• 제목/요약/키워드: Pumping loss

검색결과 120건 처리시간 0.023초

분위기 조건 변화에 따른 저압 직접분사식 LPG의 점화성 및 연소특성 연구 (A Study on Ignition Probability and Combustion Characteristics of Low Pressure Direct Injection LPG according to a Function of Ambient Condition)

  • 정성식;황성일;염정국;전병열
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.32-42
    • /
    • 2016
  • Under part load condition of spark-ignition engine, pumping loss had great effect on engine efficiency. To reduce pumping loss, the study designed spark-ignited engines to make direct spray of gasoline to combustion chamber. In spark-ignited direct-injection engines, ignition probability is important for successful combustion and flame propagation characteristics are also different from pre-mixed combustion. This study designed a visualization testing device to study ignition probability of spark-ignited direct-injection LPG fuel and combustion flame characteristics. This visualization device consists of combustion chamber, fuel supply system, air supply system, electronic control system and data acquisition system. Ambient pressure, ambient temperature and ambient air flow velocity are important parameters on ignition probability of LPG-air mixture and flame propagation characteristics, and the study also found that sprayed LPG fuel can be directly ignited by spark-plug under proper ambient conditions. To all successful cases of ignition, the study recorded flame propagation image in digital method through ICCD camera and its flame propagation characteristics were analyzed.

CMOS 이미지 센서를 위한 고효율 Charge Pump (High-Efficiency Charge Pump for CMOS Image Sensor)

  • 김주하;전영현;공배선
    • 대한전자공학회논문지SD
    • /
    • 제45권5호
    • /
    • pp.50-57
    • /
    • 2008
  • 본 논문에서는 CMOS image sensor(CIS)에서 사용될 수 있는 고 효율 charge pump를 제안하였다. 제안된 charge pump는 CIS의 동작 특성을 활용하여 switching loss 및 reversion loss를 최소화하여 고 효율 동작을 실현하였다. 즉, CIS 픽셀 동작 구간에 따라 local clock driver, 펌핑 커패시터, 그리고 charge 전달 switch의 크기를 역동적으로 조절함으로써 switching loss 를 최소화하였다. 또한, schmitt trigger를 채용한 tri-state local clock driver를 이용하여 non-overlapping 구간이 충분히 확보된 local clock을 공급할 수 있게 함으로써 reversion loss를 최소화하였다. 0.13-um CMOS 공정을 이용한 시뮬레이션 비교 결과, 제안된 charge pump는 구동 전류가 없는 조건에서 기존 구조에 비해 최대 49.1% 전력 소모를 개선하였으며, 구동 전류가 최대인 조건에서는 19.0% 전력 소모를 개선할 수 있었음을 확인하였다.

충적층 양수정에서 우물개량을 통한 우물효율의 개선 (Improvement of Well Efficiency through Well Development in a Pumping Well)

  • 김규범;김병우;김성윤
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권1호
    • /
    • pp.39-49
    • /
    • 2010
  • Drilling at unconsolidated layer can make the aquifer disturbed and reduce a productivity of groundwater well. Surge block and air surging were applied to a pumping well located in Jeungsan-ri, Changnyung-gun, to improve a well efficiency by removing clogging and fine-grained slime. Two experimental log-linear equations, $y_1=-0.1769\;ln(x_1)+0.4960$ and $y_2=-84.3358\;ln(x_2)+512.8162$, were proposed in this site, in which $x_1$ and $x_2$ are the number of surging event, $y_1$ is the amount of slime, and $y_2$ is a recovery time of groundwater level after air surging. Well loss exponent (P) decreased after surging, from 3.422 to 1.439, and the groundwater inflow from aquifer happened in all directions around a well with gradually increasing the homogeneity in a local aquifer's hydraulic property. It was revealed that long-term well development should be done in the pumping well which is located in unconsolidated sediments to increase a well productivity.

저전력 DRAM 구현을 위한 boosted voltage generator에 관한 연구 (A study on the design of the boosted voltage cenerator for low power DRAM)

  • 이승훈;주종두;진상언;신홍재;곽계달
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.530-533
    • /
    • 1998
  • In this paper, a new scheme of a boosted voltage generator (BVG) is designed for low powr DRAM's. The designed BVG can supply stable $V_{pp}$ using a new circuit operting method. This method controls charge pumping capability by switching the supply voltage and ring oscillator frequency of driving circuit, so the BVG can save area and reduce the powr dissipation during $V_{pp}$ maintaining period. The charge pumping circuit of the BVG suffers no $V_{T}$ loss and is to be applicable to low-voltage DRAM's. $V_{pp}$ level detecting circuit can detect constant value of $V_{pp}$ against temperature variation. The level of $V_{pp}$ varies -0.55%~0.098% during its maintaining period. Charge pumping circuit can make $V_{pp}$ level up to 2.95V with $V_{cc}$ =1.5V. The degecting level of $V_{pp}$ level detecting circuit changes -0.34% ~ 0.01% as temperature varies from -20 to 80.deg. C. The powr dissipation during V.$_{pp}$ maintaining period is 4.1mW.W.1mW.

  • PDF

YBCO CC을 사용한 초전도전원장치의 요소특성 해석 (Characteristic analysis of components of a high temperature superconducting power supply using YBCO coated conductor)

  • 윤용수;조대호;박동근;양성은;김호민;정윤도;배덕권;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.40-45
    • /
    • 2009
  • Many superconductor applications such as MRI and SMES must be operated in persistent current mode to eliminate the electrical ohmic loss. This paper presents the characteristic analysis of the high temperature superconducting (HTS) power supply made of YBCO coated conductor (CC). In this research, we have manufactured the HTS power supply to charge the 0.73 mH HTS double-pancake magnet made of YBCO CC. Among the all design parameters, the heater triggerring time and magnet applying time were the most important factors for the best performance of the HTS power supply. In this paper, three-dimensional simulation through finite element method (FEM) was used to study the heat transfer in YBCO CC and the magnetic field of the magnetic circuit. Based upon these results, the final operational sequence could be determined to generate the pumping current. In the experiment, the maximum pumping current reached about 16 A.

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

짧은 못형핀의 형상 변화에 따른 열전달 및 마찰손실 특성 (Heat transfer and friction loss characteristics of shaped short pin-fin arrays)

  • 조형희
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.259-267
    • /
    • 1997
  • Average heat transfer coefficients and friction coefficients have been measured from staggered short pin-fin arrays to investigate the effect of fin shapes. Flow entering into the test section is a fully developed duct flow and the Reynolds number ranges from 5,000 to 25,000 based on fin diameter and average approaching velocity. The fin has three different shapes; uniform-diameter circular fin, two stepped-diameter circular fins. Average heat transfer rates change slightly with the fin shapes. However, friction loss(pressure loss) for the stepped-diameter fins is significantly less than that for the uniform-diameter fin. This results indicate that the stepped-diameter fin arrays in duct flow enhance heat transfer rates largely based on unit pumping power.

  • PDF

대형 수이젝터를 이용한 다목적댐 관개용수 펌핑시스템에 관한 연구 (A study on the irrigation water pumping system of multipurpose dams by the large water ejector)

  • 윤석훈;오철;손근홍;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.73-80
    • /
    • 1994
  • The water ejector is a low pressure high flow rate volumetric pump. It utilize the energy of a low mass flow, high velocity stream to induce a large mass flow, low velocity stream. In addition, it has a very good resistances to cavitation compared to the other type of pumps, and the maintenance cost is practically nil. There has been enormous energy loss to supply the upper part water of dam which has large potential energy as mere irrigation water in domestic multipurpose dam. The new type of energy saving system which developed through the present study can economizes over 950,000 kWh per year by mixing the upper part water of dam with the waste water by the large water ejector. This paper estimates the economical efficiency of the new type of irrigation water pumping system, and further more, represents the change of performance characteristics of large water ejector, which was adapted to this system, according to the fluctuation of upper water level that seasonally changes.

  • PDF

콘크리트 충전 강관 기둥의 시공에 관한 연구 (Mock-up Tests of Concrete Filled Steel Tubular Columns)

  • 이덕찬;최진만;이도헌;김훈;김진철;박연동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.382-387
    • /
    • 1996
  • Three concrete filled steel tubular columns with six inner diaphrams are constructed and tested under field conditions. The size and shape of three columns are exactly same. The cross section is $40\times40cm$, and the height is 9m. Each column is constructed with normal concrete, CFST concrete, and high flowing concrete, respectively. Concrete is pumped into bottom parts of steel tubular columns from a concrete pump on the ground. Test data indicate that the slump flow of the concrete place in the top of the column is lower than that of the concrete before pumping by about 10~20cm. Slump flow loss of high flowing concrete caused by pumping is high compared to the other concretes. Concrete pump pressure of high flowing concrete is somewhat higher than that of CFST concrete.

  • PDF

경천가뭄지역 농업용수 공급량의 수로손실 분석 (Analysis of Channel Water Loss of the Agricultural Water Supply in a Gyeongcheon Drought Area)

  • 조건호;문진경;최경숙
    • 한국농공학회논문집
    • /
    • 제62권2호
    • /
    • pp.53-62
    • /
    • 2020
  • The purpose of this study is to estimate the channel water loss of agricultural water supply in the command areas belong to Yechon irrigation channel of Gyeongcheon reservoir located Mungyeong-si, which area experienced a severe drought in 2015. The channel water loss was estimated by comparison of the irrigation water requirements (IWR) and agricultural water supply of the field data from 2012 to 2015. Further analysis was conducted to define the conveyance loss estimated based on the leakage holes and illegal pumping spots investigated through the field survey, and the distribution loss obtained by subtracting conveyance loss from the channel water loss. The annual rainfall decreased gradually, but the contribution of effective rainfall, available rain water to crop, increased to IWR during the study period. These phenomena resulted in the increase of agricultural water supply, and hence made greater the channel water loss simultaneously. The average channel water losses estimated as 36.8 % with 7.1 % of the conveyance loss and 29.7 % of distribution loss respectively. The distribution loss seems to be related to total number of rainy days, and irrigation schedules, while the conveyance loss was caused by irrigation channel aging conditions and illegal intake problems. In order to achieve sustainable agricultural water resources, the channel water loss needs to be reduced through the restoration of aged irrigation facilities and effective water managements in the fields.