• 제목/요약/키워드: Pure titanium

검색결과 328건 처리시간 0.023초

LPG 재응축기용 순티타늄 박판의 Nd:YAG 레이저 용접성(I) - 순티타늄의 물성과 용접변수 - (Weldability of Pure Titanium Thin plate for LPG Re-Condenser by Nd:YAG Laser - Physical Constant and Welding Parameter -)

  • 김종도;곽명섭;이창제;김창수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.363-365
    • /
    • 2007
  • Titanium and its alloys have excellent corrosion resistance, high strength to weight ratios and high temperature creep properties, which make them using many various fields of application. Responding to these needs, welding processes for titanium are also being used including TIG, MIG, resistance welding, plasma arc welding, diffusion welding, electron beam welding and laser welding. In this study, It is possible to get sound beads without humping bead and spatter with the decrease of peak power according to increase of pulse width and change of welding speed for heat input control at pulsed Nd:YAG laser welding of titanium plates for Lap welding.

  • PDF

The Influence of Bioactive Inorganic Materials on Osteopontin Expression in Rat Calvarial Osteoblast Culture

  • Mun, Byung-Bae;Jung, Kyoung-Hwa;Chai, Young-Gyu;Kim, Ho-Kun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.652-656
    • /
    • 2007
  • Hydroxyapatite [Ca10(PO4)6(OH)2, HAp] and titanium(Ti) metal are known to be excellent materials with high affinities for natural bone through the apatite. Tricalcium phosphate [Ca3(PO4)2, TCP] is a promising alternative material because it is similar to HAp in its physical properties and biocompatibility. To examine the influence of hydroxyapatite, tricalcium phosphate, pure titanium and pre-treated titanium on osteopontin expression in osteoblasts, RNA was extracted from proliferated and cultured osteoblast cells and OPN mRNA expression was observed by RT-PCR.

수정진동자 미세저울을 위한 티타늄산화물 나노튜브 어레이 (Titanium Oxide Nanotube Arrays for Quartz Ctystal Microbalance)

  • 문규식;양대진;박훈;최원열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.372-372
    • /
    • 2007
  • Titanium oxide nanotube arrays were fabricated by the anodization of pure titanium thin film deposited at $500^{\circ}C$ on silicon substrates. The titania nanotubes were grown by anodization in nonaqueous-base electrolytes at different potentials between 5 V and 30 V. $TiO_2$ nanotube array with a small pore diameter of 40 nm and long titanium oxide layer of $4\;{\mu}m$ was obtained. The $TiO_2$ nanotube array was used as a porous electrode for quartz crystal microbalance (QCM). Nanoporous morphology of electrode will increase the sensitivity of microbalance.

  • PDF

Microgrooves on titanium surface affect peri-implant cell adhesion and soft tissue sealing; an in vitro and in vivo study

  • Lee, Hyo-Jung;Lee, Jaden;Lee, Jung-Tae;Hong, Ji-Soo;Lim, Bum-Soon;Park, Hee-Jung;Kim, Young-Kwang;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제45권3호
    • /
    • pp.120-126
    • /
    • 2015
  • Purpose: With the significance of stable adhesion of alveolar bone and peri-implant soft tissue on the surface of titanium for successful dental implantation procedure, the purpose of this study was to apply microgrooves on the titanium surface and investigate their effects on peri-implant cells and tissues. Methods: Three types of commercially pure titanium discs were prepared; machined-surface discs (A), sandblasted, large-grit, acid-etched (SLA)-treated discs (B), SLA and microgroove-formed discs (C). After surface topography of the discs was examined by confocal laser scanning electron microscopy, water contact angle and surface energy were measured. Human gingival fibroblasts (hGFs) and murine osteoblastic cells (MC3T3-E1) were seeded onto the titanium discs for immunofluorescence assay of adhesion proteins. Commercially pure titanium implants with microgrooves on the coronal microthreads design were inserted into the edentulous mandible of beagle dogs. After 2 weeks and 6 weeks of implant insertion, the animal subjects were euthanized to confirm peri-implant tissue healing pattern in histologic specimens. Results: Group C presented the lowest water contact angle ($62.89{\pm}5.66{\theta}$), highest surface energy ($45{\pm}1.2mN/m$), and highest surface roughness ($Ra=22.351{\pm}2.766{\mu}m$). The expression of adhesion molecules of hGFs and MC3T30E1 cells was prominent in group C. Titanium implants with microgrooves on the coronal portion showed firm adhesion to peri-implant soft tissue. Conclusions: Microgrooves on the titanium surface promoted the adhesion of gingival fibroblasts and osteoblastic cells, as well as favorable peri-implant soft tissue sealing.

Mechanical properties of TiO2/epoxy resin nanocomposites

  • Ahn, Seok-Hwan;Nam, Ki-Woo;Moon, Chang-Kwon
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.69-77
    • /
    • 2013
  • The purpose of this study is to improve the properties of epoxy resin using the big-sized titanium oxide nanoparticles. The effects of particle weight fraction and shape of sample on the thermal and mechanical properties in titanium oxide reinforced epoxy resin has been investigated. In addition, the effect of particle dispersion situation on the mechanical properties of nanocomposites has been studied. As a result, the Tg was almost same regardless of the content of nanoparticles. Storage modulus increased up to the content of 3wt% particles and then decreased. Tensile strength and modulus of film-shaped sample with 1wt% was higher than the one of pure epoxy, while other composites were not. The tensile strength of dogbone-shaped sample with 1wt% was only higher than the one of pure epoxy, while other composites were lower than the one of pure epoxy. Tensile modulus of dogbone-shaped samples increased with the content of particles.

텅스텐아크용접에 의한 Zirconium의 동종 및 이종용접 특성 분석 (Similar and Dissimilar Welding Properties of Zirconium by TIG Welding)

  • 김진영;황효운;이대현;이재관;이동근
    • 열처리공학회지
    • /
    • 제34권4호
    • /
    • pp.165-170
    • /
    • 2021
  • Zirconium has excellent mechanical strength and high heat resistance and excellent corrosion resistance, and it is very important to study zirconium's dissimilar welding properties since it can be used in various applications under harsh environments. Similar welding of pure zirconium and dissimilar metal welding of pure zirconium and pure titanium were performed by TIG welding, and the welding properties were studied in association with microstructural and mechanical properties. In the Zr/Zr welded specimen, sound FZ and HAZ regions showed a basketweave microstructure composed of plate α phase. FZ region of Zr/Ti dissimilar welded specimen exhibited a maximum hardness value of 354.8 Hv, which is about three times higher than that of Ti base metal, due to the precipitation of very fine metastable ω and α phases in the beta matrix. In addition, due to the microstructural continuity in the FZ and HAZ regions, excellent elongation property of 21% was exhibited.

순 티탄늄 판재의 프레스 성형성 평가(제 1보) (Evaluation of press formability of pure titanium sheet)

  • 김영석;인정훈
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.380-388
    • /
    • 2016
  • 본 논문에서는 판형 열교환기 등에 널리 이용되고 있는 순 티타늄 판재의 프레스 성형성을 평가하기 위해 인장실험을 수행하였고 인장실험결과를 가장 잘 피팅할 수 있는 가공경화 모델을 제안하였다. 또한 항복곡면의 도출을 위해 단축변형, 평면변형, 순수전단변형 등 다양한 변형모드 하에서의 인장실험을 실시하였다. 이 제안된 모델을 Hora의 수정된 최대하중조건식에 적용하여 프레스 성형성을 평가하기 위해서 널리 사용되고 있는 성형한계선을 예측하였고 그 결과를 장출성형실험에서 구한 성형한계선과 비교하였다. 도출한 항복곡면을 잘 묘사하기 위한 이방성 항복조건식과 본 연구에서 제안된 가공경화 모델은 순 티타늄 판재의 프레스 성형성의 척도인 성형한계선을 잘 예측함을 알 수 있었다.

순 Ti 박판 GTA 용접부의 기계적 성질 및 성형성에 미치는 공정변수의 영향 (The Effect of Process Variables on Mechanical Properties and Formability in GTA Welds of Commercial Pure Titanium Sheet)

  • 김지훈;홍재근;염종택;박노광;강정윤
    • Journal of Welding and Joining
    • /
    • 제28권4호
    • /
    • pp.73-80
    • /
    • 2010
  • In this work, the effect of welding variables on weldability of gas tungsten arc(GTA) welding was investigated with experimental analysis for a commercial pure(CP) titanium (Grade.1). The GTA welding tests on sheet samples with 0.5mm in thick were carried out at different process variables such as arc length, welding speed and electrode shape. In order to search an optimum arc length with full penetration, bead- on-plate welding before butt-welding were performed with different arc length conditions. From the bead- on-plate welding results, the optimum condition considering arc stability and electrode loss was obtained in the arc length of 0.8mm. Butt-welding tests based on the arc length of 0.8mm were carried out to achieve the optimum conditions of welding speed and electrode shape. Optimum conditions of welding speed and electrode shape were suggested as 10 mm/s and truncated electrode shape, respectively. It was successfully validated by the microstructural observation, tensile tests, micro-hardness tests and formability tests.