• 제목/요약/키워드: Pumping Rate

검색결과 375건 처리시간 0.03초

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

Effect of Degradation Processes on Optimal Remediation Design Sorption and First-Order Decay Rate

  • Park, Dong-Kyu;Ko, Nak-Youl;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.503-508
    • /
    • 2004
  • Optimal remediation design using the pump and treat(P&T) method and natural attenuation was accomplished in consideration for degradation processes, such as sorption and first-order decay rate. Variation of both sorption and first-order decay rate has influence on design of optimal remediation application. When sorption effect increases, the more pumping rate and pumping wells are required. The location of operated wells is on the centerline of contaminant plume and wells near hot spot are mainly operated when sorption effect increases. The higher of first-order decay rate, the less pumping rate is required. These results show that the degradation processes have to be considered as one of the essential factors for optimal remediation design.

  • PDF

State of the Art on Prediction of Concrete Pumping

  • Kwon, Seung Hee;Jang, Kyong Pil;Kim, Jae Hong;Shah, Surendra P.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권sup3호
    • /
    • pp.75-85
    • /
    • 2016
  • Large scale constructions needs to estimate a possibility for pumping concrete. In this paper, the state of the art on prediction of concrete pumping including analytical and experimental works is presented. The existing methods to measure the rheological properties of slip layer (or called lubricating layer) are first introduced. Second, based on the rheological properties of slip layer and parent concrete, models to predict concrete pumping (flow rate, pumping pressure, and pumpable distance) are explained. Third, influencing factors on concrete pumping are discussed with the test results of various concrete mixes. Finally, future need for research on concrete pumping is suggested.

대평 양수장 지구의 농업용수회귀율 추정 (Estimation of Return Flow Rate of Irrigation Water in Daepyeong Pumping District)

  • 김태철;이호천;문종필
    • 한국농공학회논문집
    • /
    • 제52권1호
    • /
    • pp.41-49
    • /
    • 2010
  • Return flow rate of irrigation water was estimated by water balance method. Daepyeong pumping district to irrigate 75.8 ha of rice paddy in the Geum river basin was selected to install gauging instruments to collect data such as weather, water levels, infiltration rate and evapotranspiration during irrigation season (May 27 to Sept. 20) in 2003 and 2004. Irrigation and drainage discharge were calculated from the rating curve and evapotranspiration was estimated both by the modified Penman formula and by the lysimeter. The results were as followed : 1. Total amounts of pumping water during irrigation season were $1,076,000\;m^3$ in 2003 and $1,848,000\;m^3$ in 2004. Total amounts of rainfall were 1336.0mm and 1003.0mm respectively during the irrigation season in 2003 and 2004. 2. It was surveyed that the amount of infiltration was 196.5 mm (2.2 mm/day). The gauged evapotranspiration was 311.0 mm (3.5 mm/day) and the calculated evapotranspiration was 346.0 mm (3.9 mm/day) during irrigation period in 2003. It was surveyed that the amount of infiltration was 169.9 mm (2.4 mm/day). The amount of gauged evapotranspiration was 377.3 mm (5.3 mm/day) and the calculated evapotranspiration was 454.5 mm (6.6 mm/day) during irrigation period in 2004. 3. The rates of quick and delayed return flow were 52.4 % and 17.7 % respectively, and so return flow rate was 70.1 % in 2003. The rates of quick and delayed return flow were 45.4 % and 16.1 % respectively, and so return flow rate was 61.5 % in 2004. It means that average return flow rate in the Daepyeong pumping district was assumed to be 65 %.

Vacuum system design of a 10 ton/day class air liquefaction cold box for liquid air energy storage

  • Sehwan, In;Juwon, Kim;Junyoung, Park;Seong-Je, Park;Jiho, Park;Junseok, Ko;Hankil, Yeom;Hyobong, Kim;Sangyoon, Chu;Jongwoo, Kim;Yong-Ju, Hong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.65-70
    • /
    • 2022
  • A vacuum system is designed for thermal insulation of a 10 ton/day class air liquefaction cold box for liquid air energy storage. The vacuum system is composed of a turbomolecular pump, a backing pump and vacuum piping for the vacuum pumps. The turbomolecular pump is in combination with the backing pump for pumping capacity. The vacuum piping is designed with system installation conditions, such as distance from the cold box, connections to vacuum pumps and installation space. The capacity of the vacuum pump combination, namely pumping speed, is determined by analysis of the vacuum system, and pump-down time to 1×10-5 mbar is estimated. Vacuum piping conductance, system pumping speed and outgassing rate are calculated for the pump-down time with the ultimate pumping speed range of the vacuum pump combination of 1400 - 2300 l/s. Although the pump-down time gets shorter by larger capacity vacuum pumps, it mainly depends on target vacuum degree and outgassing rate in the cold box. The pump-down time is estimated as 3 - 6 hours appropriate for cold box operation for the pumping speed range. Considering the outgassing rate has uncertainty, the vacuum pump combination with pumping speed of 1900 l/s is chosen for the vacuum system, which is middle value of the pumping speed range.

Groundwater use management using existing wells to cope with drought

  • Amos, Agossou;Yang, Jeong-Seok
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.450-450
    • /
    • 2022
  • The study aims to develop scenarios for efficient groundwater use using existing wells in order to prepare for an eventual drought. In the recent decades, droughts are not only intensifying, but they are also spreading into territories where droughts used to be less intense and relatively infrequent. With the increasing disaster, efficient groundwater use is urgently needed not only to prevent the problem of groundwater depletion but also drought risk reduction. Thus, the research addressed the problem of efficient aquifer use as source of water during drought and emergencies. The research focused on well network system applied to Yanggok-ri in Korea using simulation models in visual MODFLOW. The approach consists to variate groundwater pumping rate in the most important wells used for irrigation across the study area and evaluate the pumping effect on water level fluctuation. From the evaluation, the pumping period, appropriate pumping rate of each well and the most vulnerable wells are determined for a better groundwater management. The project results divide the study area into two different regions (A and B), where the wells in the region A (western part of the region) show a crucial drop in water level from May to early July and in august as consequence of water pumping. While wells in region B are also showing a drawdown in groundwater level but relatively less compare to region A. The project suggests a scenarios of wells which should operate considering water demand, groundwater level depletion and daily pumping rate. Well Network System in relevant project, by pumping in another well where water is more abundant and keep the fixed storage in region A, is a measure to improve preparedness to reduce eventual disaster. The improving preparedness measure from the project, indicates its implication to better groundwater management.

  • PDF

초고층 압송계측을 통한 고성능 콘크리트의 유동특성과 압송성능과의 상관관계 (The Correlation between Rheological Properties and Pumpability of High Performance Concrete from High-Rise Pumping Monitoring)

  • 김규동;한천구
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.291-297
    • /
    • 2015
  • 본 연구에서는 초고층 구조물 시공에 사용되는 80MPa의 고성능 콘크리트를 대상으로 높이가 200m부터 350m인 지점까지 압송계측 결과를 근거로 하여 압송성능과 고성능 콘크리트의 유동특성과의 상관관계를 분석하였다. 굳지 않은 콘크리트의 물성과 초기강도 및 기준 재령에서의 압축강도 및 탄성계수는 모두 품질기준을 만족함이 확인되었다. 또한, 높이별 최대 압송압력은 약 10~15%씩 증가하였으며, 시간당 토출량은 최소 $25m^3$를 만족하는 것으로 나타났다. 또한, 압송압력과 마찰계수는 슬럼프 플로우의 크기에 반비례하는 것으로 나타났으며, 압송압력과 마찰계수는 T-500이 높을수록 증가하는 경향을 보였다.

유도침투량의 정량화를 위한 해석모형과 수치모형의 분석 (Analysis of Analytical Models and Numerical Model for Evaluating Induced Infiltration Rate)

  • 이도훈;이은태
    • 한국수자원학회논문집
    • /
    • 제32권3호
    • /
    • pp.301-310
    • /
    • 1999
  • 본 연구에서는 하천-대수층 계에서 수치모형과 두 종류의 해석모형을 적용하여 유도침투량 곡선을 유도하여 비교하였으며, 투수계수의 이방성비 및 지하수 유입 방향이 유도침투량 산정에 미치는 영향을 평가하였다. 유도침투량 곡선은 단순한 그래프 형태로 표시되며, 유도침투량, 양수량, 하천과 우물사이의 거리, 유동 지하수 유입량 등의 4가지 인자만을 포함하기 때문에 유도침투량의 결정에 유용하게 적용될 수 있다. 검토된 조건 아래에서 Wilson 해석모형과 FEWA 수치모형의 유도침투량 곡선은 근사적으로 일치하였으며, 투수게수의 이방성비는 유도침투량에 큰 영향을 미치는 인자로 평가되었다. 본 연구에서 적용된 방법과 도출된 결과들은 유도침투 현상을 이해하는데 도움이 되며, 양수우물의 계획 및 설계, 용수공급 우물의 수질관리에 필요한 유도침투량과 양수량의 최적 결정에 적용될 수 있다.

  • PDF

하천변 지하수 양수로 인한 하천수 감소 영향의 공간적 평가 - 죽산천 유역을 중심으로 - (Spatial Assessment of Effects of Near-Stream Groundwater Pumping on Streamflow Depletion)

  • 이정우;김남원;정일문;이민호
    • 한국수자원학회논문집
    • /
    • 제48권7호
    • /
    • pp.545-552
    • /
    • 2015
  • 본 연구에서는 죽산천 주변 지역에 대해 지하수 양수에 따른 하천수 감소 영향을 공간적으로 분석하였다. 하천 주변 500 m 이내에 위치한 지하수 관정 각각에 대해 지표수-지하수 결합모형 SWAT-MODFLOW를 이용하여 양수 후 하천수 감소량을 반복적으로 모의하였다. 모의 결과, 양수량 대비 하천수 감소율이 20~96%의 범위로 큰 차이를 보였으며, 특히, 하천과 관정간 이격거리가 100 m 이내, 수리확산 계수가 $500m^2/d$ 초과, 하천바닥층 수리전도성이 25 m/d를 초과한 경우에 양수량 대비 하천수 감소율이 60%를 넘어 양수 영향이 큰 것으로 분석되었다. 지하수 관정의 공간적인 위치에 따른 하천수 감소 영향을 정량적으로 쉽게 파악할 수 있도록 관정 위치별 하천수 감소량을 양수량 대비 퍼센트 값을 가지는 등치선 곡선으로 나타내었다. 죽산천 중하류구간 주변지역이 상류지역에 비해 지하수 양수로 인한 영향이 단기간에 크게 하천에 도달하였으며, 양수기간 5년 동안 평균적으로 약 66.7%의 하천수 감소율이 발생하는 것으로 분석되었다. 하천수량에 미치는 지하수 양수 영향을 공간적으로 표출함으로써 하천변 지하수 허가 관리에 있어 객관적인 정보로 활용할 수 있을 것이다.

지하수 유동 방향에 대한 관정배열이 분배추적자 시험에 미치는 영향 분석 (An Experimental Study of the Effect of the Test-well Arrangement on the Partitioning Interwell Tracer Test for the Estimation of the NAPL Saturation)

  • 김보아;김용철;여인욱;고경석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권3호
    • /
    • pp.111-122
    • /
    • 2014
  • Partitioning interwell tracer test (PITT) is a method to quantify and qualify a site contaminated with NAPLs (Non-Aqueous Phase Liquids). Analytical description of PITT assumes that the injection-pumping well pair is on the line of the ambient groundwater flow direction, but the test-well pair could frequently be off the line in a real field site, which could be an erroneous factor in analyzing PITT data. The purpose of this work is to study the influence of the angle of the test-well pair on the ambient groundwater flow direction based on the result from PITT. From the experiments, it was found that the obliqueness of the test-well pair to the ambient groundwater flow direction could affect the tracer test resulting in a decreased NAPL estimation efficiency. In case of an oblique arrangement of the test-well pair to the ambient flow direction, it was found that the injection of a chase fluid could enhance the estimation efficiency. An increase of the pumping rate could enhance the recovery rate but it cannot be said that a high pumping rate can increase the test efficiency because a high pumping rate cannot give partitioning tracers enough time to partition into NAPLs. The results have a implication that because the arrangement of the test-well pair is a controlling factor in performing and interpreting PITT in the field in addition to the known factors such as heterogeneity and the source zone architecture, flow direction should be seriously considered in arranging test-well pair.