• Title/Summary/Keyword: Pulser

Search Result 45, Processing Time 0.02 seconds

Influence of Ultrasonic Waves on the Stacking Orientation in Carbon Fiber/Epoxy Composite Laminates

  • Park, Je-Woong;Kim, Do-Jung;Hsu, David K.;Seo, Young-Hwan;Im, Kwang-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.8-13
    • /
    • 2008
  • In this study, an investigation of shear wave ultrasonic technique was carried out to detect stacking orientation error for CF/Epoxy quasi-isotropy composite laminates. The ultrasonic shear wave is particularly sensitive to ply orientation and layup sequence in tire CF/Epoxy composite laminates. In the manufacturing of composite laminates, it is important that layup errors be detected in samples. In this work, an effect was mack to develop shear wave techniques that can be applied to composite laminates. During testing, the mast significant problem is that the couplant conditions do not remain the same because of its changing viscosity. The design and use of a shear ware transducer would greatly alleviate the couplant problem. A pyramid of aluminum, with isosceles triangle (two 45o angles) sides, was made to generate shear waves, using two longitudinal transducers based on an ultrasonic-polarized mechanism. A signal splitter was connected to the pulser jack on a pulser/receiver and to the longitudinal transducers. The longitudinal transducers were mounted with mineral oil, and the shear transducer was mounted with burnt honey on the bottom as a receiver. The shear wave was generated at a maximum and a minimum based on the ultrasonic-polarized mechanism. Results show it is feasible to measure layup error using shear wave transducers on a stacking of prepregs in composites.

Marine Seismic Survey using a Multi-source System (다중음원 시스템을 이용한 해양 탄성파 탐사)

  • Kim, Hyun-Do;Kim, Jin-Hoo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.101-106
    • /
    • 2006
  • Digital technology has been applied to marine seismic survey to develop data processing technology and multi-channel marine seismic survey. In result, high-resolution marine seismic survey ended in a success. Surveys are conducted for various purposes using various frequencies of acoustic sources. A low frequency source is used for deeper penetration and a high frequency source is used for higher resolution survey. In this study, a multi-source system was used for multi-channel marine seismic survey to acquire seismic sections of both low and high frequencies. Variations of depth of penetration and resolution would be used to achieve more accurate analysis of formations. In this study, the multi-source system consists of Bubble Pulser (400 Hz) for low frequency source and Sparker (1.5kHz) for high frequency source.

  • PDF

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

Development of Calibration System for Contact Transducer (초음파 탐촉자의 교정 시스템 개발)

  • Nam, Y.H.;Seong, U.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.294-299
    • /
    • 1999
  • In this paper, the calibration system for contact transducer has been developed to improve the reliability of the inspection result of ultrasonic testing on rotors. This system consists of signal processing parts: (oscilloscope, spectrum analyzer, pulser/receiver), standard block, and user interface program. Signal processing for the calibration system was performed quickly with high accuracy. The developed system has been applied to a practical calibration of probe using the non-destructive testing on rotors, and demonstrated high sensitivity and precision.

  • PDF

Ultrasonic C-scan System Development Using DSP (DSP 를 이용한 초음파 C-scan 시스템 개발)

  • Nam, Young-Hyun;Seong, Un-Hak;Kim, Jeong-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.32-39
    • /
    • 1999
  • Digital signal processor (DSP) is used to obtain the peak value and the time difference of ultrasonic signals, to make digital filter, and to derive mathematical transformation from analog circuit. In this study, C-scan system and control program have been developed to high speed data acquisition. This system consists of signal processing parts (DSP, oscilloscope, pulser/receiver, digitizer), scanner, and control program. The developed system has been applied to a practical ultrasonic testing in overlay weld, and demonstrated high speed with precision

  • PDF

EFFECTS OF ELECTROPORATION ON QUALITY OF ROOSTER SEMEN

  • Wu, H.T.;Huang, M.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.2
    • /
    • pp.175-178
    • /
    • 1995
  • Semen was collected from Taiwan commercial local chickens, the diluted sperm suspension were placed in the Gene Pulser cuvette for electroporation. The motility, mortality and abnormality of spermatozoa were evaluated. The fertility and hatchability were also investigated. The results showed that smaller motility and greater mortality or abnormality than the control were found when the capacitances were increased either for spermatozoa treated with small capacitances(0.25, 1, 3 and $25{\mu}$ FD) or treated with high capacitances (125, 250, 500 and $960{\mu}$ FD). In general, greater field strengths also resulted in smaller motility and greater mortality or abnormality of spermatozoa. Although the electroporation decrease the fertility there were no effect on the hatchability.

Comparison of the Model-predicted and Measured Target Strength of Cuttlebones from Golden Cuttlefish Sepia esculenta (갑오징어의 갑에 대한 모델 예측과 측정 반사강도의 비교)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.2
    • /
    • pp.209-217
    • /
    • 2020
  • The purpose of this study was to compare the model-predicted and experimentally measured target strength (TS) of golden cuttlefish Sepia esculenta cuttlebones. Ultrasonic signals used to estimate frequency-dependent TS and the speed of sound in cuttlebones were measured by pulse-echo and through-transmission techniques, using a chirp sonar system and an ultrasonic pulser/receiver system under controlled laboratory conditions. The model appeared to slightly underestimate the predicted TS values in the frequency range of 100-160 kHz. However, there was good agreement between the predicted and measured TS values in the frequency range of 160-200 kHz. The significant similarity between the model-predicted and experimentally measured TS values supports the use of the Kirchhoff-ray mode (KRM) model for acoustic scattering analysis of cuttlebones. Accordingly, we concluded that the KRM model can be used as a tool to evaluate the frequency-dependent variability of TS due to changes in golden cuttlefish swimming depth.

The Research on NAUT Characteristics Evaluation by Defection Image (결함 화상화를 통한 NAUT 특성평가 연구)

  • Na, Sun-Young;Kim, Jae-Yeol
    • Tribology and Lubricants
    • /
    • v.26 no.6
    • /
    • pp.341-345
    • /
    • 2010
  • The NAUT(Non contact Air coupled Ultrasonic Testing) is one of the ultrasonic wave inspection methods. It compensates High power ultrasound Pulser Receiver, pre-amp, air probe of high sensitivity in air to generate loss energy by NAUT methods. Generally, in case of ultrasound inspection, it applies contact methods by using couplant. However it can inspect of UT without couplant by this NAUT. The ultrasound transmission reception is composed in stable condition in NAUT. It can inspect high low material or the specimen of rough part, the narrow spot, too. The spot welding is applying the inosculation of automobile component, car body, all boards. The CFRP is necessity of NDE because of the solidity changes material according to lamella tearing. Therefore it checked on realization whether and commercialization in the spot welding and CFRP inspection that the NAUT would be applied them.

Marine Seismic Survey using a Multi-source System (다중음원을 이용한 다중채널 해양 탄성파 탐사)

  • Kim, Hyun-Do;Kim, Jin-Hoo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.209-210
    • /
    • 2006
  • Digital technology has been applied to marine seismic survey to develop data processing technology and multi-channel marine seismic survey. In result, high-resolution marine seismic survey ended in a success. Surveys are conducted for various purposes using various frequencies of acoustic sources. A low frequency source is used for deeper penetration and a high frequency source is used for higher resolution survey. In this study, a multi-source system was used for multi-channel marine seismic survey to acquire seismic sections of both low and high frequencies. Variations of depth of penetration and resolution would be used to achieve more accurate analysis of formations. In this study, the multi-source system consists of Bubble Pulser(400 Hz) for low frequency source and Sparker(1.5 kHz) for high frequency source.

  • PDF

Geophysical Exploration on Unconformity-type Uranium Deposit in Athabaska Basin, Canada (캐나다 아타바스카 분지 부정합형 우라늄광상 물리탐사 사례)

  • You, Young-June;Kim, Jae-Chul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.05a
    • /
    • pp.73-87
    • /
    • 2009
  • Geophysical survey for unconformity-type uranium deposit applied to this study area in Athabaska Basin, Canada were carried out airborne TEM and magnetic, resistivity-induced polarization (DC-IP), puser seismic reflection and well-logging method. The results of airborne survey interpreted the lithological boundary, geological structures, and conductors. Also, these results decided to main targets for ground DC-IP survey. The Low resistivity and the high chargeability slices of 3D modeling interpreted from DC-IP survey response for conductors related to hydrothermal alteration zones and fault-controlled graphitic zones occurring at the unconformity-type uranium deposit, and they confirmed by diamond drilling. Seismic results interpreted to lake bottom surface, alluvium layer and intra-sandstone faults. We suggest the resonable field data acquisition of DC-IP method on the land or the lake in Athabaska Basin.

  • PDF