• 제목/요약/키워드: Pulsing pressure

검색결과 21건 처리시간 0.033초

연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측 (A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance)

  • 손정삼;서정민;박정호
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측 (Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance)

  • 손정삼;정용현;서정민
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

RF pulsing이 Ionized Magnetron Sputtering의 이온화율 향상에 미치는 효과 (Effects of RF Pulsing on the Ionization Enhancement in Ionized Magnetron Sputtering)

    • 한국진공학회지
    • /
    • 제7권3호
    • /
    • pp.255-260
    • /
    • 1998
  • Ionized magnetron sputtering은 high density plasma를 사용하여 스퍼터된 입자의 이온화율을 기판에서의 플럭스 기준으로 80%이상까지 증대시킬 수 있는 방법으로 반도체 소자의 아주 작은 홀이나 via contact등을 채울 수 있는 아주 유용한 수단이나 가스의 압력 이 30mTorr 이상으로 상당히 높아야만 이온화율이 높게 유지되어 스퍼터 증착 속도가 느려 지고 중성입자의 각도 분포가 넓어지는 단점이 있다. 그 원인이 스퍼터된 입자들에 의한 전 자 온도의 급격한 감소와 타겟 주변에서의 가스 희귀화 현상에 있다고 보고 이를 보완하고 자 스퍼터 전력을 펄스화 하는 방법을 고안하여 실험하였다. 그 결과 펄스의 on/off time이 10ms/10ms, 100ms/100ms에서 가장 높은 이온화율을 가시광 분광 결과에서 보였으며 실제 로 Ag의 XRD결과 (111)에서 (200)으로 우선 방위의 현격한 변화가 관찰되었다. 이를 고전 력 스퍼터링에 의한 중성 가스 가열과 냉각의 측면에서 해석하였다.

  • PDF

FIV 시험루프의 유동기인 진동 신호분석 (Flow-Induced Vibration Signal Analysis of the FIV Test Loop)

  • 이강희;강흥석;윤경호;송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF

개량된 PWM 알고리즘을 이용한 공압 레귤레이터의 압력제어에 관한 연구 (A Study on Pressure Control of Pneumatic Regulator using Modified PWM Algorithm)

  • 김형석;안경관;이병룡;윤소남
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.64-70
    • /
    • 2005
  • The development of an accurate and energy saving pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation(MPWM) valve pulsing algorithm allows the pneumatic regulator to become energy saying system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM(MPWM) algorithm shows that control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm are demonstrated through experiments with various reference trajectories.

접촉계면 반사 초음파의 음향 비선형 특성 (Acoustic Nonlinear Characteristics of Ultrasonic Wave Reflected at Contact Interfaces)

  • 박병준;이태훈;김정석;장경영
    • 비파괴검사학회지
    • /
    • 제31권1호
    • /
    • pp.40-46
    • /
    • 2011
  • 닫힘균열과 같은 고체-고체의 접촉계면에서 접촉 음향 비선형성을 평가하기 위해 벌크 투과파를 이용하는 기존의 전통적인 음향 비선형 기술의 경우 현장 적용하는데 있어서 송수신 탐촉자를 장착하기 위해 구조물 내부로 접근하는 것은 접근한계성의 어려움이 있다. 본 연구에서, 고체-고체의 접촉계면에서 음향 비선형성을 측정하기 위해 새로운 반사기법을 제안하였고 이는 대상재료의 동일한 면에서 송신과 수신을 하여 현장 적용성에 매우 편리한 기법이다. 이를 위해, 접촉압력에 대한 멱함수 모델를 통한 선형 그리고 비선형 강성을 추정하고 이를 기반으로 계면에서 반사된 초음파의 비선형 파라미터를 이론적으로 계산하였다. A16061-T6 시편에 대한 접촉압력에 따른 접촉계면 실험 결과들은 이론적인 예측과 매우 잘 일치하였으며 따라서 본 연구에서 제안된 반사모드 기술의 유효성을 검증하였다.

A Study on Energy Saving Algorithm of Electro-Pneumatic Regulator with Modified PWM Driven Method

  • Kim, Hyoung-Seok;Ahn, Kyoung-Kwan;Lee, Byung-Ryong;Yun, So-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1339-1345
    • /
    • 2006
  • The development of an accurate and energy saving electro-pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation (MPWM) valve pulsing algorithm allows the electro-pneumatic regulator to become energy saving system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM (MPWM) algorithm shows that the control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm is demonstrated through experiments with various reference trajectories.

A Study on Energy Saving Algorithm of Pneumatic Regulator with Modified PWM Driven Method

  • Kim, H.S.;Ahn, K.K.;Lee, B.R.;Yun, S.N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1339-1342
    • /
    • 2005
  • The development of an accurate and energy saving pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation(MPWM) valve pulsing algorithm allows the pneumatic regulator to become energy saving system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM(MPWM) algorithm shows that the control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm is demonstrated through experiments with various reference trajectories.

  • PDF

수직 지진 진동에 의해 유발된 해진에 대한 관내토의 거동 (Response of Soil Plug to Seaquake Induced by the Vertical Seismic Excitation)

  • 최용규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.81-88
    • /
    • 1998
  • During an earthquake, there are three main components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation induced by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the soil plugs in open-ended pipe piles installed at offshore sites. In this study, seaquake excitation induced by the vertical ground shaking was simulated by pulsing the water pressure at the seabed. During a seaquake, due to induced excess porewater pressure and pressure gradients in the soil, the capacity of open-ended pipe piles installed in a simulated sea depth of greater than 220 m was reduced serevely and the soil plugging resistance was degraded by more than 80%. The soil plug was failed because of the upward seepage forces that developed in the soil plug due to excess pore water pressure produced in the bottom of the soil plug during the seaquake. The compressive capacity of an open-ended pile in a simulated sea depth of less than 220m was reduced only by about 10%, and the soil plug resistance was degraded by less than 5%.s than 5%.

  • PDF