• Title/Summary/Keyword: Purpose of use

Search Result 19,341, Processing Time 0.051 seconds

A Study on the Determinants of Land Price in a New Town (신도시 택지개발사업지역에서 토지가격 결정요인에 관한 연구)

  • Jeong, Tae Yun
    • Korea Real Estate Review
    • /
    • v.28 no.1
    • /
    • pp.79-90
    • /
    • 2018
  • The purpose of this study was to estimate the pricing factors of residential lands in new cities by estimating the pricing model of residential lands. For this purpose, hedonic equations for each quantile of the conditional distribution of land prices were estimated using quantile regression methods and the sale price date of Jangyu New Town in Gimhae. In this study, a quantile regression method that models the relation between a set of explanatory variables and each quantile of land price was adopted. As a result, the differences in the effects of the characteristics by price quantile were confirmed. The number of years that elapsed after the completion of land construction is the quadratic effect in the model because its impact may give rise to a non-linear price pattern. Age appears to decrease the price until certain years after the construction, and increases the price afterward. In the estimation of the quantile regression, land age appears to have a statistically significant impact on land price at the traditional level, and the turning point appears to be shorter for the low quantiles than for the higher quantiles. The positive effects of the use of land for commercial and residential purposes were found to be the biggest. Land demand is preferred if there are more than two roads on the ground. In this case, the amount of sunshine will improve. It appears that the shape of a square wave is preferred to a free-looking land. This is because the square land is favorable for development. The variables of the land used for commercial and residential purposes have a greater impact on low-priced residential lands. This is because such lands tend to be mostly used for rental housing and have different characteristics from residential houses. Residential land prices have different characteristics depending on the price level, and it is necessary to consider this in the evaluation of the collateral value and the drafting of real estate policy.

Prevalence and Risk Factors of Candida Sepsis in Neonatal Intensive Care Unit (신생아 중환자실에서 캔디다 패혈증의 발생 추이와 위험 인자)

  • Choi, Ic Sun;Lim, Suk Hwan;Cho, Chang Yee;Choi, Young Youn;Hwang, Tai Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.836-846
    • /
    • 2002
  • Purpose : With the development of neonatal intensive care and the increased use of systemic antibiotics, candida sepsis has become one of the most important causes of neonatal morbidity and mortality. The purpose of this study was to investigate the prevalence rate and its associated risk factors. Methods : We retrospectively reviewed medical records of 28 cases with candida sepsis who were admitted in the neonatal intensive care unit(NICU) of Chonnam University Hospital from July 1995 to June 2001. Twenty-nine patients without candida sepsis were enrolled for the control group to verify the risk factors. Results : The overall incidence of candida sepsis was 0.61% for all NICU admissions and 3.68% for all very low birth weight infants with the gradual increase of the annual prevalance rate over time. The endotracheal intubation, percutaneous central vein catheter(PCVC), umbilical vein catheter, total parenteral nutrition, intralipid and dopamine were more applied than the control group (P<0.01 for all). The durations of mechanical ventilator care, central catheter appliance, nothing per os, and admission were also significantly longer than the control group(P<0.01 for all). Ampicillin/ sulbactam, ceftazidime, amikacin, netilmicin, teicoplanin and imipenem/cilastatin were significantly more used than the control group(P<0.05). The durations of ampicillin/sulbactam, ceftazidime, netilmicin and imipenem/cilastatin administration were also proved to be significant as the risk factors(P<0.01). Conclusion : The average annual prevalence rate of candida sepsis in NICU for six years was 0.61% with gradual increasing tendency over time. The elimination of the above risk factors is important in decreasing neonatal morbidity and mortality associated with candida sepsis.

Teachers' Importance Perception of the Contents in Housing Unit of Middle School Technology and Home Economics Subject (중학교 기술 가정 교과의 주생활단원 내용에 대한 교사의 중요도 인식)

  • Jun, Kyung-Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.4
    • /
    • pp.223-237
    • /
    • 2008
  • The purpose of this research was to provide the information needed for improving the contents in housing unit of middle school technology and home economic textbook. For this purpose, a survey questionnaire was developed to examine teachers' importance perception of 48 contents in housing unit. A direct survey and an e-mail survey were used to collect data from teachers, and a total number of 233 data were analyzed. Conclusions were summarized as following: 1. Among the 48 contents in housing unit, the average score of teachers' importance perception of the 18 contents on 'interior environment and equipments' was 3.94; the average score of teachers' importance perception of the 15 contents on 'living space plan and use' was 3.78; and the average score of teachers'importance perception of the 15 content on 'housing maintenance and repair' was 3.42. Therefore, the 15 contents on 'housing maintenance and repair' must be revised. 2. Teachers' importance perception of 25 contents, among the 48 contents in housing unit, were significantly differentiated by gender, age, teaching experience, scholastic attainment, subject in charge(technology, home economics, technology and home economics), school type(boys' middle school, girls' middle school, coeducation), and region(city, county). Therefore, the 25 contents, of which importance perception were influenced by teachers' characteristics, must be revised in order to maintain the consistent importance perception. Suggestions were that the team teaching of technology and home economic textbook was more recommendable; that the local situations must be considered in the contents of housing unit and; that the contents of housing unit must be segmented into a minimum unit for the accurate evaluation.

  • PDF

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Differences in Patients' and Family Caregivers' Ratings of Cancer Pain (암환자와 그 가족간호자가 지각하는 환자의 통증강도 차이)

  • Kim, Hyun-Sook;Yu, Su-Jeong;Kwon, Shin-Young;Park, Yeon-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.1
    • /
    • pp.42-50
    • /
    • 2008
  • Purpose: Undertreatment of canter pain, especially due to the differences in the perception of pain between the patients and caregivers, is a well recognized problem. The purpose of this study were to determine if there exist differences in communication about pain intensity scores between patients and their family caregivers in Korea. Methods: A total of 127 patient-family caregiver dyads who have experienced canter pain participated in this study at a hospital in Seoul for six months. The data were obtained by fare to face interview with a structured questionnaire based on Brief Pain Inventory-Korean version and other previous researches. The clinical information for all patients was compiled by reviewing their medical records. Results: Patients' 'worst-pain for 24-hour' and 'right-now-pain' scores estimated by family caregivers were significantly higher than those by patient themselves. The degree of agreement between patients and family caregivers in the estimate of patients' 'worst-pain for 24-hour' intensity categories was 78.7% for 'severe pain', 40% for 'no pain', 27.5% for 'mild pain' and 22.9% for 'moderate pain'. In case of 'right-now-pain' intensity categories, the agreement was 50% for 'severe pain', 47.2% for mild pain, 46.3% for 'no pain', and 26.3% for 'moderate pain'. Conclusion: This study demonstrates that the degree of agreement between patients and family caregivers in the estimate of patients 'pain intensity categories was less than 50% except for 'severe pain'. The results indicate that Korean family caregivers tend to overestimate the canter pain intensity of their caring patients, especially, when a lancer patient has 'moderate' or 'mild pain'. Health Providers are advised to educate patient-family caregiver dyads to use a pain measurement scale to promote their agreement in pain Intensity stores. Further analyses and studies are needed to identify the factors and differences that influence their communication about pain intensity scores between patients and their family caregivers.

  • PDF

How does the introduction of smart technology change school science inquiry?: Perceptions of elementary school teachers (스마트 기기 도입이 과학탐구 활동을 어떻게 변화시킬 것인가? -교육대학원 초등과학 전공 교사의 인식 사례를 중심으로-)

  • Chang, Jina;Joung, Yong Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.2
    • /
    • pp.359-370
    • /
    • 2017
  • The purpose of this study is to explore the changes caused by using smart technology in school science inquiry. For this, we investigated 12 elementary school teachers' perceptions by using an open-ended questionnaire, group discussions, classroom discussions, and participant interviews. The results of this study indicate that the introduction of technology into classroom inquiry can open up the various possibilities and can cause additional burdens as well. First, teachers explained that smart technology can expand the opportunities to observe natural phenomena such as constellations and changing phases of the moon. However, some teachers insisted that, sometimes, learning how to use new devices disrupts students' concentration on the inquiry process itself. Second, teachers introduced the way of digital measurement using smart phone sensors in inquiry activities. They said that digital measurement is useful in terms of the reduction of errors and of the simplicity to measure. However, other teachers insisted that using new devices in classroom inquiry can entail additional variables and confuse the students' focus of inquiry. Communication about inquiry process can also be improved by using digital media. However, some teachers emphasized that they always talked about both the purpose of using SNS and online etiquettes with their students before using SNS. Based on these results, we discussed the necessity of additional analysis on the various ways of using digital devices depending on teachers' perceptions, the types of digital competency required in science inquiry using smart technology, and the features of norms shaped in inquiry activities using smart technology.

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Interobserver and Intraobserver Reproducibility of SUL Measurements in Reference Organs on FDG PET/CT (FDG PET/CT 검사 시 참고장기에서 측정한, 제지방체중으로 표준화한 표준화 섭취계수의 관찰자 사이 및 관찰자 내 재현성에 대한 연구)

  • Kim, Seong Su;Shin, Yong Cheol;Lee, Sun Do;Lee, Nam Ju;Kim, Jong Cheol;Lee, Chun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Purpose: The use of SUV which should be normalized by lean body mass (LBM) is recommended for PET response criteria in solid tumors. LBM which was determined by whole body CT was used for SUV normalization (SUL) in this study. The purpose of the present study was to assess interobserver and intraobserver reproducibility of SUL measurements in reference organs. Materials and Methods: F-18 FDG PET/CT was conducted on 52 subjects and LBMs were directly determine by whole body CT for normalization of SUV. The 3 cm diameter spherical VOI, $1\times2$ cm cylindrical VOI, 2 cm diameter spherical VOI were placed in the liver, descending aorta and spleen, respectively. Experienced two observers measured SULmax and SULmean in each organ. Repeated measurements were conducted two weeks apart by observer 1 blind to previous results. Similarly, measurements were conducted on the same patients by observer 2. For assessing reproducibility(or repeatability), the paired t-test, Pearson's correlation coefficients (CC), and technical error of measurement (TEM) were calculated. Results: For interobserver reproducibility in liver SULmax and SULmean, no significant differences were found between observers(paired t-test, P=0.536, 0.293, respectively). CC and TEM for liver SULmean were 0.909 (P=0.000) and 0.067 SUL unit, respectively. Corresponding figures for liver SULmax were 0.882 (P=0.000) and 0.117 SUL unit, respectively. For intraobserver reproducibility in liver SULmax and SULmean, no significant differences were observed within observer1 (paired t-test, P=0.374, 0.268, respectively). CC and TEM for liver SULmean were 0.924 (P=0.000) and 0.061 SUL, respectively. Corresponding figures for liver SULmax were 0.908 (P=0.000) and 0.104 SUL, respectively. Similarly, no significant differences were found in SULmax and SULmean of the spleen and aorta between observers. Conclusion: The current study demonstrated that both SULmean and SULmax measurements in normal reference organs are highly reproducible. Reproducibility of SULmean in reference organs were slightly better than SULmax. Interobsever technical error of measurement was less than 0.10 SUL unit for liver SULmean, and 0.12 SUL unit for liver SULmax. Intraobsever technical error of measurement was less than 0.07 SUL unit for liver SULmean, and 0.11 SUL unit for liver SULmax.

  • PDF

A Comparative Study on the Improvement of Curriculum in the Junior College for the Industrial Design Major (2년제 대학 산업디자인전공의 교육과정 개선방안에 관한 비교연구)

  • 강사임
    • Archives of design research
    • /
    • v.13 no.1
    • /
    • pp.209-218
    • /
    • 2000
  • The purpose of this study was to improve the curriculum for industrial design department in the junior colleges. In order to achieve the purpose, two methodologies were carried out. First is job analysis of the industrial designers who have worked in the small & medium manufacturing companies, second is survey for the opinions of professors in the junior colleges. Some results were as follows: 1. The period of junior college for industrial designers is 2 years according to present. But selectively 1 year of advanced course can be established. 2. The practice subjects same as computational formative techniques needed to product development have to be increased. In addition kinds of selection subjects same as foreign language, manufacturing process, new product information and consumer behavior investigation have to be extended. 3. The next subjects need to adjust the title, contents and hours. (1) The need of 3.D related subjects same as computer modeling, computer rendering, 3.D modeling was high. The use of computer is required to design presentation subjects. (2)The need of advertising and sale related subjects same as printing, merchandise, package, typography, photography was low, the need of presentation techniques of new product development was high. (3) The need of field practice, special lecture on practice and reading original texts related subjects was same as at present, but these are not attached importance to form. As the designers feel keenly the necessity of using foreign language, the need of language subject was high.

  • PDF

Analysis of Reading Materials Presented in Chemistry and Science Textbooks and Survey on Utilization Reading Materials (화학 및 과학 교과서에 기술된 읽기자료 분석 및 활용도 조사)

  • Lim, Mi-Kyung;Yoo, Mi-Hyun;Nam, Seok-Hyun
    • Journal of Science Education
    • /
    • v.36 no.1
    • /
    • pp.69-83
    • /
    • 2012
  • The purpose of this study was to analyze the reading materials in 7th curriculum and 2009 revised high school chemistry I textbook for identifying the problems of reading material presented in science textbooks and to investigate science teachers' recognition about utilization reading materials in science textbook. For this purpose, each four 7th curriculum and 2009 revised high school chemistry I textbook were analyzed according to the number of reading materials, the type of contents and the type of students' activities. In addition, the secondary school science teachers' recognition about utilization reading materials in science textbook was investigated. The results were as follows: First, anylizing reading materials in chemistry I textbooks showed that and the rate of reading materials were presented from 7.9 to 17.1% in 7th curriculum and from 20.6 to 28.2% in 2009 revised curriculum textbook. It implies that the rate of reading materials in 2009 revised textbooks increases more than those in 7th curriculum textbook. The result of analyzing the type of contents, 'life sciences' was the largest proportion with 34.3 % in the 7th curriculum chemistry I, but 'enrichment and supplement of knowledge' was the largest proportion with 23.7% in 2009 revised curriculum. Analyzing the type of student activities, only 13% of the reading materials in 7th National Curriculum textbook was found to be inquiry type, but 35% of the reading materials in the 2009 revised curriculum. appears to be inquiry type. It suggested that the curriculum objectives was reflected in the textbook. Second, investigating recognition of teachers' perceptions of utilization science textbooks, 67% teachers responded that they used the reading materials in their science class, but teachers who didn't use the reading materials was almost 33%. A large number of teachers responded that the reading materials associated with the real-life needed for integrated education and thought that the reading materials about 'life and science' should be included in the science textbooks.

  • PDF