• Title/Summary/Keyword: Pumping Rate

Search Result 376, Processing Time 0.108 seconds

A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers (먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰)

  • Son, Doo Gie;Park, Seunghyuk;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.329-337
    • /
    • 2019
  • Bottled water companies in Korea are required to conduct an environmental impact assessment of their drinking water supply at least six months before the expiration of their five-year marketing and production license. The water level drawdown, production well water quality, and monitoring well observation results are the most important items that are evaluated in the assessment report. Here we evaluate the relationship between well drawdown and pumping capacity with pumping time from the production wells of bottled water manufacturers located in Cretaceous granite (site A) and Precambrian gneiss (site B). The method to reduce the pumping capacity is more effective in decreasing the drawdown than the method to simultaneously control the pumping and recovery times. Furthermore, the monitoring data from the pH monitoring sensors that were installed in Precambrian gneiss (site C) yield pH values that increase with time and eventually plateau at a certain value. We therefore propose that pH monitoring is either discontinued or improved to provide more reliable and usable results.

Numerical Analysis of the Flow Characteristics in the Nano Fountain-Pen Using Membrane Pumping (박막펌핑을 이용한 Nano Fountain-Pen의 유동 특성에 관한 수치적 연구)

  • Lee, J.H.;Lee, Y.K.;Lee, S.H.;Kim, Hun-Mo;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.2 s.35
    • /
    • pp.19-24
    • /
    • 2006
  • Nano fountain-pen is a novel device to make the constant patterning in micro process using new designed probe. Fountain-pen nanolithography (FPN) is applied for constant supply of liquid in conjunction of patterns and surface variation in the micro process. In this study, nuo fountain-pen is composed with reservoir, micro channels, tip and scondary chamber. Instead of traditional method only using capillary force, liquid can be definitely and exactly injected with membrane pumping by the repulse force of tip. It is dfficult to perform experiments in the micro range so that we carried out a numerical analysis for internal flow, using a commercial code, FlUENT, The velocity, pressure and flow rate are obtained under laminar, unsteady, three-dimensional incompressible flow with no-slip condition, and results are graphically described.

On the Flow and Pumping Characteristics of a Thermopneumatic Micropump with Electromagnetic Resistance for Electrically Conducting Fluids (전자기 저항을 이용한 열공압형 마이크로 펌프에서 통전유체의 유동 및 펌핑 특성에 관한 연구)

  • Oh, Se-Hong;Yong, Jung-Kwon;Kim, Chang-Nyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • An analysis has been conducted of the flow characteristics and pumping performance of a thermopneumatic micropump with electrically conducting fluid. In the present study, considered is a thermopneumatic micropump for electrically conducting fluids with electromagnetic resistance alternately exerted at the inlet and outlet by alternately applied magnetic fields. A model of Prescribed Deformation is used for the motion of the membrane. Here, the pumping performance of the micropump and flow characteristics of the electrically conducting fluid are investigated in the range of Hartmann number less than 30. The current numerical study shows that the net flow rate through the micropump is almost proportional to the strength of the applied magnetic field.

Estimation of Cardiac Pumping Performance according to the Ventricular Electrical Activation Time Distribution by Using Physiome Model (피지옴 모델을 이용한 심실의 전기활성시간 분포에 따른 심박출 성능평가)

  • Kim, Hyeong-Gyun;Lim, Ki Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.198-203
    • /
    • 2015
  • The purpose of the study is to examine the effects of pacemaker location on cardiac pumping efficacy theoretically. We used a three-dimensional finite element cardiac electromechanical model of canine ventricles with models of the circulatory system. Electrical activation time for normal sinus rhythm and artificial pacing in apex, left ventricular free wall, and right ventricular free wall were obtained from electrophysiological model. We applied the electrical activation time maps to the mechanical contraction model and obtained cardiac mechanical responses such as myocardial contractile ATP consumption, stroke work, stroke volume, ejection fraction, and etc. Among three artificial pacing methods, left ventricle pacing showed best performance in ventricular pumping efficacy.

A Study on the Break-down Characteristics of a Screw-type Centrifugal Pump due to Air Entrainment (공기흡입에 의한 스크류식 원심펌프의 양수불능 특성에 관한 연구)

  • Kim, You-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.58-63
    • /
    • 2003
  • The performance of turbo pump drops rapidly and it gets into break-down when the void fraction reaches above the threshold value because the impeller flow passage is choked up with air bubbles. Phenomenological understanding of break-down and pumping recovery mechanisms under air-water two-phase flow conditions are therefore important for pump designers and essential assignment for researchers. In this paper, we investigated the characteristics of break-down and pumping recovery due to entrained air occurring inside a screw-type centrifugal pump which has a wide flow passage mainly through the findings of suction and discharge pressures, rotational speed, flow rate measurements and visualization.

A Study on the Operating Characteristics of Variable Speed Pump for In-Line Booster Pumping Station (직결식 변속펌프의 운전 방안에 대한 연구)

  • Park, Jong-Moon;Choi, Sung-Il;Roh, Hyung-Woon;Suh, Sang-Ho;Kim, Sang-Gyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.191-196
    • /
    • 2001
  • In the systems with largely pipe head loss, variable speed pumps are generally used because substantial energy saving can be expected from such systems by controlling pump speed and also they offer simpler maintenance and operational ease even in conditions where abrupt changes In flow rate and head can occur. The invertor or the fluid coupling system are mainly adopted to control the rotating speed. In this paper, operating conditions at Migum pressing pump station(5 stage), where the fluid coupling system was the first installed for KOWACO, are investigated and analysed so that information thus gained can be usefully employed in the efficient operation of variable speed pump in new installations of in-line booster pumping station.

  • PDF

Study on Basic Performance Test of Electroosmotic Pump with Porous Glass Slit. (다공성 유리 슬릿 EO펌프 기초 성능 측정 연구)

  • Seo, Sang-Tae;Park, Cheol-Woo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.59-62
    • /
    • 2007
  • The basic concept and preliminary performance results of a miniaturized electroosmotic (EO) pump with diaphragms were included in the present study. The separation of an electroosmotic pumping liquid from a drug using diaphragms is mainly to have a freedom in choosing an electroosmotic pumping liquid and to achieve the optimal drug delivery, and, preferably its precise control. We performed maximum flow rate, maximum pressure, and maximum current measurements with and without diaphragm designs. As a result, the effect of diaphragms on pump performance at the maximum condition is small. However, the presence of diaphragms does not allow indefinite continuous pumping.

  • PDF

Effect of constraint severity in optimal design of groundwater remediation

  • Ko, Nak-Youl;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.217-221
    • /
    • 2003
  • Variation of decision variables for optimal remediation using the pump-and-treat method is examined to estimate the effect of the degree of concentration constraint. Simulation-optimization method using genetic algorithm is applied to minimize the total pumping volume. In total volume minimization strategy, the remediation time increases rapidly prior to significant increase in pumping rates. When the concentration constraint is set severer, the more wells are required and the well on the down-gradient direction from the plume hot-spot gives more efficient remediation performance than that on the hot-spot position. These results show that the more profitable strategy for remediation can be achieved by increasing the required remediation time than raising the pumping rate until the time reaches a certain limitation level. So, the remediation time has to be considered as one of the essential decision variables fer optimal remediation design.

  • PDF

INTENSITY VARIATION OF THE SiO MASER LINE OF LONG PERIOD VARIABLES : MASER PUMPING MECHANISM (장주기 변광성의 SiO 메이저 선 세기 변화 연구 : 메이저 펌핑 기작)

  • Kim, Eun-Hyeok;Lee, Sang-Gak
    • Publications of The Korean Astronomical Society
    • /
    • v.8 no.1
    • /
    • pp.83-104
    • /
    • 1993
  • In principle, both radiation and collision are capable of pumping the SiO masers. In order to check which pumping mechanism is more efficient, we calculated the rate equation for our model including the 3 vibrational slates with 7 rotational states of each vibrational slate. Through solving the radiative transfer equation with the Sovolev approximation, we estimated the line profiles from an expanding envelope for several transitions. It is found that the collision works more efficiently than the radiation for the inversion in excited vibrational stales. However in an expanding envelope model we could not get the strong line intensity as observed one because the population inversion is possible only in a small restricted region. For the enough population inversion to get type observed maser intensity. the number density of SiO and hydrogen molecules should be up to about $2{\times}10^5\;cm^{-3}$ and $1{\times}10^9\;cm^{-3}$, respectively, and the inversion should be occured in the region of no Jess than 11014cm.

  • PDF

Flow Rate Characteristics of Two Parallel Pumping System (두 대의 펌프가 병렬로 설치되는 계통에서의 유량 특성)

  • Park, Y.C.;Chi, D.Y.;Seo, K.W.;Yoon, H.G.;Park, J.G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.579-586
    • /
    • 2011
  • During a reactor normal operation, a primary coolant was designed to remove the fission reaction heat of the reactor. When one pump is failure and the other pump shall supply the cooling water to cool the reduced power, it is necessary to estimate how much flow will be supplied to cool the reactor. We carried a flow net work analysis for two parallel pumping system as based on the piping net work of the primary cooling system in HANARO. As result, it is estimated that the flow of one pump increased than the rated flow of the pump below the cavitation critical flow.

  • PDF