• Title/Summary/Keyword: Pupil

Search Result 449, Processing Time 0.022 seconds

Face Detection based on Pupil Color Distribution Maps with the Frequency under the Illumination Variance (빈도수를 고려한 눈동자색 분포맵에 기반한 조명 변화에 강건한 얼굴 검출 방법)

  • Cho, Han-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.225-232
    • /
    • 2009
  • In this paper, a new face detection method based on pupil color distribution maps with the frequency under the illumination variance is proposed. Face-like regions are first extracted by applying skin color distribution maps to a color image and then, they are reduced by using the standard deviation of chrominance components. In order to search for eye candidates effectively, the proposed method extracts eye-like regions from face-like regions by using pupil color distribution maps. Furthermore, the proposed method is able to detect eyes very well by segmenting the eye-like regions, based on a lighting compensation technique and a segmentation algorithm even though face regions are changed into dark-tone due to varying illumination conditions. Eye candidates are then detected by means of template matching method. Finally, face regions are detected by using the evaluation values of two eye candidates and a mouth. Experimental results show that the proposed method can achieve a high performance.

  • PDF

A conceptual introduction and the research of the optical properties of the Telecentric lens system (Telecentric 렌즈계의 이해와 광학적 성능 조사)

  • Kim, Bonghwan;Lim, Hyeonseon;Ji, Taeksang;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, we want to help understanding about telecentric as introducing the concept of the system and researching the optical properties after we choose the designed profile projection lens. An analyzed optical system is F-number=2.8 and the first lens is used negative lens. Accordingly, we can know this system is compacter, because the front focal position is to the inside of the system and aperture stop is designed to the inside of the optical system. The field is about $21^{\circ}$. Since the entrance pupil is located the front focal point, we can certify the exit pupil is -49404.1mm, located on the infinite toward the object space. Therefore, the optical system is the form of 'image space telecentricity'.

  • PDF

Real-Time Multiple Face Detection Using Active illumination (능동적 조명을 이용한 실시간 복합 얼굴 검출)

  • 한준희;심재창;설증보;나상동;배철수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.155-160
    • /
    • 2003
  • This paper presents a multiple face detector based on a robust pupil detection technique. The pupil detector uses active illumination that exploits the retro-reflectivity property of eyes to facilitate detection. The detection range of this method is appropriate for interactive desktop and kiosk applications. Once the location of the pupil candidates are computed, the candidates are filtered and grouped into pairs that correspond to faces using heuristic rules. To demonstrate the robustness of the face detection technique, a dual mode face tracker was developed, which is initialized with the most salient detected face. Recursive estimators are used to guarantee the stability of the process and combine the measurements from the multi-face detector and a feature correlation tracker. The estimated position of the face is used to control a pan-tilt servo mechanism in real-time, that moves the camera to keep the tracked face always centered in the image.

  • PDF

Study of UV-cut Effect by Luminance and Size of pupil in lens (Luminance와 동공크기 변화에 따른 렌즈에서 UV 차단효과 연구)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2001
  • We analyzed the luminance in the visual light region and the size of pupil by the luminance to estimate an UV-A line cut efficiency in the lens. The size of pupil by the luminance(L) was given by ${\Phi}=d-e{\cdot}tanh(f{\cdot}logL)$ and the transmittance efficiency value of a size of pupil was given by $T_r(r)=1-gr^2+hr^4$. We derived the absolute cut efficiency value ${\alpha}$ and the exclusion index $b=(1-{\alpha}){\times}100%$ about the UV-A in the $320{\sim}400nm$ regions. The ${\alpha}$ and b values were obtained respectively 0.018, 0.31, 0.273, 0.153 and 98, 69, 72, 85% of Uv-cut Lens, CR-39, red color and blue color.

  • PDF

Influence of tuition and scholarship on the stop-out rate: An empirical analysis using panel regression model (등록금 및 장학금이 대학생 휴학률에 미치는 영향: 패널회귀모형을 이용한 실증분석)

  • Yang, Hoseok;Choi, Jae-Seok;Han, Jun-Tae;Jeong, Jina
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.3
    • /
    • pp.631-638
    • /
    • 2015
  • In this paper, we configured the panel data of four years using the information of Higher Education In Korea (2010~2013) and studied the influence of tuition and scholarships on the stop-out rate of national university and private university separately through a panel analysis. Three models are implemented considering various variables suck as faculty-student ratios, employment rate, per pupil expenditure, average tuition, and per pupil scholarship. This study showed that the lower net tuition and the higher per pupil off-campus scholarship lowered the stop-out rate at national universities and the lower tuition and the higher per pupil scholarship lowered the stop-out rate at private universities.

Analysis of the Central Corneal Thickness and Anterior Chamber Depth of Eyes in Korean Young Population using the Pentacam (Pentacam을 이용한 한국 청소년 집단에서 각막의 중심두께와 전방깊이 분석)

  • Kim, Douk-Hoon;Bae, Han-Yong
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose. This study was to investigate the analysis of the central corneal thickness and anterior chamber depth of eyes in Korean Young Population using the Pentacam topography. Methods. The subjects consisted of 126 eyes from normal cornea of Korean aged 7-12($8.857{\pm}1.501$) years during 2009. The thinnest location, pachy apex, and pupil central region of the cornea thickness was measured using the Pentacam pachymetry. The anterior chamber depth of normal corneas was measured with Pentacam. Results. The thinnest location of corneal thickness was $547.413{\pm}37.893$um. The pachy apex of cornea thickness was $552.103{\pm}36.016$um. Also, the pupil center of corneal thickness was measured $552.143{\pm}36.418$um. On the other hand, the mean thickness in the central cornea was a statically significant relationship(t-test, p=0.0002) between pachy apex and thinnest zone. Also the mean thickness of the central cornea was a statically significant correlation(pearson p=0.0001) among the pupil center, pachy apex and thinnest zone. The anterior chamber depth was $3.137{\pm}0.308$mm. The mean depth in the anterior chamber of cornea was a statically relationship(t-test, p>0.05) between OD and OS. Conclusions. The results of this clinical study suggested that the analysis of the central corneal thickness and anterior chamber depth using Pentacam in Korean young population can provide the useful morphological information in diagnosis of cornea for the contact lens fitting and corneal refraction surgery.

  • PDF

Real-time pupil motion recognition and efficient character selection system using FPGA and OpenCV (FPGA와 OpenCV를 이용한 실시간 눈동자 모션인식과 효율적인 문자 선택 시스템)

  • Lee, Hee Bin;Heo, Seung Won;Lee, Seung Jun;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.393-394
    • /
    • 2018
  • In this paper, the new system which improve the previously reported "Implementation to human-computer interface system with motion tracking using OpenCV and FPGA" is introduced and in this system, a character selection system for the physically uncomfortable patients is proposed. Using OpenCV, the eye area is detected, the pupil position is determined, and then the results are sent to the FPGA, and the character is selected finally. The method to minimize the pupil movement of the patient is used to output the character according to the user's intention. Using OpenCV, various computer vision algorithms can be easily applied, and using programmable FPGA, a pupil motion recognition and character selection system are implemented with a low cost.

  • PDF

Performance Criterion of Bispectral Speckle Imaging Technique (북스펙트럼 스펙클 영상법의 성능기준)

  • 조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 1993
  • In the case of an imaging system affected by aberrations which are not precisely known, the effect of aberrations can be minimized and near-diffraction-limited images can be restored by introducing artificial random phase fluctuations in the exit pupil of the imaging system and using bispectral speckle imaging. In order to determine the optimum value of the correlation length for Gaussian random phase model, computer simulation is performed for 50 image frames of a point object in the presence of defocus, spherical aberration, coma, astigmatism of 1 wave, respectively. In terms of the criterion of performance, the FWHM of the point spread function, normalized peak intensity, MTF and visual inspection of the restored object are employed. The optimum value for the rms difference $\sigma$ of aberration on the exit pupil in the interval of Fried parameter ${\Upsilon}_0$ is given by 0.27-0.53 wave for spherical aberration, and 0.24-0.36 wave for defocus and astigmatism, respectively. It is found that the bispectral speckle imaging technique does not give good results in the case of coma.

  • PDF

Development of Tracking Equipment for Real­Time Multiple Face Detection (실시간 복합 얼굴 검출을 위한 추적 장치 개발)

  • 나상동;송선희;나하선;김천석;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1823-1830
    • /
    • 2003
  • This paper presents a multiple face detector based on a robust pupil detection technique. The pupil detector uses active illumination that exploits the retro­reflectivity property of eyes to facilitate detection. The detection range of this method is appropriate for interactive desktop and kiosk applications. Once the location of the pupil candidates are computed, the candidates are filtered and grouped into pairs that correspond to faces using heuristic rules. To demonstrate the robustness of the face detection technique, a dual mode face tracker was developed, which is initialized with the most salient detected face. Recursive estimators are used to guarantee the stability of the process and combine the measurements from the multi­face detector and a feature correlation tracker. The estimated position of the face is used to control a pan­tilt servo mechanism in real­time, that moves the camera to keep the tracked face always centered in the image.

A Study for Detecting a Gazing Point Based on Reference Points (참조점을 이용한 응시점 추출에 관한 연구)

  • Kim, S.I.;Lim, J.H.;Cho, J.M.;Kim, S.H.;Nam, T.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.250-259
    • /
    • 2006
  • The information of eye movement is used in various fields such as psychology, ophthalmology, physiology, rehabilitation medicine, web design, HMI(human-machine interface), and so on. Various devices to detect the eye movement have been developed but they are too expensive. The general methods of eye movement tracking are EOG(electro-oculograph), Purkinje image tracker, scleral search coil technique, and video-oculograph(VOG). The purpose of this study is to embody the algorithm which tracks the location of the gazing point at a pupil. Two kinds of location data were compared to track the gazing point. One is the reference points(infrared LEDs) which is effected from the globe. Another is the center point of the pupil which is gained with a CCD camera. The reference point was captured with the CCD camera and infrared lights which were not recognized by human eyes. Both of images which were thrown and were not thrown an infrared light on the globe were captured and saved. The reflected reference points were detected with the brightness difference between the two saved images. In conclusion, the circumcenter theory of a triangle was used to look for the center of the pupil. The location of the gazing point was relatively indicated with the each center of the pupil and the reference point.