Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants (한국형 원자력발전소 펌프실 면적 산정 방안)

  • Lee, Hyo-Sung;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.36-41
    • /
    • 2013
  • For areas installed with one pump, the trend for expected sizes of pump room areas is observed once pump power and floor dimensions are provided. However, these pump rooms with auxiliary charging pumps, turbine driven auxiliary feedwater pumps, and pump rooms with a separate valve room have unique ways to determine the pump room area. No definite trends are identified for areas installed with two pumps using pump power and floor dimensions. The relationship between pump power and floor dimensions is also unable to be found.

  • PDF

Numerical Study of Turbine Blade Surface Gas Temperature with Various RPM and Blade Edge Shape (터빈 블레이드 회전수 변화와 터빈 블레이드 엣지 형상 변화에 따른 표면 가스온도 분포 해석)

  • Lee, In-Chul;Byun, Yong-Woo;Koo, Ja-Ye;Lee, Sang-Do;Kim, Kui-Soon;Moon, In-Sang;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.49-52
    • /
    • 2008
  • The numerical analysis for gas temperature of turbine blade surface has been performed to investigate development of temperature with various blade edge shape. Two different types of the turbine which one is "Sharp" edge and the other is "Round" edge was modeled. Computations have been carried out several turbine rotational speeds in the range from 0 to 10,000 rpm for the each types of turbine edge shape. As a result, the more rotational speed of turbine increased, the more turbine blade's temperature decreased. It is also found that the surface temperature of turbine blades for sharp type edge were lower than the round type edge.

  • PDF

A Numerical Study on the Automotive Torque Converter(Part I) - Hydraulic Design and Evaluation of Circulation Flow Rate - (자동차용 토크 컨버터의 수치해석적 연구(Part I) - 수력학적 설계와 순환유량의 평가 -)

  • 김홍식;박재인;주원구;조강래
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.28-36
    • /
    • 1998
  • In order to establish the hydraulic design process of the torque converter, pump, turbine and stator were designed by reverse design method including one dimensional analysis, angular momentum distribution and forced vortex design. And the significance of evaluation of the circulation flow rate in torus of the torque converter was verified by numerical calculation if the combined blade rows of pump and turbine. It was confirmed that the computational method using interrow mixing model by Park and Cho was reliable to predict the flow-field and performance of the torque converter.

  • PDF

Simulation of a geothermal power generation system using the Kalina cycle (칼리나 사이클을 이용한 지열발전 시스템의 시뮬레이션)

  • Chang, Ki-Chang;Baik, Young-Jin;Kim, Min-Sung;Lee, Young-Soo;Park, Seong-Ryong;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.626-629
    • /
    • 2008
  • In this study, a geothermal power generation system using the Kalina cycle was investigated by the simulation method. The Kalina cycle system can be used for the utilization of a low-temperature heat sources such as geothermal and industrial waste heat that are not hot enough to produce steam. The sea/river water can be considered as a cooling media. A steady-state simulation model was developed to analyze and optimize its performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump were modelled by an isentropic efficiency, while a condenser, an evaporator and a regenerative heat exchanger were modeled by UA-LMTD method with a counter-flow assumption. The effect of the ammonia fraction at the separator inlet on the cycle performance is investigated in detail.

  • PDF

Simulation of HFC organic Rankine cycles for geothermal power generation (지열발전을 위한 HFC 유기랭킨 사이클의 시뮬레이션)

  • Baik, Young-Jin;Kim, Min-sung;Chang, Ki-Chang;Yoon, Hyung-Kee;Lee, Young-Soo;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.569-572
    • /
    • 2009
  • In this study, HFC ORCs (Organic Rankine Cycles) are investigated for a low-temperature geothermal power generation by a simulation method. A steady-state simulation model is developed to analyze and optimize cycle's performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump are modelled by an isentropic efficiency. Simulations were carried out for the given heat source and sink inlet temperatures, and given flow rate that is based on the typical power plant thermal-capacitance-rate ratio. 3 HFC fluids are considered as a candidate for a working fluid of low-temperature ORCs. In this study, all optimized HFC ORCs are shown to yield almost the same performance in terms of power for a low-temperature heat source of about $100^{\circ}C$.

  • PDF

Development of a Starting Time Prediction Model for a Small Gas Turbine Engine (소형가스터빈엔진 시동시간 예측모델 개발)

  • Jun, Yong-Min;Choi, Jong-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.985-987
    • /
    • 2011
  • This paper includes a development of a starting time prediction model for a derivative engine. For this derivative engine design, a new map expansion method, Modified Pump Scaling Law(MPS), has been applied and expand the maps to sub-idle range. From loss characteristics of the reference engine, loss models for the derivative engine have been developed considering different pressure, temperature, and engine configurations. Starting time predictions of the derivative engine shows preferable results comparing test results.

  • PDF

A Study on the Development of Automatic Measuring System on the Alignment Offset of the Vertical Multistage Shaft (수직형 다단축의 축 정열 오프셋 자동 측정시스템 개발)

  • Park, H.C.;Kim, M.Y.;Lee, H.
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.922-928
    • /
    • 1998
  • This paper presents the automatic alignment measuring system for improving the accuracy and working time of alignment of large vertical hydraulic pump turbine. It is general practice that rotating shaft should run within acceptable vibration limit. In order to obtain better run-out data of multi-stage rotor, careful and accurate alignment approach must be established. Generally, present alignment procedure are required several iterative works and so many manpower. Therefore, the new system has been developed using a vector calculation algorithm, laser sensor and data acquisition devices. As a result of appling to actual machines, it is confirmed that manpower is saved up to an average 90%.

  • PDF

Sensitivity Analysis of Liquid Rocket Engine Performance (액체로켓엔진의 성능 민감도 해석)

  • Cho, Won-Kook;Nam, Chang-Ho;Park, Soon-Young;Kim, Chul-Woong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3159-3162
    • /
    • 2008
  • A sensitivity analysis of the liquid rocket engine has been made. A mode analysis program is used to predict the performance change due to the variation of rocket engine operating environment. The propellant supply pressure and density are the major variables of the operating condition. The material properties of the turbine driving gas is assumed as the function of mixture ratio. The discrepancies of performance change between constant turbine driving gas properties and variable properties are greater for the case of fuel pump inlet pressure change than the oxidizer pump inlet pressure change.

  • PDF

Multi-sensor data-based anomaly detection and diagnosis of a pumped storage hydropower plant

  • Sojin Shin;Cheolgyu Hyun;Seongpil Cho;Phill-Seung Lee
    • Structural Engineering and Mechanics
    • /
    • v.88 no.6
    • /
    • pp.569-581
    • /
    • 2023
  • This paper introduces a system to detect and diagnose anomalies in pumped storage hydropower plants. We collect data from various types of sensors, including those monitoring temperature, vibration, and power. The data are classified according to the operation modes (pump and turbine operation modes) and normalized to remove the influence of the external environment. To detect anomalies and diagnose their types, we adopt a multivariate normal distribution analysis by learning the distribution of the normal data. The feasibility of the proposed system is evaluated using actual monitoring data of a pumped storage hydropower plant. The proposed system can be used to implement condition monitoring systems for other plants through modifications.

Design of Hydrogen Peroxide Turbopump and Water Test (과산화수소 터보펌프 설계 및 수류시험)

  • Lee, Sung-Gu;Park, Dae-Jong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.317-320
    • /
    • 2011
  • Hydrogen peroxide turbopump was designed for bi-propellant liquid rocket engine using hydrogen peroxide and kerosene as propellants. Turbopump operation was verified through water tests. Design conditions of hydrogen peroxide turbopump were determined, and impeller was designed. Turbine which drives pump was selected from commercial turbocharger. Gas generator was designed by reference from turbine map. Pump, turbine, gas generator were integrated, and turbopump system was constructed. Turbopump supplied water by 1.47 bar of pressure and as well as 3.4 kg/s of mass flow rate.

  • PDF