• Title/Summary/Keyword: Pure-tone Audiometry

Search Result 60, Processing Time 0.027 seconds

Changes of the Blood Pressure and the Pulse Rate of the Rat after the Noise Exposure (소음이 백서 혈압 및 맥박수에 미치는 영향)

  • Roh, Jae-Hoon;Shin, Dong-Chun;Cha, Bong-Suk;Moon, Young-Hahn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.239-243
    • /
    • 1984
  • The vascular reaction such as the indirect blood pressure and the pulse rate of the tail to the noise were examined in 8 naive Sprague-Dawley rats of both sexes. The sounds used in the experiment were 1KHz and 4 KHz, 95dB pure tone generated by Nagashima Audiometry. The indirect blood pressure and the pulse rate were checked at the rat tail by Polygraph at 5 minutes interval. The results were as follows: 1. The blood pressure and the pulse rate increased maximally 5 minutes after the exposure to both sounds. 2. The blood pressure and the pulse rate returned normal range within 20 minutes after the exposure of both sounds. 3. The increment of the blood pressure and the pulse rate was greater after the sound of 4KHz than after that of 1KHz, but it wasn't statistically significant.

  • PDF

Erogonomic assessment of "Noraebang" noise and potential hearing-loss and hearing protection strategies (노래방 소음 및 난청가능성의 인간공학적 평가와 청각보호방안)

  • 박민용
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.79-90
    • /
    • 1996
  • A research project was conducted to assess the levels of noise exposed to "Noraebang" users and potential hazards to noise-induced hearing loss due to commercial Noraebang noise. A two-way, mixed-factors factorial design was employed for the experiment using independent variables of "noise source" (no- singer, 1-singer, and 2-singer conditions) and "music type" (Trot, Ballad, and Rock music) with 18 normal hearing subjects. Each singer group sang 5 popular songs of each music type in each signing condition, whereas background music was just played for the no-singer condition. For each music played/sung, equivalent continuous sound pressure levels and maximum sound pressure levels were measured for data analysis purposes. Pure-tone audiometry was applied for measuring subjects' hearing threshold levels before and after exposure to Noraebgang noise. The statistical analyses indicate that average continuous noise levels due to Noraebang leisure environment were very serious, especially when two people were singing (higher than 95 dBA). Furthermore, maximum noise levels often exceeded the OSHA's non-premissible 115 dBA level. Worse yet, hearing loss assessment implies that Noraebang facilities may pose a serious threat to noise-induced hearing loss, based on 6-8 dB loss at 125 Hz and 8 dB loss at 4000 Hz after about 1-hour Noraebang noise exposure.

  • PDF

A Case of Korean Medical Treatment of Relapsing sudden hearing loss occurred three months later (발병 3개월이 지난 재발성 돌발성 난청 치험 1례)

  • An, Jae-Hyun;Jung, Hyun-A
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.2
    • /
    • pp.98-105
    • /
    • 2016
  • Objectives : The purpose of this study is to report the Korean medical treatment on sudden sensorineural hearing loss(SSNHL). Methods : The patient who has been diagnosed SSNHL had symptoms with hearing loss, tinnitus, and aural fullness. The patient was received outpatient to Dunsan oriental hospital for 3 months and was treated with oriental medicine(acupuncture, herbal-medicine, converting of Hominis placenta, warm needling and vapor treatment). Two approaches were used in order to evaluate the effect of the treatment. The hearing recovery was measured with pure tone audiometry, and the decrease of tinnitus and aural fullness was identified by patient's subjective expression. Results : The patient has his hearing restored fully and the symptoms of SSNHL accompanied with adjunctive symptoms including tinnitus and aural fullness were improved.Conclusions : This study shows that the Korean medical treatment effects on the SSNHL.

Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Presbycusis: A Case Report (한방 복합 치료 및 소리 재활 치료로 호전된 노인성 난청 치험 1례)

  • Jea, Ha-Kyung;Min, Ye-Eun;Oh, Yeon-Ju;Kang, Jun-Hyeok
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.34 no.3
    • /
    • pp.102-111
    • /
    • 2021
  • Objectives : The purpose of this study is to report the case of a presbycusis patient whose hearing had improved. Methods : A 81-year-old male diagnosed with presbycusis were treated with Korean medical interventions (acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and Threshold sound conditioning(TSC) for 3 months. Pure tone audiometry(PTA) was performed for the evaluation. Results : The patient's hearing was improved from moderate to mild level according to the Classification of Hearing Loss(International Organization for Standardization, 1969). The average hearing were improved from 40.5 dB to 32.7dB on the left side, 46.9dB to 34.1dB on the right side. Conclusions : We observed an improvement in a presbycusis patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss as well as prebyscusis.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Bilateral Sudden Sensorineural Hearing Loss : A Case Report (한방 복합 치료 및 소리재활치료로 호전된 양측성 돌발성 난청 치험 1례)

  • Park, Soyoung;Jea, Ha-Kyung;Min, Ye-Eun;Kang, Jun-Hyeok;Hong, Eun-Been
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.35 no.2
    • /
    • pp.72-81
    • /
    • 2022
  • Objectives : The purpose of this study is to report the case of a bilateral sudden sensorineural hearing loss patient whose hearing had improved by Korean medical treatment combined with threshold sound. Methods : A woman diagnosed with bilateral sudden sensorineural hearing loss has treated with Korean medical interventions(acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and threshold sound conditioning(TSC) for 20 weeks. Pure tone audiometry(PTA) was performed for the evaluation. Results : The average hearing level has improved from mild to normal level. The level of tinnitus has decreased from VAS 10 to VAS 4. Conclusions : We observed an improvement in a bilateral sudden sensorineural hearing loss patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

The Study on Method of Speech Audiometry and the Korean Word Lists Part 1 : Normal Hearing Group (어음청력점사방법과 한국어음청력검사표에 관한 연구)

  • 김기령;김영명;최생이;강대령;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1977.06a
    • /
    • pp.6.1-6
    • /
    • 1977
  • Among the various audiometric test batteries, pure tone and speech audiometry was carried as routine. During the past 20 years, there have been works on speech word list for Korean language. As a preliminary work for standardization of Korean speech word list, the authors are intended to study on the factors of test methods with these proposal speech word lists. Now, authors has studied as followings methods and materials and the results were obtained as followings. A. Materials and Methods a. Word List 1. Paik Chun Kee (Paik) 2. Soh Jin Myoung (Soh) 3. Cynn Kyu Shik (Cynn) 4. Lee Jong Dam (Lee) 5. Hahm Tae Young (Hahm) b. Test Method 1. ascending 2. descending c. Test Material 1. live voice 2. Recorded male voice 3. Recorded female voice B. Results 1. Score of ascending method was better result than descending method. 2. Speech reception threshold and discrimination score were better in recorded female voice, live voice and recorded male voice in that order. 3. Speech reception thresholds among tested word lists were Hahm, Lee, Soh, Cynn and Paik in that order. 4. Discrimination score was highest with Cynn and Lee, Soh, Hahm, Paik in that order.

  • PDF