• Title/Summary/Keyword: Pump Monitoring

Search Result 190, Processing Time 0.026 seconds

A Pump with Improved Liner Ring and It's Monitoring System (라이너 링을 개선한 펌프 및 그 모니터링 시스템)

  • Choi, Yong-wom;Choi, Yeon-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.697-700
    • /
    • 2021
  • In this paper, a study was conducted on a technology that can improve and maintation the performance of a pump by using carbon composite liner ring for pump. The bigges weakness of mechanical deviced in rotational motion is vibration. We developed monitoring system on vibration, it will give convernience and conducted to user's 'pump with improved liner ring and monitoring system' is confirmed that pump's efficiecny performance is excellent to existing pump and maintenance.

  • PDF

Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system (지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화)

  • Shim, Byoung-Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF

Monitoring System of The Infusion Pump (인퓨전 펌프 모니터링 시스템 개발에 관한 연구)

  • Park, JunBeom;Koo, BonJae;Lee, WuJu;Lee, SangBin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.129-132
    • /
    • 2016
  • The importance of the infusion pump monitoring system has become amplified in accordance with the growth of IoT(Internet of Things) technology and medical devices. A monitoring system can be described as an essential part of infusion pump system because the patient must be observed all the time. Infusion pump monitoring system is significant to have better safety and efficiency. In this paper, we propose an efficient algorithm and scheme in the infusion monitoring system. In particular, the proposed algorithm based on the time of the database interlocking part was found to have a 30% higher efficiency than the conventional method.

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

Design and Implementation of Multi-monitoring System for Motor Pump (모터 펌프를 위한 멀티-모니터링 시스템 설계 및 구현)

  • Kim, Tae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.81-86
    • /
    • 2019
  • According to the needs of many users, motor pumps have been steadily developed and widely used in many industries where fluids are used. Motor pumps are used in a variety of environments, degrading quality and performance. It is becoming important to monitor the condition of motor pumps in order to maintain system performance and increase efficiency. This paper presents the method for effectively monitoring the condition of motor pumps. The designed MMI controller receives the collected data through data logging and output and controls the motor pump with touch screen. Implementing a Wi-Fi monitoring system and SCADA monitoring system based on Ethernet and RS485, user can monitor even if the user is far from the MMI controller without time and space limitation. In addition, by implementing a voice output system, the user can immediately recognize the situation through the sound. Therefore, through the proposed method, multi-monitoring system solves the cause of breakdowns and degradation of motor-pump and gives the possibility of commercialization by providing the convenience of maintenance to users.

Design of Remote Infusion Pump Monitoring System Using Wireless Network and RFID Technology (무선 네트워크와 RFID 기술을 이용한 원격 Infusion Pump 모니터링 시스템 설계)

  • Lee, Seo-Joon;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.159-167
    • /
    • 2013
  • Development of infusion pumps enabled injecting medical substances continuously and automatically to patients in hospitals. However, in cases when patients encountered emergent situations when moving to other areas, no clear measures were taken. The problem is that even the lightest error in injecting medical substances could be critical to the patient. That is why we proposes a remote infusion monitoring system using wireless network and RFID technology in this paper. When a problem occurs in the infusion pump, the medical personnel are informed of their patients' emergent situation and location information via wireless network so not only can they swiftly and accurately provide medical services but also can prevent safety accidents due to infusion pumps.

A Study on the Effectiveness of Flammable Gas Monitoring System in the Cargo Pump Room of Tanker

  • Kim, Mann-Eung;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.455-460
    • /
    • 2008
  • The flammable gas monitoring system is to be provided in cargo pump rooms of tankers in accordance with the requirements of SOLAS regulations, and flammable gas detectors are to be arranged in a proper position. In this paper, simulation tests and CFD analysis are carried out under the actual ventilation conditions of pump rooms in the ship in service. Based on the results, a new guidelines for an arrangement of flammable gas detectors are suggested.

Impact test of a centrifugal pump used in nuclear power plant under aircraft crash scenario

  • Huang, Tao;Chen, Mengmeng;Li, Zhongcheng;Dong, Zhanfa;Zhang, Tiejian;Zhou, Zhiguang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1858-1868
    • /
    • 2021
  • Resisting an accidental impact of large commercial aircrafts is an important aspect of advanced nuclear power plant (NPP) design. Especially after the 9·11 event, some regulations were enacted, which required the design of NPPs should consider the accidental impact of large commercial aircrafts. Normal working of equipment is important for stopping reactor under an impact when an NPP is in operation. However, there is a lack of reliable analysis and research on the impact test of nuclear prototype equipment. Therefore, in order to study the response of the equipment under high acceleration impact, a centrifugal pump is selected as the research object to perform the impact test. A horizontal half-sinusoidal pulse wave was applied to the working pump. The test results show that the horizontal response of the motor and flange is greater compared to other parts, as well as the vertical response of the coupling. The stress response of the pump body support and motor support is high, hence these parts should be considered in the design of the pump. Finally, combined with the damage and stress evaluation results of the pump under different amplitudes, the ultimate impact acceleration that the pump can withstand is given.

Evaluation of Thermodynamic Method for Pump Performance Measurement (열역학적 방법을 이용한 펌프 운전성능 평가법 검토)

  • Kang, Shin-Hyoung;Kim, Jin-Kwon;Hong, Soon-Sam;Yates, Alex
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.3 s.8
    • /
    • pp.25-30
    • /
    • 2000
  • Thermodynamic method of pump performance measurement calculates pump efficiency and flowrate by measuring fluid temperature increase and pressure rise through the pump. The theory of this method is investigated and precise comparison experiment with classical hydraulic method was conducted to verify the accuracy. Classical hydraulic pump performance measurement results and Yatesmeter results based on the thermodynamic method showed good agreement in measured performance.

  • PDF

Installation and Monitoring of Bankfiltration (including alluvial and riverbed deposits) Source Heat Pump Cooling System (강변여과수(충적층 및 하상)를 이용한 냉방시스템 설치 및 모니터링)

  • Jung, Woo-Sung;Hwang, Ki-Sup;Ahn, Young-Sub
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.5-8
    • /
    • 2006
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, pilot test facility for using the geothermal energy source from riverbank filtration was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connect ing a heat pump system into the exist ing pumping well in Changwon riverbank filtration site. One set of monitoring results during summer was presented and analyzed.

  • PDF