grown ingredients by the School Foodservice Support Centers. Real price information about meats, industrial products, and pickled processed products were sought from the external specialized institutions. In addition, nutrition teachers and dietitians in middle and high schools wanted to obtain prices of all of the ingredients from the Offices of Education or the District Office of Education. Conclusions: Schools want to efficiently use the time or money spent on research for the real prices of ingredients through reputable organizations or to co-work with other nutrition teachers and dietitians. The results of this study will be useful in understanding the current status of the surveys carried out to determine the real price information for ingredients used by the school foodservice.

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Individual Thinking Style leads its Emotional Perception: Development of Web-style Design Evaluation Model and Recommendation Algorithm Depending on Consumer Regulatory Focus (사고가 시각을 바꾼다: 조절 초점에 따른 소비자 감성 기반 웹 스타일 평가 모형 및 추천 알고리즘 개발)

  • Kim, Keon-Woo;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.4
    • /
    • pp.171-196
    • /
    • 2018
  • With the development of the web, two-way communication and evaluation became possible and marketing paradigms shifted. In order to meet the needs of consumers, web design trends are continuously responding to consumer feedback. As the web becomes more and more important, both academics and businesses are studying consumer emotions and satisfaction on the web. However, some consumer characteristics are not well considered. Demographic characteristics such as age and sex have been studied extensively, but few studies consider psychological characteristics such as regulatory focus (i.e., emotional regulation). In this study, we analyze the effect of web style on consumer emotion. Many studies analyze the relationship between the web and regulatory focus, but most concentrate on the purpose of web use, particularly motivation and information search, rather than on web style and design. The web communicates with users through visual elements. Because the human brain is influenced by all five senses, both design factors and emotional responses are important in the web environment. Therefore, in this study, we examine the relationship between consumer emotion and satisfaction and web style and design. Previous studies have considered the effects of web layout, structure, and color on emotions. In this study, however, we excluded these web components, in contrast to earlier studies, and analyzed the relationship between consumer satisfaction and emotional indexes of web-style only. To perform this analysis, we collected consumer surveys presenting 40 web style themes to 204 consumers. Each consumer evaluated four themes. The emotional adjectives evaluated by consumers were composed of 18 contrast pairs, and the upper emotional indexes were extracted through factor analysis. The emotional indexes were 'softness,' 'modernity,' 'clearness,' and 'jam.' Hypotheses were established based on the assumption that emotional indexes have different effects on consumer satisfaction. After the analysis, hypotheses 1, 2, and 3 were accepted and hypothesis 4 was rejected. While hypothesis 4 was rejected, its effect on consumer satisfaction was negative, not positive. This means that emotional indexes such as 'softness,' 'modernity,' and 'clearness' have a positive effect on consumer satisfaction. In other words, consumers prefer emotions that are soft, emotional, natural, rounded, dynamic, modern, elaborate, unique, bright, pure, and clear. 'Jam' has a negative effect on consumer satisfaction. It means, consumer prefer the emotion which is empty, plain, and simple. Regulatory focus shows differences in motivation and propensity in various domains. It is important to consider organizational behavior and decision making according to the regulatory focus tendency, and it affects not only political, cultural, ethical judgments and behavior but also broad psychological problems. Regulatory focus also differs from emotional response. Promotion focus responds more strongly to positive emotional responses. On the other hand, prevention focus has a strong response to negative emotions. Web style is a type of service, and consumer satisfaction is affected not only by cognitive evaluation but also by emotion. This emotional response depends on whether the consumer will benefit or harm himself. Therefore, it is necessary to confirm the difference of the consumer's emotional response according to the regulatory focus which is one of the characteristics and viewpoint of the consumers about the web style. After MMR analysis result, hypothesis 5.3 was accepted, and hypothesis 5.4 was rejected. But hypothesis 5.4 supported in the opposite direction to the hypothesis. After validation, we confirmed the mechanism of emotional response according to the tendency of regulatory focus. Using the results, we developed the structure of web-style recommendation system and recommend methods through regulatory focus. We classified the regulatory focus group in to three categories that promotion, grey, prevention. Then, we suggest web-style recommend method along the group. If we further develop this study, we expect that the existing regulatory focus theory can be extended not only to the motivational part but also to the emotional behavioral response according to the regulatory focus tendency. Moreover, we believe that it is possible to recommend web-style according to regulatory focus and emotional desire which consumers most prefer.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

The Eating Behaviors, Nutrient Intakes and Hematological Status of Primary School Children in Gwangju (광주지역 일부 초등학교 아동의 식습관과 영양소 섭취량 및 혈액성상에 관한 연구)

  • 황금희;정난희;지혜련
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2001
  • The purpose of this study was to examine height, weight, chest circumference, sitting height, hemato logical status, eating behaviors and nutrient intakes for primary school children in Gwangju. The subjects consisted of 101 boys and 109 girls aged $10{\sim}12$ years old. There were significant differences in the height, weight, chest circumference, sitting height between the boys and girls. Hct, WBC, RBC, Hb, serum GOT, GPT and cholesterol were measured. With regard to meal regularity, 47.4% of the subjects has been 'regular'. With regard to meal volume, 15.8% of the subjects has been 'heavy'. With regard to meal balance, 44.7% of the subjects has been 'no'. The study also found that 63.4% of the subjects skipped breakfast, liked western food. Their dietary intakes were assesed for 1 day by means of 24 hours dietary recall method. The mean energy intakes of the subjects were 1,663kcal for boys and 1,427kcal for girls. The subjects for boys(girls) consumed 58(52)g protein, 43(60)g lipid, 4.8(6.5)g fiber, 470(514)mg calcium, 896(824)mg phosphorous, 9.6(16.4)mg iron, 3,301(3,468)mg sodium, 2,169(2,192)mg potassium, 388(466)RE retinol, 1.1(0.9)mg thiamin, 1.1(2.2)mg riboflavin, 12.2(26.3)NE niacin, 146(99)mg ascorbic acid and 251(159)mg cholesterol respectively. Energy, protein, calcium, iron and retinol intakes were lower than the Korean RDA. The intakes of fat, fiber, calcium, iron, sodium, retinol, riboflavin and niacin of the boys were significantly lower than those of the girls. There were positive correlations between meal time and protein intake or fat intake of fiber intake or iron intake or retinol intake : negative correlations between meal time and sodium intake : negative correlations between saltiness and cholesterol intake : positive correlations between use of perilla seeds and riboflavin intake or niacin intake : negative correlations between energy intake or carbohydrate intake or phosphorous intake : negative correlations between frequency of eating-out and protein intake or fat intake or fiber intake or iron intake or retinol intake or thiamin intake or riboflavin intake or niacin intake.

  • PDF

Perception of University Students on Nutrition Information According to Food & Nutrition Labeling Systems in Family Restaurant (패밀리 레스토랑의 영양표시제도 시행에 따른 대학생들의 영양정보에 관한 인식 연구)

  • Yang, Jung-Hwa;Heo, Young-Ran
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.2068-2075
    • /
    • 2013
  • The purpose of this study is to investigate the perception of university students on nutritional information according to food and nutrition labeling systems. A total of 310 customers, who visited family restaurant, were surveyed by a self-recorded questionnaire from March 2006 to April 2011. A total of 286 respondents were surveyed; of the respondents, 108 were males and 178 were females. Two surveys were conducted on the perception of the respondent's health: once in 2006 and once in 2011. According to these surveys, 63.6% and 54% of respondents perceived themselves as unhealthy, respectively. When ordering a meal, respondents were more concerned with price rather than taste, nutrition, new menu items, and food presentation. Compared with 2006, in 2011 more respondents felt that family restaurants provided enough nutritional information and practical use of that information to their customers. When surveyed, respondents felt that the total calories played a significantly higher role in ordering food than foods with higher nutritional values. There was a significant increase in satisfaction with the current nutrition labeling system; in 2006, $2.87{\pm}0.99$, and 2011, $3.35{\pm}0.84$. There was also a significant increase in individuals who felt that there was a need for an ingredient labeling system; $3.68{\pm}0.9$ in 2006 and $4.32{\pm}0.61$ in 2011. There was also a higher demand for nutritional information; $2.85{\pm}0.66$ in 2006, $3.06{\pm}0.65$ in 2011. From these results, it was concluded that the nutrition labeling system adopted by family restaurants did not affect the degree of customers' interest in nutritional information. Contrast to the results, the amount and frequency of nutritional information provided to customers have increased continuously since 2006. Therefore, the nutrition labeling system and recommended dietary allowance should be expanded in order to promote a healthy diet.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF