Numerical Simulation in the IC Engine Lubricating Gerotor Oil Pump (엔진 윤활용 제로터 오일펌프 유동해석)

  • Jo Sok-Hyun;Park Jae-In;Nam Kyung-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.1019-1025
    • /
    • 2006
  • Numerical simulations were conducted on the gerotor type oil pump. Three oil pump models having different port and groove shape were considered. Firstly, two original models (baseline & variant.1 model) were simulated in order to validate the accuracy of the simulation results and to better understand the flow characteristics in the pump. It was found that the cavitation phenomenon as well as the teeth tip leakage is most important parameter on the pump performance. Based on the simulation results of the original models, final model (variant.2 model) which has improved port shape and pressure relief valve is suggested to enhance pump performance and to reduce driving torque. The volumetric efficiency and the hydraulic torque of the Variant.2 model is improved 4% and reduced 6.1% each at 2000RPM in experiment.

A Soft Actuation System with Origami Pump for Maximizing Haptic Feedback (햅틱 피드백 극대화를 위한 오리가미 펌프 기반의 소프트 구동기 시스템)

  • Jung, Pyeong-Gook;Jang, Hyukjoon;Cha, Youngsu
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Traditional actuation system such as electric and pneumatic actuator has obvious advantages and disadvantages. To combine advantages and compensate disadvantages of the traditional actuation, a pneumatic actuation system with an internal air pressure source is noteworthy approach. In this paper, a soft pneumatic actuation system based on origami pump is described for haptic feedback glove. To improve wearability, an origami pump is introduced because the origami pump is much lighter than air compressor. The miniaturized electric actuation system is also designed with 3D printed planetary gear in order to reduce the volume of the system. To figure out the performance of the system, shrinkage distance of origami pump was measured with vision camera. The pressure in the origami pump was also estimated to understand the performance of the system.

Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted (태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구)

  • Lee, Jin-Kook;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

Hydraulic Performance Test of a Turbopump (터보펌프의 수력 성능시험)

  • Hong Soon-Sam;Kim Dae-Jin;Kim Jin-Sun;Choi Chang-Ho;Kim Jinhan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.243-247
    • /
    • 2005
  • Hydraulic performance test was conducted for a fuel pump of a liquid rocket engine turbopump. The pump driven by an electric motor was tested in water environment. It is experimentally shown that the inducer had very small effect on the pimp's head and efficiency but great effect on the pump's cavitation performance. Additionally, inducer test was carried out to investigate the effect of the inducer on the pump in detail, and it was found that the pump had a critical cavitation number when the inducer head dropped by $55\%$.

  • PDF

Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant (R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성)

  • Choi, Youn Sung;Kang, Hee Jeong;Kim, Eun Oh
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea (히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석)

  • Kang, Shin-Hyung;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.

A Study on the Performance and Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump (극저비속도 원심펌프의 성능과 내부유동특성에 관한 연구)

  • Kurokawa Junichi;Lee Young-Ho;Choi Young-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.784-794
    • /
    • 2005
  • In the very low specific speed range ($n_s=0.24$ < 0.25, non-dimensional), the efficiency of centrifugal pump designed by a conventional method is very low in common. Therefore, positive-displacement pumps have long been used widely. Recently, since the centrifugal pumps are becoming higher in rotational speed and smaller in size, there expects to develop a new centrifugal pump with a high performance to replace the positive-displacement pumps. The purpose of this study is to investigate the internal flow characteristics of a very low specific speed centrifugal pump and to examine the effect of internal flow pattern on pump performance. The results show that the theoretical head definition of semi-open impeller should be revised by the consideration of high slip factor in the semi-open impeller, and the leakage flow through the tip clearance results in a large effect on the impeller internal flow. Strong reverse flow at the outlet of semi-open impeller reduces the absolute tangential velocity considerably, and the decreased absolute tangential velocity increasese the slip factor with the reduction of theoretical head.

The Performance of Capacity Modulation and MIMO Control for System Heat Pump (시스템 히트펌프의 용량조절 및 다변수 제어 특성에 관한 연구)

  • Song, In-Sik;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.364-369
    • /
    • 2007
  • A system heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the system heat pump has been employed in small and medium-sized buildings. However, the performance data and control algorithm for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of a system heat pump with two indoor unit is measured by varying indoor loads, EEV opening, and compressor speed. In addition, the integral optimum regulator which includes MIMO control algorithm is proposed. The capacity modulation and optimum capacity for each indoor unit can be adjusted by utilizing the EEVs opening and compressor speed. The proposed scheme shows appropriate control performance at test conditions.

  • PDF

Experimental Verification of Spur Gear Pump based on FEM Analysis (FEM해석 기반 스퍼기어 펌프의 실험적 검증에 대한 연구)

  • Lee, Chan-Woo;Kim, Sang-Yu;Lee, Seo-Han;Kim, Jae-Yeol;Lim, Jin-Hyuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2022
  • This work investigated the performance improvement of a medium-pressure fixed-displacement-type SPUR gear pump, which is mainly used in the machine tool industry. The 3D CFX analysis and IS technique were applied using ANSYS (commercial FEM code) and compared with experimental results to ensure the reliability of the analysis. In addition, the performance improvement of the pump was obtained using the theoretical volumetric displacement equation, and the gear tooth width was changed. The pressure flow performance curves were compared, and the results were analyzed according to the width of the gear teeth. This is a factor that can cause irregular flow, vibration, and noise inside the gear pump owing to friction between the housing and gear pump.

Performance Prediction of Model Mixed Flow Pump Using Similarity (상사성을 이용한 model 사류펌프의 성능 예측)

  • Lee, Duck-Hyong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.393-400
    • /
    • 2005
  • As one of the useful and powerful methods for designing the optimum pump is using model pump, it is based on the similarity characteristics of turbomachinery. With this theory, we can predict the performance of various pumps. In fact we have performed huge pumps using this, the experimental results were to be sufficient to prove the similarity characteristics. In this study, we predicted the performance of the huge proto-type pump that cannot be installed and made a test. First of all, we had calculated the model ratio between proto-type and model. There were two ways to estimate the performance. One was the application of CFD code, and the other way was model field test. So We selected both of them to guarantee the dependable data and evaluated each other.

  • PDF