This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.
Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.
Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.
소형 무인항공기의 동력장치로 연료전지 시스템을 적용하기 위해 화학수소화합물 수소 저장방법을 이용한 소형 수소 발생 제어장치를 설계하였다. 효율이 높은 소형/경량 수소 발생 제어장치를 설계하기 위하여 $NaBH_4$ 수용액 공급 유량에 따른 Co-B 촉매의 수소 전환율을 확인하였고, 100W 스택의 최대 수소 발생량에 적합한 Co-B 촉매양을 제안하였다. 효율적인 연료 소모를 위해 Dead-end 방식의 스택을 선택하였고, 수소 발생 제어장치 내부 압력을 이용한 펌프 on/off 제어로 수소 생성량을 제어하였다. 소형 수소 발생 제어장치를 이용한 연료전지 시스템의 각 작동구간에서 안정된 운전을 확인하였다. 장시간 운전 실험을 통하여 최대 7시간 운전이 가능하며, 임의의 비행 프로화일에 요구되는 추력 프로화일은 최소 4시간 이상 조정 가능함을 확인하였다.
능동적 기체치환 소형 펌프를 900 g의 풋고추를 담은 폴리프로필렌 용기($32cm{\time}23cm{\time}18cm$)에 설치하여 품질보존에 도움이 되도록 실시간으로 $O_2$ 농도를 효율적으로 제어하고자 하였다. $10^{\circ}C$와 $20^{\circ}C$에서 제작된 능동기체치환 시스템과 실시간 $O_2$ 농도에 따라 튜브의 개폐가 제어되는 수동기체튜브 시스템을 수행효과 면에서 비교하였다. 제어 logic에서는 $O_2$ 농도가 바로 13%에 위치하거나 13~15%의 범위에 머물도록 프로그램되었다. $10^{\circ}C$에서는 두 시스템 모두가 요구된 적정 수준이나 범위의 $O_2$ 농도를 유지할 수 있었으나, 높은 $20^{\circ}C$의 온도에서는 수동기체튜브 시스템은 높은 풋고추의 호흡으로 인하여 과도하게 낮은 $O_2$ 농도와 허용범위 이상의 $CO_2$ 농도를 형성시켰다. 이에 반하여 능동기체치환 시스템은 높은 온도에서도 실시간 $O_2$ 농도에 즉각적으로 반응하여 적정수준이나 범위의 MA를 유지할 수 있었다. $20^{\circ}C$에서 능동기체치환 시스템으로 제어된 MA 용기는 통기성 대조구 포장에 비하여 5일 저장 후에 낮은 중량손실, 높은 ascorbic acid와 chlorophyll 함량과 경도 유지를 나타내어서 품질보존 효과가 우수하였다.
This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).
천연가스용으로 개조된 가스엔진에서 방출되는 폐열을 활용하기 위한 유기 랭킨사이클 (Organic Rankine Cycle: ORC) 발전시스템을 설계 및 제작하였다. 이 연구에서는 개조된 가스엔진의 폐열을 실험적으로 분석한 데이터를 바탕으로 구성한 ORC 시스템의 컴포넌트를 설계하고 제작하였다. ORC 시스템에는 2개의 판형 열교환기와 5kW급 팽창기, 다단 펌프가 사용되었으며, 전기 히터를 이용하여 ORC 시스템의 열역학적 성능을 분석하였다. 또한, 실제로 가스엔진과 연동하여 작동 특성을 파악하기 위한 실험을 수행하였다. ORC 시스템에 열량을 공급해주는 2대의 가스엔진을 사용하였다. 열원모사실험 결과, 열원온도 $110^{\circ}C$에서 축동력 5.22kW가 발생, 압력비 7.41, 열효율 9.09%가 계산되어졌으며, 엔진연동실험에서는 고온수 온도 $86^{\circ}C$에서 축동력 2kW가 발생, 이 때의 압력비는 3.75, 열효율 6.45%가 계산되었다.
가정 가사생활을 자동으로 관리 하는 Home Automation System은 점차 발전하고 있으며, 에너지의 절약과 재사용에 관한 부분 또한 점차 관심이 높아지고 있다. 일반 아파트에서 난방은 필수이다. 난방의 방법은 크게 두가지로 나눈다. 하나는 전기를 이용하는 것이고 다른 하나는 온수를 이용하는 것이다. 전기를 이용하면 전기요금의 상승으로 효률적이지 못하다. 그러나 온수를 이용하면 비용 면에서 많은 절감이 된다. 온수를 이용할 때, 온수의 온도가 모든 파이프에서 동일하지 못하다. 그러므로 실내의 온도를 설정치와 일치하지 못할때가 있다. 이러한 문제의 해결은 온수 파이프내에 온도 센서를 부착하여, 이 온도를 실시간으로 전송하고, 수신 측에서 온수의 온도를 조절하면 된다. 본 논문에서는 보일러 내부의 순환 pump가 난방수 순환에 따른 동력을 방바닥 시멘트 몰탈 내부의 소형교류 발전기에 의해서 전기에너지를 얻어 동작하는 저전력 기반의 난방배수관 자동온도 배수장치를 제안한다. 시스템의 전원은 프로펠러 수차 방식을 사용하여 분사수 충돌 방식을 사용하였으며, MCU 모듈은 atmel 사의 ATmega8, 통신모듈을 위하여 Chipcon사의 CC1020을 사용하였다.
본 연구에서는 전장이 400m인 24,000TEU급 컨테이너선박을 대상으로 선박 내 빌지펌핑의 성능에 대한 케이스 스터디를 수행하였다. 본 연구의 대상인 24,000TEU급 컨테이너선박의 빌지시스템의 경우 선급의 규칙에 맞게 설계되었지만, 선박 내 설치되어 있는 빌지펌프의 정격유량 및 최대유량 조건에서도 SOLAS Reg.II-1/35-1의 2 m/s 요건을 만족시키지 못하였다. 특히 1번 ~ 4번 화물창에 대해, 해수로 가득차 있다고 가정한 상태에서 해수를 모두 배출하는 동안에 빌지 주관에서의 평균유속을 계산할 결과, 2번 화물창, 3번 화물창 및 4번 화물창은 평균유속이 2 m/s 미만으로 기준에 적합하지 않은 것으로 나타났다. 본 연구에서는 이를 해결하기 위해 2번, 3번 및 4번 화물창의 150A 빌지 지관을 200A 배관으로 교체하여 계산을 수행하였으며, 그 결과 화물창 내의 해수를 모두 배출하는 동안의 빌지 주관에서의 해수평균유속이 각각 2.479m/s, 2.476,m/s 및 2.459m/s 로 기준을 만족시키는 것을 알 수 있었다.
배경: 동맥도관은 관상동맥우회술의 장기성적을 향상시키기 위해 사용되어 왔다. 양측 내유동맥 이식편은 좋은 결과를 보이나, 당뇨병과 만성폐쇄성폐질환 등에서는 그 사용이 제한적이다. 저자들은 다중혈관 관상동맥우회술에서 복합 좌내흉동맥-요골동맥 Y 이식편의 외과적 결과를 평가하였다. 대상 및 방법: 2002년4월부터 2004년 9월까지 복합 Y 이식을 시행한 119명의 환자를 대상으로 하였다. 평균 연령은 $62.6{\pm}8.8$세였으며, 여자는 34.5%였다. 수술 전 위험요소는 다음과 같다. 고혈압 43.7%, 당뇨병 33.6%, 흡연 41.2%, 고지질혈증 22.7%였다. 응급수술 14예, 심인성 쇼크 6예, 40% 이하의 좌심실 박출계수 17예, 좌주간 관동맥질환 17예였다. 퇴원 전 35예에서 관상동맥 조영술을 시행하였다. 결과: 평균 원위 문합수는 $3.1{\pm}0.91$개, 병원 사망률은 3예(2.52%)였다. 79예(66.4%)에서 인공심폐기를 사용하지 않은 관상동맥 우회술(off-pump coronary bypass grafting, OPCAB)을 시행하였다. 좌측 내흉동맥은 좌전하행지(l16개)와 대각지(9개)에 문합하였다. 요골동맥은 둔각변연지(109개), 중외관지(21개), 후하행지(45개), 후측방지(5개) 등에 문합하였고, 대복제 정맥은 후하행지(45개), 후측방지(12개), 대각지(17개), 둔각변연지(3개) 등에 문합하였다. 수술 후 시행한 관상동맥 조영에서 좌측 내흉동맥 100%, 요골동맥에서는 88.5%의 우수한 개통률을 보였다. 전례에서 내흉동맥-요골동맥 문합부위의 폐쇄나 협착은 없었으나 70% 미만의 협착을 보인 관상동맥에 문합한 3예의 요골동맥편에서 string sign이 나타났다. 결론: 좌내흉동맥-요골동맥 Y 복합이식은 다중혈관 관상동맥우회술에서 우수한 조기 임상 및 혈관조영 결과를 확인할 수 있었으며 선택적으로 시행할 수 있다.후 유리혈장색소는 $T-PLS^{TM}$군에서 유의하게 낮게 측정되었다$(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;vs\;46.8{\pm}23.0\;in\;Bio-pump^{TM},\;p<0.05)$. 수술 후 심근경색, 부정맥, 신부전, 뇌혈관질환 이환율은 두 군에서 차이가 없었다. 수술 후 사망은 $T-PLS^{TM}$군에서 1예(5%) 발생하였으나 통계적 유의성은 없었다. 결론: 박동성 혈류펌프인 $T-PLS^{TM}$를 이용하여 심폐기하 관상동맥 우회술을 시행하였다. 수술 중 기계오류에 의한 사고는 없었고 수술 후 임상경과가 $Bio-pump^{TM}$를 이용하여 수술한 경우와 차이가 없었다. 또한 박동성 혈류의 문제점이었던 혈구손상은 감소하였다. 저자들은 본 연구를 통해 $T-PLS^{TM}$의 안정성을 확인하였다.. 경우에는 8-aza-bicyclo[3,2,1]octan-3-one ring들의 steric hindrance의 영향에 의해 1,3-di-8-aza-bicyclo[3,2,1]octan-3-onyl)benzene은 합성되지 않았다.료된다. 또한 본 연구를 통해 도출된 선택속성 차원 중 많은 경우에 있어 고객이 인지하고 있는 중요도에 비해 수행도가 낮은 것으로 나타나 해당 차원의 개선을 위한 경영자들의 노력이 요구되어 진다. 체중군(0.82)에 비해 영양 질적 지수(INQ)가 높았으며(p<0.0335), 비타민 $B_1$은 정상 체중군이 유의적으로 가장 높은 영양 질적 지수를 보여주었다(p<0.0452). 이상의 결과로 볼 때 대학생들은 과체중보다는 저체중의 비율이 높았으므로 적정 체중 유지와 더불어 잘못된 식습관과 식이 섭취를 하고 있었다. 이에 대한 인식과 이를 교정할 수 있는 영양 교육이나 이를 토대로 한 세대를 짊어질 대학생들의 영양
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.