• Title/Summary/Keyword: Pulsed-CW

Search Result 47, Processing Time 0.026 seconds

Preparation of Polymer Thin Films of Pentafluorostyrene via Plasma Polymerization

  • Ahn, C.J.;Yoon, T.H.
    • Journal of Adhesion and Interface
    • /
    • v.7 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • Polymer thin films of pentafluorostyrene (PFS) were prepared by RF plasma (13.56 MHz) polymerization in continuous wave (CW) mode, as a function of plasma power and monomer pressure. Conditions for film preparation were optimized by measuring the solvent resistance of plasma polymer thin films in DMAc, NMP, THF, acetone and chloroform, as well as by evaluating the optical clarity via UV-VIS measurements. Pulsed mode plasma polymerization was also utilized to enhance the optical properties of the films by varying the period of on-time and duty cycle. Finally, the films were subjected to refractive index measurements and analyzed by ${\alpha}$-step, TGA and FT-IR.

  • PDF

Stimulated Brillouin scattering in optical fiber for pulsed lights compared to continuous wave lights (광펄스신호와 연속광원을 이용한 광섬유내의 stimulated Brillouin scattering 비교 연구)

  • 이한협;최현범;이동한;남성현;김대연;윤형규
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.338-342
    • /
    • 2003
  • We have studied the properties of stimulated Brillouin scattering (SBS) in an optical fiber using optical pulses and continuous wave light. We find that the thresholds for SBS are the same when the averaged power of pulse light is the same as the power of cw light. From this result, the SBS threshold of pulse light can be deduced from that of continuous wave light, which can be obtained easily and accurately.

Experimental Verification of Multipactor Sensitivity for S-band Diplexer (S 대역 Diplexer에 대한 Multipactor 민감도 시험)

  • Choi, Seung-Woon;Kim, Day-Young;Kwon, Ki-Ho;Lee, Yun-Ki
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.83-91
    • /
    • 2007
  • An experimental verification of multipactor(MP) discharge for S-band diplexer as a sample DUT for space application by an in-house MP test facility is proposed. The designed diplexer having two BPFs for Rx and Tx is applied to a design of five pole inter-digital cavity type band pass filter with chebyshev response, it has 2.7 % bandwidth centered at 2.232 and 2.055 GHz for Rx, Tx, respectively. To avoid the MP discharge, the accurate design and analysis methods based on 3D EM field analysis are considered. The proposed in-house MP test facility consists of a phase detecting system using a doubly balanced mixer as a simple, low cost and real time MP test method compared with results of previously well-known MP detection systems as cross reference methods. The calculated MP threshold RF input power is 43.13 dBm. The measured one is 43 dBm and 44 dBm for CW, pulsed mode test, respectively.

  • PDF

Selective Extraction of a Single Optical Frequency Component from an Optical Frequency Comb (광 주파수 빗으로부터 단일 광 주파수 성분의 선택적 추출)

  • Han Seb Moon
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.225-234
    • /
    • 2023
  • Mode-locked pulse lasers have a temporal periodicity up over a short period of time. However, in the time-frequency domain, a pulsed laser with temporal periodicity is described as an optical frequency comb with constant frequency spacing. Each frequency component of the optical frequency comb in the frequency domain is then a continuous-wave (CW) laser with hundreds of thousands of single-frequency-component CW lasers in the time domain. This optical frequency comb was developed approximately 20 years ago, enabling the development of the world's most precise atomic clocks and precise transmission of highly stable optical frequency references. In this review, research on the selective extraction of the single-frequency components of optical frequency combs and the control of the frequency components of optical combs is introduced. By presenting the concepts and principles of these optical frequency combs in a tutorial format, we hope to help readers understand the properties of light in the time-frequency domain and develop various applications using optical frequency combs.

A Study of Weldability for Pure Titanium by Nd:YAG Laser(I) - Weld Properties with Shield Conditions - (순티타늄판의 Nd:YAG 레이저 용접성에 관한 연구(I) - 실드 조건에 따른 용접특성 -)

  • Kim, Jong-Do;Kwak, Myung-Sub;Kim, Chang-Soo
    • Journal of Welding and Joining
    • /
    • v.27 no.5
    • /
    • pp.55-61
    • /
    • 2009
  • Pure titanium and its alloys have good formability, excellent corrosion resistance and high strength to weight ratios. Therefore, it has been using to heat exchangers, offshore plants, sports equipments, and etc. As broad as its application fields, it also increases welding locations. Conventional GTAW and GMAW are very popular welding methods of titanium, but it has a high heat input and wide HAZ. It has a possibility of inducing Stress Corrosion Cracking. So, laser welding method has been using to get reliable welds by reducing heat input. Weld beads change its color to silver, gold, brown, blue, and gray by shied conditions. And the closer to gray, the more oxidize, nitride and embrittlement. The most effective atom to embrittlement was nitrogen. And shield gas flow was not so effective over the constant flow rates. In this study, weld properties of the pure titanium were investigated by pulsed & CW Nd:YAG lasers and evaluated by various shield conditions. And It is observed that nitrogen is more effective to oxidation and embrittlement of titanium compared with oxygen by oxygen and nitrogen quantitative analysis.

Terahertz (THz) imaging technology for therapeutic and diagnostic applications of cancer incorporating with radiopharmaceutical fields

  • Min, Sun-Hong;Cho, Ilsung;Park, Chawon;Jung, Wongyun;Hwang, Won Taek;Kim, Minho;Lee, Kyo Chul;Lee, Yong Jin;Lim, Sang Moo;Hong, Bong Hwan
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.2
    • /
    • pp.120-128
    • /
    • 2019
  • Radiopharmaceuticals include therapeutic radiopharmaceuticals and diagnostic radiopharmaceuticals. Therapeutic radiopharmaceuticals are administered to the body and ingested at specific organs to detect radiation emitted from the site and to construct an image to diagnose the disease. Diagnostic radiopharmaceuticals are used to treat diseases by killing cells with radiation emitted from radiopharmaceuticals, such as cancer cells, vascular endothelial cells, arthritis, and Alzheimer's disease. The application possibilities of terahertz imaging technology for the combination of radiopharmaceuticals and molecular imaging medicine are discussed and experimental methods are presented. Terahertz imaging is expected to be a powerful technique because of the effective piercing feasibility, which enables to perform safe and high resolutive imaging. To investigate the response of cell to the terahertz wave, both the pulsed and CW THz wave systems are employed. THz imaging of a rat's paraffin-embedded epithelial cell with tumor is studied in advance.

이중 주파수를 사용하는 펄스 플라즈마 특성에 관한 연구

  • Choe, Sang-Uk;Seo, Jin-Seok;Kim, Tae-Hyeong;Kim, Gyeong-Nam;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.219.1-219.1
    • /
    • 2014
  • 전자소자 산업의 미세화 및 대형화에 따라 플라즈마 밀도, 전위, 온도, 균일도 등 과 같은 플라즈마 특성을 제어하는 것은 차세대 플라즈마 장치 개발에 있어 매우 중요한 요소라고 할 수 있다. 특히, 급격한 소자의 미세화에 따라 플라즈마 공정을 통해 발생할 수 있는 damage는 큰 issue가 되어 왔고, 많은 연구자들은 이를 해결하기 위해서 다각적인 노력을 진행해 왔다. 그중 높은 전자 온도는 높은 전자 에너지에 의해 공정 중 소자를 손상 시키는 주된 원인이라고 보고되고 있으며, 이에 대한 제어기술은 매우 중요하다고 할 수 있다. 본 연구에서는 서로 다른 두 개의 내/외측으로 나뉘어진 나선형 모양의 ICP 안테나를 이용 하여 연구를 진행하였다. 내측의 안테나에는 2 MHz를 연결 하였으며, 외측의 안테나에는 13.56 MHz를 연결 하였으며, 내/외측 안테나에 각각 pulse mode로 입력전력을 인가해 줌으로써 플라즈마의 특성을 관찰하였다. Pulse / CW (Continuous Wave) mode에 있어서 전자온도의 측정을 위해 emissive probe 를 이용하여 plasma potential과 floating potential을 측정하였으며, 이를 통하여 전자온도를 계산하여 구할 수 있었다. Duty ratio 및 pulsing frequency의 변화에 따른 전자온도의 변화를 확인 할 수 있었으며, 그에 따른 플라즈마 균일도를 ion saturation current를 측정함으로써 관찰할 수 있었다. 실제 식각 공정에 있어서 Pulsing 조건에 따른 식각 특성을 관찰하기 위해, SiO2, ACL (Amorphous Carbon Layer)에 대해 식각을 진행하였으며, 식각 메커니즘 분석을 위해 이온에너지 분포의 변화를 PSM (Plasma Sampling Mass-spectroscopy)을 이용하여 측정하였다.

  • PDF

Effect of the 100Hz PWM Low Power Light Irradiation in Proliferation of NTacSam:SD Bone-marrow Cell (NTacSam:SD 골수 세포의 증식에 100Hz PWM 저출력 광 조사가 미치는 효과)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Lee, Ho-Sic;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04b
    • /
    • pp.10-11
    • /
    • 2008
  • We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for bone marrow cells. MIT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590nm transmittance of ELISA reader. As a result, the cell increase of bone marrow cells was verified in irradiation group as compared to non-irradiation group.

  • PDF

Development of a 3.6 MW, $4\;{\mu}s$, 200 pps Pulse Modulator for a High Power Magnetron (고출력 마그네트론 구동용 3.6 MW, $4\;{\mu}s$, 200 pps 펄스 모듈레이터 개발)

  • Jang Sung-Duck;Kwon Sei-Jin;Bae Young-Soon;Oh Jong-Seok;Cho Moo-Hyun;Namkung Won;Son Yoon-Kyoo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.120-126
    • /
    • 2005
  • The Korean Superconducting Tokamak Advanced Research (KSTAR) tokamak device is being constructed to perform long-pulse, high-beta, advanced tokamak fusion physics experiments. The long-pulse operation requires the non-inductive current drive system such as the Lower-Hybrid Current Drive (LHCD) system. The LHCD system drives the non-inductive plasma current by means of C-band RF with 2-MW CW power and 5-GHz frequency. For the LHCD test experiments, an RF test system is developed. It is composed of a 5-GHz, 1.5-MW pulsed magnetron and a compact pulse modulator with $4\;{\mu}s$ of pulse width. The pulse modulator provides the maximum output voltage of 45 kV and the maximum current of 90 A. It is composed of 7 stages of Pulse Forming Network (PFN), a thyratron tube (E2V, CX1191D), and a pulse transformer with 1:4 step-up ratio. In this paper, the detailed design and the performance test of the pulse modulator are presented.

Continuous and Pulsed Laser Induced Copper Deposition on Silicon(Si) from Liquid Electrolyte (전해질 용액내의 실리콘 단결정 표면에서 레이저로 유기되는 구리 침착)

  • 유지영;안창남;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.50-54
    • /
    • 1992
  • Maskless depositon of copper onto n-doped and p-doped Si in an aqueous copper sulfate solution is investigated. On p-doped Si substrates, microscopic $(~10\mu\textrm{m}$) copper spots are deposited by illuminating continuous wave $Ar^+$ laser beam of wavelength 514.5 nm. Copper deposition on n-doped Si substrates is also achieved by shinning second harmonic pulses $(pulse width~25 nsec, \lambda=530 nm)$ of a passively Q-switched Nd:YAG laser. The observed deposition is attributed to the electric field resulting from the Galvanic potential of a semiconductor-electrolyte junction.

  • PDF