• 제목/요약/키워드: Pumping speed

검색결과 160건 처리시간 0.025초

Counter-Rotating Type Pumping Unit (Impeller Speeds in Smart Control)

  • Kanemoto, Toshiaki;Komaki, Keiichi;Katayama, Masaaki;Fujimura, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권3호
    • /
    • pp.334-340
    • /
    • 2011
  • Turbo-pumps have weak points, such as the pumping operation is unstable on the positive slope of the head curve and/or the cavitation occurs at the low suction head. To improve simultaneously both weak points, the first author invented the unique pumping unit composed of the tandem impellers and the peculiar motor with the double rotational armatures. The front and the rear impellers are driven by the inner and the outer armatures of the motor, respectively. Both impeller speeds are automatically and smartly adjusted in response to the pumping discharge, while the rotational torques between both impellers/armatures are counter-balanced. Such speeds contribute to suppress successfully not only the unstable operation at the low discharge but also the cavitation at the high discharge, as verified with the axial flow type pumping unit in the previous paper. Continuously, this paper investigates experimentally the effects of the tandem impeller profiles on the pump performances and the rotational speeds against the discharge, using the impellers whose loads are low and/or high at the normal discharge. The worthy remarks are that (a) the unstable operation is suppressed as expected and the shut off power is scarcely large in the smart control, (b) the blade profile contributes to determine the discharge giving the maximum/minimum rotational speed where the reverse flow may incipiently appears at the front impeller inlet, (c) the tandem impeller profiles scarcely affect the rotational speeds, while the loads of the front and the rear impellers are same, but (d) the impeller with the low load must run faster and the impeller with the high load must run slower at the same discharge to take the same rotational torque, and (e) the reverse flow at the inlet and the swirling velocity component at the outlet of the front impeller with the high load require making the rotational speed of the rear impeller with low load fairly faster at the lower discharge.

터보분자펌프(TMP) 배기속도 측정에 관한 고찰 (Study on the Measurement of TMP Pumping Speed)

  • 강상백;신진현;차덕준;고득용;정완섭;임종연
    • 한국진공학회지
    • /
    • 제19권4호
    • /
    • pp.249-255
    • /
    • 2010
  • 터보분자펌프(TMP)의 특성평가는 ISO, PNEUROP, DIN, JIS, AVS 등 세계 여러 나라의 표준제정기구에서 제정한 국제규격에 그 근거를 두고 있다. 한국표준과학연구원에서는 이러한 국제규격에 기반을 둔 터보분자펌프의 특성평가시스템을 자체 설계/제작하여 그 신뢰성을 확인하기 위해 개발품 및 상용품의 평가에 주력하고 있다. 터보분자펌프의 배기속도 측정방법으로서 기체흐름 영역에 따른 throughput method와 orifice method를 적용하고 있으나 측정게이지, 유량계 및 orifice conductance의 불확도 등 실질적으로 정확한 배기속도를 제시하기 위한 조건들의 제약 때문에 많은 측정오차를 포함하고 있다고 볼 수 있다. 이러한 배기속도의 측정오차를 줄이기 위한 하나의 고찰로서 본 논문에서는 $10^{-1}$ Pa-L/s 영역까지의 유량 주입범위를 가지는 기 구축된 정적법을 이용한 유량주입에 기반을 둔 throughput method를 이용하여 1000 L/s TMP의 측정 능력을 검증하고자 한다. 또한 분자류 영역인 orifice method를 사용할 경우 고진공영역, 미세유량 주입영역으로 진입할수록 커질 수밖에 없는 배기속도 측정 불확도를 최소화시키기 위해 검증된 유량을 이용한 conductance 값을 제시하여, 기 언급한 두 가지 배기 속도 측정 방법의 연속성을 유지하기 위한 실험적인 방법론을 제기하고자 한다.

Large Cryosorption Pump for the NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.27-32
    • /
    • 2003
  • A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.

  • PDF

콘크리트의 레올로지 특성 및 펌핑조건에 따른 펌프압송특성에 관한 연구 (A Study on the Pumping Characteristics according to Pumping Method and Rheology Characteristics of Concrete)

  • 권대훈;정웅택;김형래;조호규;전준영;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.99-101
    • /
    • 2011
  • In order to have pumping technology for high speed construction of tall building, study for quantitative evaluation of flow characteristics and pumpability should be conducted. So, this study evaluate the characteristics among the inner pipe pressure, fresh concrete properties and separated mortar through the continuous pumping test. Then it consider of relations between rheological properties and pumpability. In the result of test, it found that there are high interrelationship between the rheological characteristics which represented plastic viscosity and pressure lose by pipe length.

  • PDF

TMP 1000L/s 급 database 구축 및 종합특성평가시스템 진단 기술 개발

  • 강상백;신진현;차덕준;정완섭;임종연
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.335-335
    • /
    • 2010
  • 한국표준과학연구원 진공센터에서는 국제규격에 바탕을 둔 저진공펌프 종합특성평가시스템을 구축하여 $1100mbar\;{\sim}\;10^{-3}mbar$ 압력 영역에서의 저진공펌프(roots, dry 등)류의 종합특성평가를 시행하고 있다. 저진공펌프 종합특성평가시스템은 국제적 절차에 따른 신뢰성을 바탕으로 구축하고 있으나, 한국표준과학연구원 진공센터 뿐만 아니라, 국내에서도 고진공 종합특성평가 시스템을 구축 하고 있지 않다. 이에 반도체/디스플레이 등 첨단 공정에서 진공 환경을 조성하는 핵심장비인 고진공펌프의 종합특성평가시스템을 개발하고자 터보펌프(TMP) 1000L/s 급의 database를 구축 하였다. 터보펌프(TMP)는 throughput method와 orifice method 두 가지 방법을 병행하여 pumping speed 측정한다. orifice method는 일종의 미세유량 측정 장치이며, 실험값과 계산값 유량의 오차 범위가 작고 신뢰성을 확보하면 throughput method 만으로 측정할 수 있다. Througput method는 $10^{-6}mbar$ 압력 이상의 영역을 측정하며, ultimate pressure 및 $150^{\circ}C$의 bake-out 을 진행하여 base pressure을 측정 할 수 있으며, $10^{-6}mbar$ 압력 이상의 pumping speed를 측정 할 수 있다. 이에 따른 정압형 유량시스템을 개발 중에 있으며, inlet pressure와 outlet pressure를 이용한 compression ratio를 측정 한다. Orifice method는 ultimate pressure와 base pressure을 측정하며, leak valve를 이용한 컨덕턴스(C)로 pressure ratio을 이용하여 유량값을 계산하며, $10^{-6}mbar$ 압력 이하의 pumping speed를 측정할 수 있다. 또한 throughput method와 orifice method의 pumping speed 뿐만 아니라 소비전력 및 소음, 진동, 온도 등 특성평가 관련 사항들의 전반적인 사항을 평가하여 터보펌프(TMP) 1000L/s 급의 database를 구축한다. 향후 예비 실험을 통한 고진공펌프의 종합특성평가시스템을 완비해 나가며, 고진공펌프 종합 특성평가시스템을 통하여 국제적으로 공인받을 수 있는 평가기준을 확립하고 그 기준에 의한 진공/기계적 성능의 전방위적인 종합특성진단과 공정대응성 평가 등 국제적 기술 신뢰성을 확보하고자 한다.

  • PDF

Experimental study on variation in rheological properties of concrete subjected to pressure and shearing by pumping

  • Jung Soo Lee ;Kyong Pil Jang ;Chan Kyu Park ;Seung Hee Kwon
    • Advances in concrete construction
    • /
    • 제16권1호
    • /
    • pp.59-68
    • /
    • 2023
  • In the pumping process, concrete moves along the pipe and experiences both pressure and shear. This changes the workability and flow characteristics of the concrete. However, the effect of pressure and shear on the change in properties of concrete during the pumping process has not yet been accurately identified. This study analyzed the effects of pressure and shear on the properties of concrete during pumping. For quantitative tests, lab-scale test equipment capable of simulating the pressure and shear applied to concrete during pumping was used. For one coarse aggregate type, two paste types, three mortar types, and five concrete types, the effects of pressure, shear, and shear under pressure conditions were examined by varying the maximum pressure (0 to 200 bar) and the rotational speed of the vane for shear (0 to 180 rpm). Under the maximum pressure condition of 200 bar, the water absorption of coarse aggregate increased by 0.62% and that of fine aggregate also increased. When the concrete was under pressure, significant changes (a reduction in a slump and an increase in viscosity and yield stress) compared with the effect of the elapsed time occurred owing to an increase in the water absorption of the aggregates. When both pressure and shear were applied to concrete, both the slump and viscosity decreased. As the rotational speed of the vane increased, changes in properties became significant. Shearing in the absence of pressure maintained the properties of concrete. However, shearing under pressure conditions caused a reduction in slump and viscosity.

Experimental Study of Check Valves in Pumping Systems with Air Entrainment

  • Lee, Thong-See;Low, Hong-Tong;Nguyen, Dinh-Tam;Rong, Wei;Neo, Avan
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.140-147
    • /
    • 2008
  • An experiment setup was introduced to study dynamic behaviour of different types of check valves and the effects of air entrainment on the check valve performance under pressure transient condition. The experiment results show that the check valves with low inertia, assisted by springs or small traveling distance/angle gave better performance under pressure transient condition than check valves without these features. Air entrainment was found to affect both wave speed and reverse velocity. With the increase of the initial air void fraction in pipeline, the experiment results show that the wave speed was reduced, the reverse velocity was increased. The first peak pressure increased initially and then decreased with the increase of the initial air void fraction, the pressure surge periods were increased proportionally with air void fraction due to the greatly reduced wave speed. The study can be applied to help choosing suitable check valves for a particular pumping system.

회전날개주위 분자천이유동에 관한 수치해석적 연구 (A numerical study on the molecular transition flow for the rotating blades)

  • 허중식;황영규;김동권
    • 대한기계학회논문집B
    • /
    • 제22권5호
    • /
    • pp.640-650
    • /
    • 1998
  • Pumping performances of a helical molecular drag dump(MDP) and of a radial MDPs are numerically analyzed by using the direct simulation Monte Carlo (DSMC) method. A helical- and radial-MDP have rotating pumping channels cut on a cylinder and on a disk, respectively. For a helical MDP, the present results agree quantitatively with the previously known numerical results. For radial MDPs, both of the Type 1 (having pumping channels cut on the stationary disk) and of the Type 2 (having pumping channels cut on the rotating disk) are analyzed to predict their performances for various parameters, i.e., the radius of curvature center of the channel wall, the depth of the channel, the clearance between housing and disk, and the rotating speed. The results show that the performance of the Type 2 is superior to that of the Type 1, and that for all types the pumping efficiency decreases as the clearance increases. Also, the radial type MDP has larger leakage losses in the direction of pumping channel than does the helical one.

벌집형 셀 구조를 가지는 스퍼터 이온펌프의 성능 분석 (Pumping speed of a sputter ion pump with a honeycomb anode cell structure)

  • 하태균;안병남;이득진;김진곤;정석민
    • 한국진공학회지
    • /
    • 제15권5호
    • /
    • pp.451-457
    • /
    • 2006
  • 벌집형 양극 셀 구조를 가지는 스퍼터 이온펌프를 제작하여 그 성능을 측정하고 기존의 원통형 구조와 비교하였다. 원통형 구조는 원통과 원통 사이에 기체의 이온화에 크게 기여하지 못하는 공간(dead space)이 전체의 10 % 정도 존재하는데, 벌집형 구조에서는 이러한 공간이 없으므로 이론적으로는 배기성능 또한 최대 10 % 정도 향상될 것으로 예측된다. 이러한 점에 착안하여 본 연구에서는 원통형 및 벌집형 셀 구조의 스퍼터 이온펌프를 제작하여 배기성능을 측정하여 서로 비교하였다. 그 결과 벌집형 구조가 원통형 구조에 비해 압력 구간에 따라서 $5%{\sim}11%$ 정도 배기속도가 높은 것으로 나타났다.

Optimization of the Material and Structure of Component Parts for Reducing the Number of Impurity Particles in CVD Process

  • Kim, Won Kyung;Woo, Ram;Roh, Jong Wook
    • 한국세라믹학회지
    • /
    • 제56권3호
    • /
    • pp.277-283
    • /
    • 2019
  • We have examined minimization of the number of impurity particles by replacing the load-lock chamber materials of the chemical vapor deposition equipment through optimization of the pumping method in the deposition chamber. In order to reduce the number of impurity particles in the chamber, the load-lock spacer material was changed from monomer casting nylon to Torlon. Furthermore, we controlled the pumping speed and number of pumping ports, which resulted in a reduction in the impurity particle generation from 2.67% to 0.52%. This study revealed that the selection of the material for the parts of a chemical vapor deposition chamber can minimize particle generation, thereby presenting a method of optimization method of the chemical vapor deposition chamber.