• Title/Summary/Keyword: Puncture

Search Result 480, Processing Time 0.036 seconds

NOTES ON MDS SELF-DUAL CODES

  • Han, Sunghyu
    • Journal of applied mathematics & informatics
    • /
    • v.30 no.5_6
    • /
    • pp.821-827
    • /
    • 2012
  • In this paper, we prove that for all odd prime powers $q$ there exist MDS(maximum distance separable) self-dual codes over $\mathbb{F}_{q^2}$ for all even lengths up to $q+1$. Additionally, we prove that there exist MDS self-dual codes of length four over $\mathbb{F}_q$ for all $q$ > 2, $q{\neq}5$.

Electrical Treeing Phenomena at the Interface of Conductor and Insulator (도전체와 절연체 계면에서의 전기트링 현상)

  • 조영신;심미자;김상욱
    • Journal of Surface Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.236-242
    • /
    • 1995
  • This paper describes a study of electrical tree growth in DGEBA/MDA/SN system subjected to ac high electric field. The dielectric breakdown process, which consists of tree initiation, tree propagation and the complete puncture of the system was investigated. Dielectric breakdown always initiated from the needle tip where the electric field reinforcement is the highest. Higher temperature and voltage accelerated the tree growth and reduced the time to breakdown.

  • PDF

The Effects of Fowler's Position Change on Back Pain and Discomfort of the Patients Following Percutaneous Coronary Intervention (경피적 관상동맥중재술 후 반좌위 체위변경이 환자의 요통과 불편감에 미치는 효과)

  • Nam, So-Young;ChoiKwon, Smi
    • Perspectives in Nursing Science
    • /
    • v.7 no.1
    • /
    • pp.55-64
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the effects of position change from supine to Fowler's on back pain and discomfort in patients who remained on bed rest after undergoing PCIs with a vascular closure device. Methods: Data was collected from 35 inpatients who were hospitalized in coronary-care unit to perform PCIs with a vascular closure device at S hospital in Seoul from December, 2006 to May, 2007. Back pain, discomfort, presence and grade of bleeding and hematoma from femoral arterial puncture site and blood pressure/pulse rate were measured prior to, 10 minutes, 1 hour and 2 hours after position change. Data was analyzed with descriptive statistics, $x^2$ tests and t-tests using SPSS/WIN 12.0 for Windows program. The level of significance (${\alpha}$) was set at 0.05 for this study. Results: We found that there was no significant difference in back pain and discomfort in 10 minutes after position change between the two groups. However, the experimental group reported significantly less back pain and discomfort than the control group in 1 hour (p<.01, respectively) and 2 hour (p<.01, respectively) after position change. There was no significant difference in the presence and grade of bleeding and hematoma at the puncture site, blood pressure, and pulse rate in 10 minutes, 1hour and 2hours after position change between the two groups. Conclusion: Fowler's position change after PCIs in, therefore, safe and effective method of reducing back pain and physical discomfort without causing additional bleeding and changes in blood pressure and pulse rate.

  • PDF

A Study on Perceived Discomfort in Patients Following Cardiac Catheterization (심도자 검사 환자의 불편감에 관한 연구)

  • 이은자
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.124-140
    • /
    • 1995
  • Cardiac cathererization has become a routine diagnostic procedure indicated for evaluation of a wide varity of cardiac conditions. Patients are admitted to the coronary care unit after cardiac catheterization. These conscious patients report feeling uncomfortable in the CCU, but no studies have been done on the effects of bed rest, sand bags on the femoral puncture site and restricted mobility for 4 to 12 hours or longer postprocedure. The main objective of this thesis is to provide basic data to nursing on interventions which de-crease the uncomfortableness experienced by patients in the CCU following cardiac catheterization. In this phenomenological study, the various discomforts felt by the patients were collected and classified. The study subjects were a convenience sample of 29 patients who were admitted to the CCU of a general hospital in Inchon following cardiac catheterization. They were conscious, so they were able to communicate without difficulty. The data were collected over an U days period from July 21, to October 14, 1994. The subjects were interviewed using unstructured open questions and the interviews were tape recorded with the patient's permission The data were analyzed using the Van Kaams phenomenological method. Reliability and validity were exammed by two professor of nursing science, one head nurse, one staff nurse and one cardiologist. The results of the study are summarized as follows ; 1. The 129 descriptive statements by the postcardiac catheterization patients of discomfort were organized into 19 themes. 2. The 19 themes were divided into 3 categories ; physical, psychological, and environmental aspects. 3. The problems concerning the physical aspect were the discomfort of restriction of movement, dysuria, medical devices, pain in the puncture site, symptom is related to the procedure of cardiac catheterization, headache and dizziness, leg painand tingling sensation, and chest pain. The problems concerning the psychological aspect were regret resulting from dependency, economic burden, dissatisfaction with medical personnel, dissatisfaction with medical service system, anxiety about the result of the procedure, concern about the prognosis, loneliness, and concern over treatment procedure. The problems concerning the environmental aspect were influence from neighboring patients, noise, and maladaptation to environmental change. The necessity for holistic care which satisfies physical, psychological, and environmental need must be emphasized in order to solve these discomforts.

  • PDF

Assessment of the Optimal Site of Femoral Artery Puncture and Angiographic Anatomical Study of the Common Femoral Artery

  • Ahn, Ho-Young;Lee, Hyung-Jin;Lee, Hong-Jae;Yang, Ji-Ho;Yi, Jin-Seok;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate demographic and clinical factors affecting the common femoral artery diameter and length, and anatomical relationship between the femoral head and the common femoral artery during angiography. Methods : We retrospectively reviewed 109 femoral angiograms. We collected the clinical data of the patients and estimated the common femoral artery diameter and length. We divided the areas in the angiogram from cephalic to caudal direction (zone 0 to 5). The lowest levels of the inferior epigastric artery loop and points of the common femoral artery bifurcation were checked. Results : The luminal diameter of the common femoral artery was $6.19{\pm}1.20mm$. Height, weight, body surface area, as well as common femoral artery diameter were significantly greater in men than in women (p<0.005). The length of the common femoral artery was $27.59{\pm}8.87mm$. Height, weight and body surface area showed strong positive relationships with common femoral artery diameter. All of the inferior epigastric artery loops were located above the center of the femoral head. The point of common femoral artery bifurcation was above the center of the femoral head in 4.59% of femoral angiograms. Conclusions : Males and patients with a high body surface area have a larger common femoral artery diameter. The cumulative probability of optimal targeting between the lowest margin of the inferior epigastric artery loop and the common femoral artery bifurcation is the highest in zone 3 puncture.

Efficacy of Transradial Cerebral Angiography in the Elderly

  • Park, Jung-Hyun;Kim, Dae-Yong;Kim, Jin-Wook;Park, Yong-Seok;Seung, Won-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.213-217
    • /
    • 2013
  • Objective : Transradial angiography has become popular among many cardiologists as a diagnostic and therapeutic tool. However, transradial cerebral angiography is not utilized to the same extent. The purpose of this study is to present our experience regarding the usefulness of transradial cerebral angiography, especially in elderly patients. Methods : Between May 2011 and February 2012, a total of 126 cerebral angiographies were performed via a transradial approach in a single center. Of them, only 47 patients were over 60 years old. In our institution, we shifted the initial access from the right femoral artery to the right radial artery in all patients requiring cerebral angiography in 2011. We did not attempt radial access in 40 cases for variable reasons. Results : The procedural success rate was 92.2%. We have four failures of transradial angiography; two because of loop formations of the radial and brachial artery and two due to multiple puncture failures. All supra-aortic vessels were successfully catheterized. However, the selective catheterization rates of the left side distal vessels were lower, as success rates were 89.7% for the right internal carotid artery and 75% for the left internal carotid artery. Procedure-related vascular complications, such as puncture site hematoma, hand ischemia, pseudoaneurysm, arteriovenous fistula and arterial dissection were not observed in our series. However, intraprocedural thrombosis developed in one patient, which was resolved completely by intraarterial thrombolytic agents. Conclusion : With advancing patient's age, we believe that transradial cerebral angiography is a useful tool to decrease patient's discomfort and more effectively manage the vessel tortuosity.

Changes of Texture, Soluble Solids and Protein during Cooking of Soybeans (콩의 조리과정 중 텍스쳐, 고형물 및 단백질의 변화)

  • Kim, Young-Ok;Jung, Hae-Ok;Rhee, Chong-Ouk
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.192-198
    • /
    • 1990
  • Texture, losses of total solids and proteins o) soybeans were studied during cooking at $100-135^{\circ}C$. The textural changes were measured using the puncture probe with an Instron Universal Testing Machine, and changes in microstructure of beans were observed with scanning electron microscopy during the cooking. The major effect observed was a breakdown of the cell walls and appearance of the protein bodies with soaking process. As the cooking time at $100^{\circ}C$ is longer, the separation of cells and changes in cell shape could be seen in the sample. The greater amounts of soluble solids were leached out with longer coo king time from the beans.

  • PDF

Effect of Sodium Acetate and Calcium Chloride on Characteristics of Kakdugj (Sodium Acetate와 Calcium Chloride를 첨가한 깍두기의 특성)

  • Um, Jin-Young;Kim, Kwang-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.140-144
    • /
    • 1990
  • This study was undertaken to examine if sodium acetate and/or calcium chloride would increase the firmness and/or retard rancidity of Kakdugj (Korean seasoned pickles of cubed radish roots) during short $(at\;20^{\circ}C)$ or long $(at\;4^{\circ}C)$ period of fermentation During the fermentation periods, pH and acidity were higher in Kakdugis containing 0.3 or 0.6% Na-acetate than in the other samples at both storage temperatures. Firmness was increased with addition of 0.05% Calcium chloride and synergistic effect on firmness was observed when Calcium chloride and Na-acetate were added together. Sourness did not decreased in samples containing 0.3% Na-acetate at either fermentation periods but decreased in those containing 0.6% Na-acetate and stored for long. Saltiness was increased slightly with the addition of Calcium chloride. Compression test gave closer result to sensory evaluation than puncture test In the measurement of firmness with Instron.

  • PDF

Rabbit Model for in vivo Study of Intervertebral Disc Degeneration and Regeneration

  • Kong, Min-Ho;Do, Duc-H.;Miyazaki, Masashi;Wei, Feng;Yoon, Sung-Hwan;Wang, Jeffrey C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.5
    • /
    • pp.327-333
    • /
    • 2008
  • Objective: The purpose of this study is to verify the usefulness of the rabbit model for disc degeneration study. Materials: The L1-L2, L2-L3, L3-L4. or L4-L5 lumbar intervertebral disc (IVD) of 9 mature male New Zealand White rabbits were injured by inserting a 16-gauge needle to a depth of 5 mm in the left anterolateral annulus fibrosus while leaving L5-L6 IVD uninjured. Three other rabbits also received intradiscal injections of rabbit disc cells transfected with adenovirus and bone morphogenetic protein-2 (ad-BMP-2) at L4-L5 in addition to injury by 16-gauge needle at the L1-L2 level. Using digitized radiographs, measurements of IVD height were made and analyzed by using the disc height index (DHI). Magnetic resonance imaging (MRI) scans of the injured discs, injected discs, and uninjured L5-L6 discs were performed at 15 weeks post surgery and compared with preoperative MRI scans. Results: All twelve rabbits showed consistent results of disc degeneration within 15 weeks following annular puncture. DHIs of injured discs were significantly lower than that of the uninjured L5-L6 discs (p<0.05). The mean value of disc degeneration grade of injured discs was significantly higher than that of uninjured discs (p<0.05). The injection of disc cell transfected with ad-BMP-2 did not induce disc regeneration at 15 weeks after injection. Conclusion: This study showed that the injured disc had a significant change in DHI on simple lateral radiograph and disc degeneration grade on MRI scans within 15 weeks in all rabbits. Rabbit annular puncture model can be useful as a disc degeneration model in vivo.

Morphological Assessment of Cadaveric Radial, Brachial and Subclavian Arteries : A Neurointerventional Approach

  • Yilmaz, Ali;Ozkul, Ayca;Shin, Dong Seong;Im, Soo-Bin;Yoon, Seok-Mann;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.499-503
    • /
    • 2015
  • Objective : The transradial catheterization (TRC) is becoming widespread, primarily for neurointerventions. Therefore, the evaluation of radial artery puncture in clinical practice and a better understanding of the anatomy are important to improve the safety of neuroendovascular surgery. Methods : Ten formalin-fixed adult Korean cadavers were dissected to expose radial artery (RA), brachial artery (BrA) and subclvian artery (ScA), bilaterally. Vessel lengths and diameters were meaured using a caliper and distance between the specific point of vessels and the anatomical landmarks including the radial styloid process, the medial epicondyle of the humerus, the sternoclavicular joint, and the vertebral artery orifice were also measured. Results : The average length between the radial (RAPS) and the BrA puncture sites (BrAPS) and between the vertebral artery orifice (VAO) and the BrA bifurcation (BrAB) did not differ between sides (p>0.05). The average length between the radial styloid process (RSP) and the RAPS was $13.41{\pm}2.19mm$, and the RSP was $26.85{\pm}2.47mm$ from the median nerve (MN). The mean length between the medial epicondyle (ME) and the BrAPS as $44.23{\pm}5.47mm$, whereas the distance between the ME and the MN was $42.23{\pm}4.77mm$. The average VAO-ScA angle was $70.94{\pm}6.12^{\circ}$, and the length between the ScA junction (SCJ) and the VAO was $60.30{\pm}8.48mm$. Conclusion : This study provides basic anatomical information about the radial artery and the brachial route and can help improving new techniques, selection of size and shape of catheters for TRC. This can help neurointerventionists who adopt a transradial neuroendovascular approach and offers comprehensive and safe care to their patients.