• 제목/요약/키워드: Purification method

검색결과 852건 처리시간 0.028초

Porphyran의 신속한 정제 방법 및 화학적 특성 (A Simple Purification Method and Chemical Properties of Potphyran from Porphyra yezoensis)

  • 박진희;구재근
    • 한국수산과학회지
    • /
    • 제41권6호
    • /
    • pp.409-413
    • /
    • 2008
  • A simple method for the purification of porphyran from laver Porphyra yezoensis was developed to obtain information for the development of food materials with biological functionality. Crude porphyran (CP) was extracted from dried laver in boiling water for 3 h, and then fractionated using cetylpyridinium chloride into an acidic fraction (CP-F1) and a neutral fraction (CP-F2). CP-F1 was fractionated further by fractional ethanol precipitation. Fraction CP-F1-70, precipitated at an ethanol concentration of 61-70% was the major fraction containing 68.1% of the yield from the initial fraction CP-F1. The CP-F1-70 fraction displayed a single band on Sepharose CL-4B with a molecular mass of 550 kDa, indicating a homogeneous polysaccharide. The molar ratio of galactose, 3,6-anhydro-L-galactose, 6-0-methyl-D-galactose and ester sulfate of CP-F1-70 was 1:0.32:0.07:0.53. This method is very useful for rapid and large-scale preparation of purified porphyran because it is compatible with mass production.

레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구 (Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer)

  • 임윤규;양해정;김영일
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

디프테리아 toxin 정제와 무독화 toxoid 백신 생산 (Purification of Diphtheia Toxin and the Production of Detoxificated Toxoid Vaccine)

  • 조민;유연우
    • KSBB Journal
    • /
    • 제14권2호
    • /
    • pp.248-254
    • /
    • 1999
  • 본 연구에서는 디프테리아 toxin을 정제한 후 무독화하여 toxid를 생산하기 위하여 crude toxin을 2중 U.F를 통해 분자량 100.000이상의 단백질과 30.000이하의 배지 유래 단백질 및 색소를 제거한 결과 순도 1,300 Lf/mg PN의 toxin을 정제하였다. 이를 다시 DEAE-ion exehange chromatography를 통해 toxin을 정제한 후 무독화하여 순도 2,560 Lf/mg PN의 toxoid를 얻을 수 있었다. 이와 같이 생산된 디프테리아 toxoid는 동물 실험 결과 toxin으로 reversion이 발견되지 않았으며, 역가에 있어서도 crude toxin을 무독화한 후 정제한 toxoid와 비교하여 더 우수하였고 대한민국 생물학적 제제 기준에 규정된 성인용 디프테리아 백신 순도 기준 2,500 Lf/mg PN 이상에 적합하였다. 따라서 본 연구를 통해 성인용 디프테리아 백신의 생산 가능성을 확인하였다.

  • PDF

조밀화 핵연료 집합체 저장에 의한 울진 1&2호기의 사용후 핵연료 저장조 정화능력 해석 (Analysis of Water Purification Capability of the Spent Fuel Storage Pool Using Consolidated Fuel Storage in Uljin 1&2)

  • Lim, Chae-Joon;Park, Goon-Cherl;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.83-94
    • /
    • 1990
  • 울진 1&2호기의 사용후 핵연료 중간저장을 위한 기존 저장조용량확장 방안으로서 maximum density rack (MDR)에 consolidated fuel을 저 장하여 현 9/3 노심에서 32/3으로 확장할 경우 방사능 농도가 적정기준 이하로 유지될 수 있는지 여부를 분석하였다. 이를 위해 본 연구에서는 정화계통의 연속적 운전방식과 주기적 운전방식에 대한 저장용수중의 방사능 농도계산을 위한 두 가지 계산 모델을 만들어 상호비교 하였다. 이 결과 두 경우 모두 32/3 노심저장에 대하여 기존 정화계통으로는 기준치인 5$\times$1-$^{-4}$ $\mu$Ci/ml이하로 유지시킬 수 없었다. 따라서 기존의 시설변경이 불가피하며 그 방안으로 사용후 핵연료 저장조에서의 양이온 탈염기 수를 증가시키는 방법이 타당한 것으로 나타났다.

  • PDF

저온 분사 공정으로 제조된 티타늄 코팅층의 치밀화에 미치는 열처리 분위기의 영향 (Effect of Heat Treatment Environment on the Densification of Cold Sprayed Ti Coating Layer)

  • 유지상;김형준;오익현;이기안
    • 한국분말재료학회지
    • /
    • 제19권2호
    • /
    • pp.110-116
    • /
    • 2012
  • This study investigated the effects of annealing environment for the densification and purification properties of pure titanium coating layer manufactured by cold spraying. The annealing was conducted at $600^{\circ}C$/1 h and three kinds of environments of vacuum, Ar gas, and $5%H_2+Ar$ mixture gas were controlled. Cold sprayed Ti coating layer (as sprayed) represented 6.7% of porosity and 228 HV of hardness, showing elongated particle shapes (severe plastic deformation) perpendicular to injection direction. Regardless of gas environments, all thermally heat treated coating layers consisted of pure ${\alpha}$-Ti and minimal oxide. Vacuum environment during heat treatment represented superior densification properties (3.8% porosity, 156.7 HV) to those of Ar gas (5.3%, 144.5 HV) and $5%H_2+Ar$ mixture gas (5.5%, 153.1 HV). From the results of phase analysis (XRD, EPMA, SEM, EDS), it was found that the vacuum environment during heat treatment could be effective for reducing oxide contents (purification) in the Ti coating layer. The characteristic of microstructural evolution with heat treatment was found to be different at three different gas environments. The controlling method for improving densification and purification in the cold sprayed Ti coating material was also discussed.

Preparation of High-Purity Urokinase Using Single-Step Hydrophobic Interaction Chromatography with p-Aminobenzamidine Ligand

  • Cao, Xue-Jun;Zhou, Jian-Hua;Huang, Zhen-Hui;Wu, Xing-Yan;Hur, Byung-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권2호
    • /
    • pp.196-203
    • /
    • 2002
  • A novel process for urokinase purification was studied using p-aminobenzamidine as the ligand and sepharose 4B as the matrix. The adsorption, washing, and elution conditions were optimized by an unusual method. An adsorption buffer containing 2.5 M NaCl and $1\%$ Tween 80 facilitated the adsorption of urokinase on the affinity media and prevented contaminants from binding to the p-aminobenzamidine affinity gel. It was found that $5\%$ Tween 80 removed most of the contaminants from the affinity column. A 0.2 M glycine elution buffer containing 0.5 M NaCl (pH 3.0) was found to have a strong elution ability with a high recovery and purity of urokinase. A crude urokinase material of231 IU/mg protein from human urine was purified to 124,300 IU/mg protein with a purification factor of 538 and yield of $86.7\%$. As a result, a high purity urokinase was obtained with only a single affinity chromatography step. The purification process was successfully scaled-up to a 2-1 chromatography column. The resulting urokinase eluate could be directly lyophilized, thereby complying with Chinese pharmacopoeia (1995 version) standards.

주목 식물세포(Taxus chinensis)배양으로부터 파클리탁셀 정제를 위한 흡착제 처리 공정 최적화 (Optimization of Adsorbent Treatment Process for the Purification of Paclitaxel from Plant Cell Cultures of Taxus chinensis)

  • 이충기;김진현
    • Korean Chemical Engineering Research
    • /
    • 제52권4호
    • /
    • pp.497-502
    • /
    • 2014
  • 바이오매스 유래 타르 및 왁스 성분은 파클리탁셀의 분리정제에 많은 악영향을 미치기 때문에 반드시 제거되어야 한다. 흡착제 처리는 식물세포배양으로부터 유래된 타르 및 왁스 성분을 매우 간단하고 효과적으로 제거할 수 있는 방법이다. 본 연구에서는 전처리 단계에서 상용흡착제 실로퓨트를 이용한 흡착제 처리 공정에서 주요 공정 변수들(온도, 시간, 용매, 건조시료/실로퓨트 비율)을 최적화하였다. 최적의 흡착제 처리 온도, 시간, 용매, 건조시료/실로퓨트 비율은 각각 $30^{\circ}C$, 15분, 메틸렌 클로라이드, 1:1(w/w)이었다. 이러한 결과는 TGA와 HPLC 분석을 통한 유기물의 흡착 양상으로도 확인하였다. 흡착제 처리 단계에서 순도 증가는 미미하였으나 타르 및 왁스 성분의 제거로 인한 후속공정의 공정 가능성과 편리성에 상당히 영향을 미쳤다.

섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제 (A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry)

  • 김호태;유황율;전경민;송두리;김진배
    • 공업화학
    • /
    • 제29권2호
    • /
    • pp.229-236
    • /
    • 2018
  • 섬유산업에서 배출되는 오일미스트를 함유한 배기가스를 처리하기 위해 개발되어 실제 현장에 적용되고 있는 electric fume collector (EFC) 설비의 집진판 오염에 의한 성능저하를 개선하기 위한 맞춤형 세정제를 검토하였다. 집진판 표면의 오염물질은 오일미스트가 장기간 축적되면서 심하게 탄화되어 일반 세정제로는 쉽게 제거하기 어려운 상태였다. 오염물질의 특성과 집진판 모재의 손상 등을 고려하여, 알칼리, 알코올, 글리콜 및 비이온계 계면활성제로 구성된 최적의 세정제 성분 조성을 결정하였다. 현장실증실험에는 개발된 세정제 원액을 9.1%로 희석한 용액을 이용하였으며, 단순한 분무방식으로 심하게 점착된 집진판 표면의 오염물질을 성공적으로 제거할 수 있었다. 집진판의 세척에 의하여 EFC 설비의 배기가스 정화성능 개선효과도 크게 향상되었다.

수소분리 및 정제를 위한 PSA(Pressure Swing Adsorption)시스템 안전성향상에 관한 연구 (A Study on the Safety Improvement of PSA System for Hydrogen Separation and Purification)

  • 오상규;이슬기;이준서;마병철
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.7-19
    • /
    • 2022
  • 일반적으로 수소의 정제는 화학적, 물리적인 방법을 통해 수행한다. 여러 종류의 정제방법 중 현재는 정제 용량 및 경제성이 가장 우수한 PSA(Pressure Swing Adsorption)를 이용한 정제방법이 가장 널리 사용되고 있다. 국내도 대부분 PSA를 이용하여 자동차 및 발전용 수소 연료전지 등에 사용하는 수소를 정제하고 있다. 기존 석유화학 단지중심의 부생수소는 운송 등의 어려움이 있다. 정부는 도시가스 공급망과 연계하여 소비지에서 직접 수소를 생산하는 수소추출기 설치 계획하고 있으며, 기업들도 이와 관련된 연구 및 실증 설비를 속속 설치하고 있는 실정이다. 유럽 등은 최근 PSA와 관련된 안전기준을 마련하여 시공 및 운영단계에서 체계적인 안전관리를 위한 노력을 기울이고 있으나, 국내는 PSA와 관련된 안전기준 마련이 아직까지는 미흡하다. 본 연구에서는 기존 PSA를 운영하고 있는 회사의 설문 및 위험성평가를 통해 기존설비의 문제점을 파악하고, 국외 기술기준에 이를 포함한 국내 기술기준을 작성하여 신규설치 및 기존 운영되고 있는 PSA시스템의 안전을 도모하고자 한다.

바이오의약품의 단백질 분리 및 정제를 위한 Avantor® ACE® 와이드 포어 HPLC 컬럼 가이드 (Avantor® ACE® Wide Pore HPLC Columns for the Separation and Purification of Proteins in Biopharmaceuticals)

  • Matt James;Mark Fever;Tony Edge
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.3.1-3.7
    • /
    • 2024
  • The article discusses the critical role of chromatography in the analysis and purification of proteins in biopharmaceuticals, emphasizing the importance of comprehensive characterization for ensuring their safety and efficacy. It highlights the use of Avantor® ACE® HPLC columns for the separation and purification of proteins, focusing on the analysis of intact proteins using reversed-phase liquid chromatography (RPLC) with fully porous particles. This article also details the application of different mobile phase additives, such as TFA and formic acid, and emphasizes the advantages of using type B ultra-pure silica-based columns for efficiency and peak shape in biomolecule analysis. Additionally, it addresses the challenges of analyzing intact proteins due to slow molecular diffusion and introduces the concept of solid-core (or superficially porous) particles, emphasizing their benefits over traditional porous particles for the analysis of therapeutic proteins. Furthermore, it discusses the development of Avantor® ACE® UltraCore BIO columns, specifically designed for the high-efficiency separation of large biomolecules, such as proteins, and demonstrates their effectiveness in achieving high-resolution separations, even for higher molecular weight proteins like monoclonal antibodies (mAbs). In addition, it underscores the complexity of analyzing and characterizing intact protein biopharmaceuticals, requiring a range of analytical techniques and the use of wide-pore stationary phases, operated at elevated temperatures and with relatively shallow gradients. It highlights the comprehensive range of options offered by Avantor® ACE® wide pore columns, including both fully porous and solid-core particles, bonded with a variety of complementary stationary phase chemistries to optimize selectivity during method development. The use of ultrapure and highly inert base silica is emphasized for enabling the use of lower concentrations of mobile phase modifiers without compromising analyte peak shape, particularly beneficial for LC-MS applications. Then the article concludes by emphasizing the significance of reversed-phase liquid chromatography and its compatibility with mass spectrometry as a valuable tool for the separation and analysis of intact proteins and their closely related variants in biopharmaceuticals.

  • PDF