• Title/Summary/Keyword: Pupil's Size

Search Result 34, Processing Time 0.025 seconds

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

EFFECT OF MONO-SPECTRAM RADIANT ON AUTONOMIC NERVOUSSYSTEM

  • Shibayama, Y.;Watanuki, S.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.62-66
    • /
    • 2000
  • This study investigated the effects of certain specific wavelengths of lighting on the autonomic nervous system (ANS) using the heart rate variability (HRV) as an index. Six subjects with normal color vision participated n this study between 15:00 and 17:00 hr to neutralize any visual differences arising from circadian rhythm. The environmental conditions of the laboratory were maintained in complete darkness and the temperature was equilibrated at 24$\Box$ with a relative humidity of 60%. Subjects were only subjected to light stimulation when the pupil of dyes attained a minimum size of 2 mm by projecting illumination equalized with the same spectral radiance of 500-700 nm with 50-nm internal radiance. HRV was calculated from electrocardiogram (ECG) with systematic respiratory control at 0.35 Hz. The results suggest that illumination with certain wavelengths may induce ANS activation.

  • PDF

Effectiveness of Road Lighting on Driver' Vision (도로조명 방식이 운전자 시지각에 미치는 영향)

  • Jeong, Jun-Hwa;Lee, Suk-Ki;Kim, Won-Sik;Lee, Mi-Ae
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.125-131
    • /
    • 2012
  • PURPOSES : Road lighting facilities increase the visibility of road at night in order to improve traffic driver safety and comfort. Generally speaking, current pole lighting has a tendency to create problems of glare and flicker. The phenomenon of glare gives discomfort due to increase of scattered light, when high luminance is in driver's field of view. The phenomenon of flicker occurs due to the driver passing through discontinuous pockets of pole lighting areas. These phenomenon increase eye strain and decrease driver safety. METHODS : Low height line lighting that distributes light lower than driver's eye level has been developed and evaluated to reduce the problems linked to current pole lighting. A test was undertaken with 4 conditions(turn on the general pole lighting, turn off alternate pole lighting, turn on the line lighting and line lighting with 50% dimming). A driver written survey was conducted in order to gain driver feedback. RESULTS : Pupil size and brow frequency compared with degree in pole lighting are reduced. CONCLUSIONS : Low height line lighting environment makes drivers more comfortable than pole lighting environment and is positive lighting method in the energy saving and landscape aspect.

The effects of the usability of products on user's emotions - with emphasis on suggestion of methods for measuring user's emotions expressed while using a product -

  • Jeong, Sang-Hoon
    • Archives of design research
    • /
    • v.20 no.2 s.70
    • /
    • pp.5-16
    • /
    • 2007
  • The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this study we have extracted some emotional words that can come up during user interaction with a product and reveal emotional changes through three methods. Finally, we extracted 88 emotional words for measuring user's emotions expressed while using products. And we categorized the 88 words to form 6 groups by using factor analysis. The 6 categories that were extracted as a result of this study were found to be user's representative emotions expressed while using products. It is expected that emotional words and user's representative emotions extracted in this study will be used as subjective evaluation data that is required to measure user's emotional changes while using a product. Also, we proposed the effective methods for measuring user's emotion expressed while using a product in the environment which is natural and accessible for the field of design, by using the emotion mouse and the Eyegaze. An examinee performs several tasks with the emotion mouse through the mobile phone simulator on the computer monitor connected to the Eyegaze. While testing, the emotion mouse senses user's EDA and PPG and transmits the data to the computer. In addition, the Eyegaze can observe the change of pupil size. And a video camera records user's facial expression while testing. After each testing, a subjective evaluation on the emotional changes expressed by the user is performed by the user him/herself using the emotional words extracted from the above study. We aim to evaluate the satisfaction level of usability of the product and compare it with the actual experiment results. Through continuous studies based on these researches, we hope to supply a basic framework for the development of interface with consideration to the user's emotions.

  • PDF

General Pharmacology of $^{13}C$-Urea Powder Preparation in ${Helikat}^{TM}$

  • Lee, Eun-Bang;Cho, Sung-Ig;Jung, Chun-Sik
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.406-411
    • /
    • 1998
  • The pre-mixed $_{13}C$-urea powder preparation in ${Helikit}_{TM}$ for test of Helicobacter pylori was evaluated for pharmacological properties. The oral doses of the preparation used in mice were 30-fold as compared to human doses. The results obtained in the present study demonstrate that spontaneous movement, hexobarbital-induced hypnosis, rotarod performance, body temperature, acetic acid-induced writhing syndrome, chemical and electroshock convulsion, pupil size and intestinal propulsion had not been affected at the oral doses of 230, 700 and 2100 mg/kg in mice. The blood pressure was slightly elevated as given intravenously in rats at a dose of 5 mg/kg of the preparation, but respiration was not influenced at the dose. In isolated guinea pig ileum and rat fundus preparation, the preparation at a concentration of $1{\times}10^{4}$ g/ml neither caused any direct effect nor inhibited the contraction produced by acetylcholine, histamine or 5-hydroxytryptamine. These results reported here provide evidence that pre-mixed $^{13}C$ 13/C-urea powder preparation is free of general pharmacological properties performed in oral administration.

  • PDF

Visual Perception Experiment Study on the Brand Effect - Comparison of Domestic and Imported Car Brand -

  • Im, Hajin;Kim, Chiyoung;Kim, Soojung;Yu, Sooyeon;Kwon, Mahnwoo
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.1
    • /
    • pp.146-154
    • /
    • 2021
  • Conspicuous consumption is often investigated in Korea and consumers purchase a product to publicly display economic power or social status. The existing studies argue that brand loyalty and luxury brand preferences escalate conspicuous consumption, and it is important to identify different visual perception to understand irrational consumers' behavior. Car emblem as brands' visual identity represents the brand's image, mission and message. Irrational consumers thus are expected have different visual perception to the emblem or logo. To understand the impact of irrational consumer behavior on visual perception, this study explored how brand loyalty and luxury brand preferences impact on the visual perception of car emblems between Korean domestic brand and imported brand. This study used eye tracking technology to measure the respondents' attention on an emblem of the cars. Eye tracking tools analyze fixations and measure the attention on a specific area of interests (AOI). This study explored the maintaining time and frequency on AOI, as well as explored the size of pupil to identify the respondents' attention on the AOI. In this experiment, the logos of domestic cars (i.e., Hyundai and Kia) and foreign cars (i.e., Mercedes-Benz and BMW) were swapped to see how irrational consumer behavior impact on visual perception of car emblem.

Effect of Driver's Cognitive Distraction on Driver's Physiological State and Driving Performance

  • Kim, Jun-Hoe;Lee, Woon-Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.371-377
    • /
    • 2012
  • Objective: The aim of this study is to investigate effect of driver's cognitive distraction on driver's physiological state and driving performance, and then to determine parameters appropriate for detecting the cognitive distraction. Background: Driver distraction is a major cause of traffic accidents and poses a serious threat to traffic safety due to ever increasing use of in-vehicle information systems and mobile phones during driving. Cognitive distraction, among four different types of distractions, prevents a driver from processing traffic information correctly and adapting to change in surround vehicle behavior in time. However, the cognitive distraction is more difficult to detect because it normally does not involve significant change in driver behavior. Method: A full-scale driving simulator was used to create virtual driving environment and situations. Participants in the experiment drove the driving simulator in three different conditions: attentive driving with no secondary task, driving and conducting secondary task of adding numbers, and driving and conducting secondary task of conversing with an experimenter. Parameters related with driver's physiological state and driving performance were measured and analyzed for their change. Results: The experiment results show that driver's cognitive distraction, induced by secondary task of addition and conversation during driving, increased driver's cognitive workload, and indeed brought change in driver's physiological state and degraded driving performance. Conclusion: The galvanic skin response, pupil size, steering reversal rate, and driver reaction time are shown to be statistically significant for detecting cognitive distraction. The appropriate combination of these parameters will be used to detect the cognitive distraction and estimate risk of traffic accidents in real-time for a driver distraction warning system.

Prediction of Alcohol Consumption Based on Biosignals and Assessment of Driving Ability According to Alcohol Consumption (생체 신호 기반 음주량 예측 및 음주량에 따른 운전 능력 평가)

  • Park, Seung Won;Choi, Jun won;Kim, Tae Hyun;Seo, Jeong Hun;Jeong, Myeon Gyu;Lee, Kang In;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.27-34
    • /
    • 2022
  • Drunk driving defines a driver as unable to drive a vehicle safely due to drinking. To crack down on drunk driving, alcohol concentration evaluates through breathing and crack down on drinking using S-shaped courses. A method for assessing drunk driving without using BAC or BrAC is measurement via biosignal. Depending on the individual specificity of drinking, alcohol evaluation studies through various biosignals need to be conducted. In this study, we measure biosignals that are related to alcohol concentration, predict BrAC through SVM, and verify the effectiveness of the S-shaped course. Participants were 8 men who have a driving license. Subjects conducted a d2 test and a scenario evaluation of driving an S-shaped course when they attained BrAC's certain criteria. We utilized SVR to predict BrAC via biosignals. Statistical analysis used a one-way Anova test. Depending on the amount of drinking, there was a tendency to increase pupil size, HR, normLF, skin conductivity, body temperature, SE, and speed, while normHF tended to decrease. There was no apparent change in the respiratory rate and TN-E. The result of the D2 test tended to increase from 0.03% and decrease from 0.08%. Measured biosignals have enabled BrAC predictions using SVR models to obtain high Figs in primary and secondary cross-validations. In this study, we were able to predict BrAC through changes in biosignals and SVMs depending on alcohol concentration and verified the effectiveness of the S-shaped course drinking control method.

A Case of Delayed Administration of Naloxone for Morphine Intoxicated Patient (Morphine 과량복용 후 중독증상을 보인 환자의 지연된 Naloxone 치료 1례)

  • Kim, Gun-Bea;Park, Won-Nyung;Gu, Hong-Du
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.1
    • /
    • pp.33-36
    • /
    • 2012
  • Opioids are the one of the most commonly used drugs to control cancer pain all over the world. But, we should not overlook the potential risk of opioid intoxication because they have well-known detrimental side effects. The opioid intoxication can be diagnosed thorough various clinical manifestations. The altered mental status, respiratory depression, and miosis is very representative clinical features although these symptoms don't always appear together. Unfortunately the opioid-toxidrome can be varied. A 42 years old man came to our emergency room after taking about 900 mg morphine sulfate per oral. He was nearly alert and his respiration was normal. Even though his symptoms didn't deteriorated clinically, serial arterial blood gas analysis showed increase in PaCO2. So we decided to use intravenous naloxone. Soon, he was fully awaked and his pupils size was increased. After a continuous infusion of intravenous naloxone for 2 hours, PaCO2 decreased to normal range and his pupil size also returned to normal after 12 hours. Though the levels of serum amylase and lipase increased slightly, his pancreas was normal according to the abdominal computed tomography. He had nausea, vomit, and whole body itching after naloxone continuous infusion, but conservatively treated. We stopped the continuos infusion after 1 day because his laboratory results and physical examinations showed normal. As this case shows, it is very important to prescribe naloxone initially. If you suspect opioid intoxication, we recommend the initial use of naloxone even though a patient has atypical clinical features. In addition, we suggest intranasal administration of naloxone as safe and effective alternative and it's necessary to consider nalmefene that has a longer duration for opioid intoxication.

  • PDF

A Study on Iris Recognition by Iris Feature Extraction from Polar Coordinate Circular Iris Region (극 좌표계 원형 홍채영상에서의 특징 검출에 의한 홍채인식 연구)

  • Jeong, Dae-Sik;Park, Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.3
    • /
    • pp.48-60
    • /
    • 2007
  • In previous researches for iris feature extraction, they transform a original iris image into rectangular one by stretching and interpolation, which causes the distortion of iris patterns. Consequently, it reduce iris recognition accuracy. So we are propose the method that extracts iris feature by using polar coordinates without distortion of iris patterns. Our proposed method has three strengths compared with previous researches. First, we extract iris feature directly from polar coordinate circular iris image. Though it requires a little more processing time, there is no degradation of accuracy for iris recognition and we compares the recognition performance of polar coordinate to rectangular type using by Hamming Distance, Cosine Distance and Euclidean Distance. Second, in general, the center position of pupil is different from that of iris due to camera angle, head position and gaze direction of user. So, we propose the method of iris feature detection based on polar coordinate circular iris region, which uses pupil and iris position and radius at the same time. Third, we overcome override point from iris patterns by using polar coordinates circular method. each overlapped point would be extracted from the same position of iris region. To overcome such problem, we modify Gabor filter's size and frequency on first track in order to consider low frequency iris patterns caused by overlapped points. Experimental results showed that EER is 0.29%, d' is 5,9 and EER is 0.16%, d' is 6,4 in case of using conventional rectangular image and proposed method, respectively.