• Title/Summary/Keyword: Purpose of use

Search Result 19,341, Processing Time 0.049 seconds

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Comparison Study of Anterior Cruciate Ligament Reconstruction Using Bone-Patella Tendon-Bone Autograft and Achilles Tendon Allograft (이식건에 따른 관절경하 전방 십자 인대 재건술의 비교 -자가 골-슬개건-골과 동종 아킬레스건의 비교-)

  • Seo, Joong-Bae;Jung, Hong-Geun;Kim, Myung-Ho;Park, Hee-Gon;Yoo, Moon-Jib;Byun, Woo-Sup;Lee, Joo-Hong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the clinical results of the arthroscopic anterior cruciate ligament reconstruction used by Bone-Patella tendon-Bone autograft and Achilles tendon allograft. Materials and Methods: We reviewed the results of patients who had been managed with arthroscopic anterior cruciate ligament reconstruction using different graft such as Bone-Patella tendon-Bone autograft and Achilles les tendon allograft. 60patients (average age, 33.5 years)were retrospectively evaluated. The one group(average age, 33.4 years) was 32 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Bone-Patella tendon-Bone autograft. The other group(average age, 32.1 years) was 28 patient who had been managed with arthroscopic anterior cruciate ligament reconstruction using Achilles tendon allograft. 2 groups were evaluated subjectively by Lysholm knee scoring scale and objectively by KT-2000 arthrometer. The follow-up period was more than a year(average, 18 month). An early rehabilitation protocol was instituted. Results: On Lysholm knee scoring scale, the final evaluation was nearly normal in all patients. We could not find statistical difference among the two groups by KT-2000TM arthrometer. Conclusion: The use of allografts may be an acceptable choice for ACL reconstruction.

  • PDF

A Study on the Botanical Garden Visitors' Eco-consciousness and Motivation (식물원 이용객의 생태의식과 이용동기에 관한 연구)

  • Jeong, Jae-Man
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.2
    • /
    • pp.235-246
    • /
    • 2014
  • The purpose of this study was to determine the correlation between botanical garden visitors' ecological consciousness and their needs, in order to provide some effective measures to manage them. For this purpose, 3 study points were set up: "botanical garden visitors' ecological consciousness and their needs", "differences of such consciousness depending on their demographic variables" and the "relationship between such consciousness and their needs". To this end, Botanical garden visitors were surveyed for an empirical analysis. The visitors' awareness about ecology was measured with Dunlap's 15-item NEP Inventory, while their needs were analyzed in reference to Maslow's 7-Step Human Desire Ladder. The survey was conducted at Botanical garden for 3 days. As a result, a total of 360 questionnaires were returned. The results of this study can be summarized as follows; First, the visitors' ecological consciousness and their needs were higher than normal level. In terms of their consciousness of ecology, their awareness of the ecological crisis potential and anti-humanism were the highest. In terms of their needs, the aesthetic need was the highest, followed by the cognitive need. On the other hand, the needs for self-achievement and self-esteem were the lowest; except them, the higher the needs were positioned at Maslow's ladder of desire, the more responsive the subjects became. As a result of analyzing the correlation between the subjects' consciousness of ecology and their needs, it was found that the correlation was negative in some sub-areas, while being positive in other sub-areas. After all, the ratio of the sub-areas having a positive correlation was 3 times higher than that of the sub-areas having a negative correlation. Even as for the correlation coefficient values, they were higher in the positive sub-areas, which suggests that the correlation between wetland visitors' ecological consciousness and their needs was positive, although at a lower level, in overall terms. As a result of comparatively analyzing visitors' needs by dividing them into 3 sub-groups depending on the levels of their ecological consciousness, it was found that the higher their consciousness of ecology was, the higher their needs were. Overall, botanical garden visitors' ecological awareness was higher than the normal level, and it was estimated that such awareness would continue to increase. Hence, it could be inferred that their needs, particularly their aesthetic and cognitive ones, would also continue to increase. Accordingly, it is important to manage the wetland landscape making use of its visual resources, while keep providing the visitors with the contents fulfilling their need for knowledge.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

A Study on Basic Plan for Upscaling Environmental Conservation Value Assessment Map(ECVAM) of National Land in South Korea (대축척 국토환경성평가지도 작성방안 연구)

  • Lee, Moung-Jin;Jeon, Seong-Woo;Lee, Chong-Soo;Kang, Byung-Jin;Song, Won-Kyong
    • Journal of Environmental Policy
    • /
    • v.6 no.3
    • /
    • pp.115-145
    • /
    • 2007
  • This study was performed for developing upscaling Environmental Conservation Value Assessment Map(ECVAM) of National Land in South Korea and presenting the application method of ECVAM. This ECVAM adopted the least indicator method and uses a Geographic Information System(GIS). This map is made through evaluation of 67 items. As a result, the construction of ECVAM was defined as a process of identifying land use to scientifically assess the physical and environmental value of land and classify conservation value into several grades for the sustainable management of environmental resources. After applying ECVAM criteria of five degrees to the whole of study area, Grade I, showing the highest conservation value, accounted for 29.3% by land area of ECVAM. Grades II, III, IV and V likewise accounted for, respectively, 21.7%, 17.2%, 7.1% and the lowest conservation value of 24.7%. other result, ECVAM and land suitability assessment agreement rate is Grade I 33.05%, Grades II, III, IV and V likewise accounted for 12.92%, 15.05%, 36.93% and last value of 53.28% This study set up "the realization of the improvement ECVAM" as the vision of the advancing strategy. In order to accomplish the vision, this study established the purpose as follow; constructing strategic assessment value relation to ECVAM based on knowledge, arranging the foundation to upscaling assessment value And this study devised preparatory plans to achieve the vision and the purpose as next; construction on base theme map by 1:5,000 scalie, base on land register theme map and precision land cover map. Therefore, for applying the result of this study to the upscaling Environmental Conservation Value Assessment Map(ECVAM), it considers regularly the systematic categorization of preceding item, consideration issue of national environmental geographic information using the ECVAM.

  • PDF

The Changes of Smart Device Usage Status in Early Childhood: Comparison of 2015-2016 and 2017 Studies (유아 스마트 기기 사용 현황의 변화: 2015-2016년과 2017년의 연구 결과 비교)

  • So, Hyejin;Lim, Sungmin;Cho, Sang Yeun;Koh, Min Suk;Moon, Jin-Hwa
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.251-262
    • /
    • 2018
  • Purpose: This study aimed to identify changes in smart device usage trends of young children using two studies conducted in 2015-2016 and 2017 respectively. Methods: We compared the data of the previous study of 130 children (Group A) and the new study of 162 children (Group B). The children and parents were recruited from kindergartens in Seoul and Guri/Namyangju cities. We used the "Parental questionnaire for smart device usage status." Results: There were some changes in the smart device usage in young children and parental perception. In the 2017 study, smart device usage time increased during weekends (P<0.05) and the usage with siblings decreased (P<0.05). In 2017, the smart device was mostly used when children had to be quiet without disturbing others (36.8%). No significant difference existed in the main purpose of use: watching video clips (79.3% vs 76.6%). Overall control of the usage was still largely exercised by mothers; however, when using applications, mothers still only helped the children on request (51.8% vs 49.7%). Regarding the effect of smart device on children, responses of "not knowing" decreased and "will be negative" and "will be positive" increased (P<0.05). Additionally, most mothers thought that "Although the smart device is currently unnecessary, it will be needed in future" in 2017 (46.3%). Conclusion: Limiting the smart device usage time during the weekends and increasing parental involvements are recommended. Guidelines for smart devices usage in young children are also necessary considering the changes in parental attitudes in recognizing the smart device usage as unavoidable.