• Title/Summary/Keyword: Pump system

Search Result 2,885, Processing Time 0.042 seconds

Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers (젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교)

  • Park, Chung-Saeng;Jo, Seong-Geun;Lee, Jeong-Gyu;Gang, Tae-Yeong;Park, Seong-Jae;Gong, Il-Geun;Choe, Min-Cheol
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.2
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF

Fuel cell system for SUAV using chemical hydride - I. Lightweight hydrogen generation and control system (화학수소화합물을 이용한 소형 무인항공기용 연료전지 시스템 연구 - I. 경량 수소 발생 및 제어 장치)

  • Hong, Ji-Seok;Jung, Won-Chul;Kim, Hyeon-Jin;Lee, Min-Jae;Jeong, Dae-Seong;Jeon, Chang-Soo;Sung, Hong-Gye;Shin, Seock-Jae;Nam, Suk-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A compact hydrogen generation device of fuel cell system using chemical hydride storage technique was designed to fit the propulsion device requirement of a small unmanned aerial vehicle(SUAV). For high efficient, compact, and lightweight hydrogen generation control device, the Co-B catalyst hydrogen conversion rate by $NaBH_4$ aqueous solution flux is measured so that the proper amount of Co-B catalyst for maximum hydrogen generation of 100W stack was proposed. A compact hydrogen generation device is controlled by pump's on/off using its own internal pressure and consumes fuel in high efficiency through a dead-end type fuel cell. The fuel cell system has stable operation for a planed flight profile. The system operates up to maximum 7 hours and at least 4 hours for tough flight profiles.

Atmosphere and Green Pepper Quality Influenced by Active Air Flushing in Fresh Produce Container Controlled in Real-time $O_2$ Concentration (실시간 $O_2$ 농도 제어 풋고추 용기에서 능동기체치환 시스템이 기체조성과 품질보존에 미치는 효과)

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.2
    • /
    • pp.29-33
    • /
    • 2014
  • Active air flushing mini-pumps were installed in a rigid polypropylene container ($32cm{\time}23cm{\time}18cm$) containing 900 g of fresh green peppers for effectively controlling its $O_2$ concentration on real time basis to preserve the product quality. The performance of the constructed system was compared to that of the modified atmosphere (MA) container system with gas diffusion tube controlled in close/open cycles responding to real time $O_2$ concentration at 10 and $20^{\circ}C$. In the control logic, the $O_2$ concentration was programmed to be located exactly at 13% or stay in the range of 13-15%. The active air flushing system could control the $O_2$ concentration in the desired level or range at both temperatures, while the passive diffusion system could work only under the low temperature condition of $10^{\circ}C$. At higher temperature of $20^{\circ}C$, the passive diffusion system could not manage the produce respiration increased more highly than the gas transfer through the diffusion tube, resulting in too low $O_2$ concentration and too high $CO_2$ concentration which would be injurious to the green pepper. When tested at $20^{\circ}C$, the MA container system could preserve the green pepper better than the perforated air package in terms of weight loss, ascorbic acid and chlorophyll contents and firmness.

  • PDF

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

A Study on Bilge Pumping Performance of 24,000TEU class Container Ship (24,000TEU급 컨테이너선박의 빌지 펌핑 성능에 대한 고찰)

  • Seo, Jang-Won;Yun, Jeong-In;Lee, Kyoung-Woo;Lee, Won-Ju;Park, Hoyong;Choe, Su-Jeong;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1100-1109
    • /
    • 2022
  • Herein, a case study was conducted on the bilge pumping performance of a 24,000TEU class container ship with an overall length of 400m. Although the bilge system of the 24,000TEU class container ship was designed in accordance with the rule requirements of the Classification Society, the bilge system did not satisfy the 2 m/s requirements of SOLAS Reg.II-1/35-1 under the rated flow rate and maximum flow rate conditions of the bilge pump installed in the ship. In particular, assumptions were made that No.1 ~ No.4 cargo holds were flooded and filled entirely by sea water and the evaluation of bilge pumping performance had been performed for No.1 ~ No.4 cargo holds. According to the evaulation results of the, the mean water velocity at the main bilge pipe for No.2, No.3, and No.4 cargo holds did not meet the 2 m/s criterion. To resolve this problem, in this study, the branch bilge pipe in each cargo hold was changed from 150A to 200A and the mean water velocity at the main bilge pipe for No.2, No.3, and No.4 was calculated as 2.479m/s, 2.476m/s, and 2.459m/s, respectively.

Multivessel Coronary Revascularization with Composite LITA-RA Y Graft (좌내흉동맥-요골동맥 복합이식편을 이용한 다중혈관 관상동맥우회술)

  • Lee Sub;Ko Mgo-Sung;Park Ki-Sung;Ryu Jae-Kean;Jang Jae-Suk;Kwon Oh-Choon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.359-365
    • /
    • 2006
  • Background: Arterial grafts have been used to achieve better long-term results for coronary revascularization. Bilateral internal thoracic artery (ITA) grafts have a better results, but it may be not used in some situations such as diabetes and chronic obstructive pulmonary disease (COPD). We evaluated the clinical and angiographic results of composite left internal thoracic artery-radial artery (LITA-RA) Y graft. Material and Method: Between April 2002 and September 2004, 119 patients were enrolled in composite Y graft for coronary bypass surgery. The mean age was $62.6{\pm}8.8$ years old and female was 34.5%. Preoperative cardiac risk factors were as follows: hypertension 43.7%, diabetes 33.6%, smoker 41.2%, and hyperlipidemia 22.7%, There were emergency operation (14), cardiogenic shock (6), left ventricle ejection fraction (LVEF) less than 40% (17), and 17 cases of left main disease. Coronary angiography was done in 35 patients before the hospital discharge. Result: The number of distal anastomoses was $3.1{\pm}0.91$ and three patients (2.52%) died during hospital stay. The off-pump coronary artery bypass (OPCAB) was applied to 79 patients (66.4%). The LITA was anastomosed to left anterior descending system except three cases which was to lateral wall. The radial Y grafts were anastomosed to diagonal branches (4), ramus intermedius (21), obtuse marginal branches (109), posterolateral branches (12), and posterior descending coronary artery (8). Postoperative coronary angiography in 35 patients showed excellent patency rates (LITA 100%, and RA 88.5%; 3 RA grafts which anastomosed to coronary arteries <70% stenosed showed string sign with competitive flow). Conclusion: The LITA-RA Y composite graft provided good early clinical and angiographic results in multivessel coronary revascularization. But it should be cautiously used in selected patients.

Control Algorithm Characteristic Study of Cooling System for Automotive Fuel Cell Application. (차량용 연료전지 냉각시스템 제어 알고리즘 특성 연구)

  • Han, Jae Young;Park, Ji Soo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • Thermal management of a fuel cell is important to satisfy the requirements of durability and efficiency under varying load conditions. In this study, a linear state feedback controller was designed to maintain the temperature within operating conditions. Due to the nonlinearity of automotive fuel cell system, the state feedback controller results in marginal stable under load condition from $0.5A/cm^2$ to $0.7A/cm^2$. A PWM (Pulse Width Modulation) and the modified state feedback controller are applied to control the temperature under the load condition from $0.5A/cm^2$ to $0.7A/cm^2$. The cooling system model is composed of a reservoir, radiator, bypass valve, fan, and a water pump. The performance of the control algorithm was evaluated in terms of the integral time weighted absolute error (ITAE). Additionally, MATLAB/SIMULINK$^{(R)}$ was used for the development of the system models and controllers. The modified state feedback controller was found to be more effective for controlling temperature than other algorithms when tested under low load conditions.

Culture of the Olive Flounder, Paralichthys olivaceus in a Marine Recirculating System (해수 순환 여과 사육 시스템에서 넙치 사육 시험)

  • Bang, Jong-Deuk;Choi, Yong-Suk;Seo, Hyung-Chul
    • Journal of fish pathology
    • /
    • v.18 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Bio-secure culture of olive flounder Paralichthys olivaceus in the IBK (Intensive Bioproduction Korean) recirculating system with dry pellet was tested for 6 months. The IBK system consists of 12 rearing tanks, 6 sedimentation tanks. 4-sectioned submerged biofilter chamber and channels. The size of each rearing tank was 3m in diameter and 1m in depth. The size of each biofilter chamber was $3.1\times3.3\times2.0$ m (D) and was filled with corrugated plastic plates as a biofilter medium. Total surface area of the biofilter was 3,789.7 $m^2$ Water was circulated by one of two vertical axial pump and circulating rate was about 34 times per day. A UV light sterilizer was used to treat inlet sea water with the flow rate of 4 ton/hr. All fish were treated with 150 ppm formalin 3 times with 5 day interval before stocking. It took 60 days for 'conditioning' the biofilter with the stocking density of 4.5 kg of fish $m^2$. The concentrations of ammonium-nitrogen, nitrite-nitrogen and nitrate-nitrogen in the system remained at the range of 0.096-0.315 mg/L, 0.015-0.504 mg/L, and 2.530-39.517 mg/L, respectively. Water temperature fluctuated from 17.5 to 25.1$^{\circ}C$ and salinity was from 30.1 to 33.5 ppt during rearing period. The fish grew from the average weight of 615.2 g to 1,201.1 g for 180 days. Initial and final fish densities were 8.4 and 15.9$kg/m^2$, Survival rate was 97.1 %. Neither parasites nor noticeable diseases was observed during the raring period even Vibrio spp. were detected from some fish in the system.