• 제목/요약/키워드: Pumping Rate

검색결과 375건 처리시간 0.028초

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

지하댐 설치에 의한 수자원 개발량 평가 (Assessment of water resources by the construction of subsurface dam)

  • 김상준
    • 한국수자원학회논문집
    • /
    • 제50권11호
    • /
    • pp.795-802
    • /
    • 2017
  • 본 연구는 지하댐에 의한 수자원 개발량을 평가하는 방법론을 제시한다. 연구 대상지역으로 선택한 쌍천 지하댐은 동해안 쌍천유역 하구에 위치하며 비피압 충적 대수층을 형성하고 있다. 동해안에는 지형적으로 유사한 지하댐 후보지가 여러 개 존재한다. 본 연구에서는 대수층의 지하수위를 평면 2차원 FDM 모형으로 산출하였으며, 여기서 유역 유출은 대수층 표면에 침투항으로서 입력된다. 3개의 유역 유출모형의 평균으로서, 기저유량은 $0.5m^3/sec$로 산출되었다. 그리고 이 기저유량 근처의 유입량을 갈수기 유입으로 간주하여, 유입량 및 양수량 변화에 따른 지하수위를 산출하는 방법으로 수자원 개발량을 평가하였다. 구체적으로는 현재 속초시 생활용수를 공급하고 있는 실제 양수량($28,000m^3/day$)을 적용하여, 우물 수위가 대수층 바닥에 도달하거나 지하수위가 대수층 표면을 상회하여 지표수 흐름이 발생하는 유입량을 추정하였다. 또한 수자원 개발량을 증대시키기 위하여 우물의 양수량을 증가시키거나 추가 우물을 설치하는 상황을 재현하고, 극심한 갈수기에 가능한 양수량을 산출하였다.

Analysis of Pumping Characteristics of a Multistage Roots Pump

  • In, S.R.;Kang, S.P.
    • Applied Science and Convergence Technology
    • /
    • 제24권1호
    • /
    • pp.9-15
    • /
    • 2015
  • The practical pumping speed of a dry pump is considerably lower than the intrinsic speed because of back-streaming through finite gaps of the rotor assembly. The maximum compression ratio and the ultimate pressure of the pump are also directly influenced by the back-streaming rate. Therefore, information on the gap conductance, which determines the back-streaming characteristics of the rotor assembly, is the most important key for estimating the pumping performance of a dry pump. In this paper, the feasibility of calculating analytically the pumping performance of a multi-stage Roots pump, one of the most popular types of dry pumps, by quantifying the gap conductance in a rational way, is discussed.

비대칭 미세전극을 이용한 동시 혼합 및 펌핑 (Simultaneous mixing and pumping using asymmetric microelectrodes)

  • 김병재;윤상열;이경헌;성형진
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.77-83
    • /
    • 2007
  • This paper presents numerical and experimental works for simultaneous pumping and mixing small liquid using asymmetric microelectrode arrays, based on AC electroosmotic flows. To this end, four arrangements of electrode pairs were considered with diagonal/herringbone shapes. Numerical simulations were made of three-dimensional geometries by using the linear theory. The results indicated that the helical flow motions induced by the electrode arrays play a significant role in the mixing enhancement. The pumping performance was influenced by the slip velocity at the center region of the channel compared to that near the side walls. To validate the numerical predictions, the microfluidic devices were made through MEMS. The flow rate was obtained by using micro PIV, increasing the applied frequency. The electrolyte was potassium chloride solution. The flow patterns above electrodes were visualized to see lateral flow for mixing. The experimental results showed good agreements with the numerical predictions.

  • PDF

폐광 전후 삼탄 광산배수의 수질특성과 의의

  • 정영욱;강상수;임길재;홍성규;조원재;조영도;전호석;민정식
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.422-425
    • /
    • 2003
  • This study was carried out to apprehend the variation of quality of mine drainage in the abandoned Samtan coal mine. After closure of coal mine, although still pumping, water level in underground was raised to loom and the concentration of some elements such as Fe and Mn was elevated. At present, the worst pollution source in this area is too the acidic leachate drained from uncovered mine waste impoundment. The flow rate of mine drainage from the adit is ave. about 20,000t/d. If water were flooded and deteriorated due to stopping pumping, the impact of the mine drainage on the stream around the abandoned mine would be more severe. Therefore, It is considered that the prediction of water quality of mine drainage from the adit after stopping pumping will be very important with a view to establishing countermeasures.

  • PDF

양수장 용수공급 논 지대의 물수지 (Water Balance in a Paddy Field with Pumping Irrigation System)

  • 정운태;이근후;이인영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.1-7
    • /
    • 1998
  • To investigate the water balance in a paddy rice field with the pumping station for irrigation water supply, flow measurements and analysis on various components of water balance were carried out. The investigated area is 103.7 ha, and the irrigation water was supplied for 102 days during the total irrigation period starting from June 1. It was found that the consumption rate was increased as the growing stage was progressed. The variation of evapotranspiration rate was shown same tendency as the consumption rate, while no apparent tendency was found in infiltration rate upon different growing stages. And the ground water input to the area was predominant during the early stage of growing period, while ground water output from the study area was predominant at the end of the growing stage. The range of return flow rate, the ratio of total outflow to total inflow in every decad, was 57.6 to 85.7%. These values are slightly higher than reported values from the other investigation projects.

  • PDF

경북 고령군 강변여과 취수 지역의 지하수 유동 모사 및 민감도 분석 (Simulation of Groundwater Flow and Sensitivity Analysis for a Riverbank Filtration Site in Koryeong, Korea)

  • 원이정;구민호;김형수
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권2호
    • /
    • pp.45-55
    • /
    • 2006
  • 강변여과수 취수 방식의 도입이 고려되었던 경상북도 고령군 낙동강변의 충적대수층을 대상으로 2차원 지하수 유동모사를 수행하여, 취수정 및 주변 대수층에서의 지하수위와 하천수 유입량의 계절적 변화를 분석하였다. 개념모델의 하천 경계조건은 연평균 하천수위를 고정 수두로 설정하는 경우와 실제 관측된 시계열 자료를 이용하여 변동 수두로 설정하는 경우로 구분하여 모사를 수행하였다. 모사 결과 산정된 하천수 유입 비율은 고정하천수두 모사의 경우 연중 $74.3{\sim}87.0%$의 범위를 보이며 연평균 82.4%인 반면, 변동하천수두 모사의 경우 $52.7{\sim}98.1%$, 연평균 78.5%로 나타났다. 따라서 시기별로 변동하는 하천수위가 하천수 유입 비율에 큰 영향을 미치며, 하천수 유입 비율을 정확하게 산정하기 위해서는 변동하천수두 조건을 이용해야 하는 것으로 해석된다. 강변으로부터 취수정까지의 이격거리를 변화시키면서 모사를 반복 수행한 결과 취수정 이격거리가 커질수록 하천수 혼합 비율은 다소 감소하지만 그 영향이 수 % 정도로 매우 작게 나타났다. 강변여과 취수 시 지하수위 및 하천수 혼합비율에 영향을 미치는 인자인 대수층의 수리전도도 및 저유계수, 지하수 함양량, 취수량 등에 대한 민감도 분석을 수행하였다. 대수층의 평균 지하수위와 하천수 유입 비율은 취수량과 지하수 함양량 변화에 민감한 반면, 취수정의 지하수위는 수리전도도와 취수량에 민감한 것으로 나타났다.

전자냉동 김치독의 열유동 및 성능 특성 (Heat Flow and Cooling Performance of an Electronic Refrigerating Kimchi Jar)

  • 송규석;김경환;이승철;고철균;이재헌;오명도
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.928-936
    • /
    • 1999
  • The electronic refrigerating kimchi jar operates with a low noise because it contains no compressor but it consumes more energy than that of an refrigerator with compressor. In this paper, the heat flow characteristics and cooling performance of an electronic refrigerating kimchi jar are studied by means of experiments. When the storage temperature is kept in a range of $-5.7^{\circ}C$ to $4.1^{\circ}C$. in the case of three ambient temperatures; $12.7^{\circ}C$, $22.3^{\circ}C$ and $32.2^{\circ}C$, the cooling performance of $20{\ell}$ kimchi jar is investigated. The experiments show that the temperature difference that exists between kimchi jar and its ambient provides a measure of the coefficient of performance of kimchi jar. It is also found that ratio of net pumping heat to the heat pumping rate of thermoelectric module is independent of the temperature difference.

해안대수층에서 담수-염수 경계면 변화에 따른 최대담수양수량과 염수침투제어에 대한 실험적 연구 (Experimental Study of Freshwater Discharge and Saltwater Intrusion Control in Coastal Aquifer)

  • 서성국;오창무;김원일;호정석
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.159-168
    • /
    • 2010
  • 해안대수층의 지형특성과 수리특성에 의한 담수-염수 경계면과 최대담수양수량의 변화를 연구하였다. 모래 대수층의 수리전도도와 사면경사, 그리고 염수의 염도조건에 따른 담수-염수 경계면의 기울기 및 염수쐐기의 침투길이를 분석하였으며, 일정한 위치의 양수정에서 최대담수양수량과 염수침투제어를 위한 최적염수양수량을 실내 모래수조 모형을 이용하여 분석하였다. 실험결과, 대수층의 수리전도도가 높을수록, 사면경사가 급할수록 최대담수양수량은 증가되었으며, 이때 염도에 의한 영향은 상대적으로 미미하였다. 또한, 최대담수양수량이 증가함에 따라 염수침투제어를 위한 최적염수양수량이 비례적으로 증가되었으며, 그 양은 최대담수양수량 보다 평균 14% 증가되었다. 양수정의 위치에 따라 최대담수양수량과 최적염수양수량은 변화되었고, 염수위와 담수-염수 경계면에서 가까울수록 양수량은 감소하였다. 이러한 결과는 해안지역에서 지하수 개발량의 최대화를 위한 양수정의 위치 선정시, 대수층의 수리전도도, 사면경사 및 염도가 고려되어야 할 것으로 판단된다.

스탠딩컬럼웰(SCW)을 적용한 지열히트펌프의 성능에 대한 매개변수 연구 (A parametric study on the performance of heat pump using standing column well(SCW))

  • 장재훈;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.625-630
    • /
    • 2010
  • Parametric study was performed using the SCW numerical model for evaluating the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth well diameter, dip tube diameter, bleeding rate, were used in the study. Numerical simulations were performed for short-term (24-hour) simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

  • PDF