• Title/Summary/Keyword: Pulsed I-V

Search Result 86, Processing Time 0.026 seconds

Wideband RF Radiation from a Nonlinear Transmission Line with a Pre-magnetized Ferromagnetic Core

  • Ahn, J.-W.;Karelin, S.Y.;Krasovitsky, V.B.;Kwon, H.-O.;Magda, I.I.;Mukhin, V.S.;Melezhik, O.G.;Sinitsin, V.G.
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.450-459
    • /
    • 2016
  • Experimental results and data of numerical simulations are presented, concerning generation of wideband radio frequency (RF) oscillations in a nonlinear transmission line (NLTL) which contains a pre-magnetized core of ferrite material. Emphasis is made on the means for extracting the RF signal from the line, in order to radiate it into free space. Antennas of two types that can be used for the purpose are considered, both featuring a coaxial design. This permits availing of the principal advantages of coaxial systems, such as operation in the mode of a traveling TEM wave; wide range of the transmitted frequencies, and a reasonably simple design. The antennas studied, specifically a disc-cone dipole (DCD) and an impulse reflector antenna ('Half-IRA', or HIRA type) differ significantly in effective width of the radiated spectrum and in spatial characteristics of the radiated field in far region.

TWO-COLOR VR CCD PHOTOMETRY OF OLD NOVA V603 AQUILAE

  • Andronov Ivan L.;Ostrova Nataliya I.;Kim, Yong-Gi;Burwitz V.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.211-222
    • /
    • 2005
  • Results of 6 nights of CCD VR photometry of the nova-like variable V603 Aquilae (Nova Aquilae 1918) obtained at the Mallorcian 35-cm telescope in July 2004 are reported. The ephemeris for the superhump maximum is Max.HJD=2453213.60546(96)+0.14813(10)E. The waves with $3.^d9,\;1.^d4,\;0.^d135$ are statistically significant, which may be interpreted as the negative superhump-orbital, the beat periods (negative superhump- positive superhump) and the negative superhump with low amplitude, respectively. Another possible time-scale is $0.^d8,$ which has no coincidence with the beat periods. Quasi-periodic oscillations with an effective period of 18 minutes have been detected, which are close to 15.6 minutes reported by some authors. Their effective semi-amplitudes are $^m.045\;and\;0^m.051$ for V and R, respectively. This corresponds to the 0.12 mag excess in the color index V-R as compared with the mean color, which can be understood as the pulsed emission in the hotter inner parts of the accretion disk, similar to that observed in TT Ari and MV Lyr.

Measurement of Neutron Capture Gamma-ray Spectrum of Natural Gold in the keV Energy Region

  • Lee, Jae-Hong;Lee, Sam-Yol;Lee, Sang-Bock;Lee, Jun-Haeng;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2007
  • keV-neutron capture gamma-ray spectrum of $^{197}Au$(natural gold) sample have been measured in neutron energy range from 10 to 90 keV using the 3-MV pelletron accelerator of the Research Laboratory for Nuclear Reactors at the Tokyo Institute of Technology. Pulsed keV neutrons were produced from the $^7Li(p,n)^7Be$ reaction by bombarding on the $^7Li$ target with the 1.5-ns bunched proton beam. The incident neutron spectrum on the Au sample was measured by a $^6Li$-glass scintillation detector and TOF method. Capture gamma-rays from Au sample were measured by anti-Compton NaI(TI) spectrometer. Five average neutron energy regions were selected to obtain the neutron capture spectrum. Several gamma-ray peaks in the spectrum were found in the present experiment.

  • PDF

The Effect of Donor Antigen-pulsed Dendritic Cells on Survival of Skin Allograft in a Rat Model (흰쥐 모델에서 공여항원에 감작된 수지상세포가 피부동종이식의 생착에 미치는 영향)

  • Eun, Seok Chan;Kim, Byung Jun;Kim, Jin Hee;Heo, Chan Yeong;Baek, Rong Min;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.367-372
    • /
    • 2008
  • Purpose: Prevention of acute rejection in skin allografts without continuous immunosuppression lacks reports in worldwide literature. Needs for chronic immunosuppression preclude the use of tissue allograft as a routine surgical reconstructive option. Recently dendritic cells(DC) gained considerable attention as antigen presenting cells that are also capable of immunologic tolerance induction. This study assesses the effects of alloantigen-pulsed dendritic cells in induction of survival increase in a rat skin allograft model. Methods: Recipient-derived dendritic cells were harvested from rat whole blood and cultured with GM-CSF(200 ng/mL) and IL-4(8 ng/mL) for 2 weeks. Then donor-specific alloantigen pulsed dendritic cells were reinjected into tail vein before skin graft. The rat dorsal skin allografts were transplanted in 5 subgroups. Groups: I) untreated, II) anti-lymphocyte serum(ALS, 0.5 mL), III) FK-506(2 mg/kg), IV) DCp, VI) DCp and FK-506. Graft appearance challenges were assessed postoperatively. Results: The group V(DC and FK-506 treated) showed longest graft survival rate(23.5 days) than other groups; untreated(5.8 days), ALS(7.2 days), FK-506 (17.5 days), DCp(12.2 days). Conclusion: Donor antigen pulsed host dendritic cell combined with short-term immunosuppression prolong skin allograft survival and has potential therapeutic application for induction of donor antigen specific tolerance.

The comparative study of pure and pulsed DC plasma sputtering for synthesis of nanocrystalline Carbon thin films

  • Piao, Jin Xiang;Kumar, Manish;Javid, Amjed;Wen, Long;Jin, Su Bong;Han, Jeon Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.320-320
    • /
    • 2016
  • Nanocrystalline Carbon thin films have numerous applications in different areas such as mechanical, biotechnology and optoelectronic devices due to attractive properties like high excellent hardness, low friction coefficient, good chemical inertness, low surface roughness, non-toxic and biocompatibility. In this work, we studied the comparison of pure DC power and pulsed DC power in plasma sputtering process of carbon thin films synthesis. Using a close field unbalanced magnetron sputtering system, films were deposited on glass and Si wafer substrates by varying the power density and pulsed DC frequency variations. The plasma characteristics has been studied using the I-V discharge characteristics and optical emission spectroscopy. The films properties were studied using Raman spectroscopy, Hall effect measurement, contact angle measurement. Through the Raman results, ID/IG ratio was found to be increased by increasing either of DC power density and pulsed DC frequency. Film deposition rate, measured by Alpha step measurement, increased with increasing DC power density and decreased with pulsed DC frequency. The electrical resistivity results show that the resistivity increased with increasing DC power density and pulsed DC frequency. The film surface energy was estimated using the calculated values of contact angle of DI water and di-iodo-methane. Our results exhibit a tailoring of surface energies from 52.69 to $55.42mJ/m^2$ by controlling the plasma parameters.

  • PDF

Exciting High Frequency Oscillations in a Coaxial Transmission Line with a Magnetized Ferrite

  • Ahn, J.-W.;Karelin, S.Y.;Kwon, H.-O.;Magda, I.I.;Sinitsin, V.G.
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.460-465
    • /
    • 2015
  • The paper presents methodologies and results concerning one- and two-dimensional numerical modeling of radio frequency oscillations in a coaxial transmission line fed with a short pulse of electric current. The line is partially filled with a ferrite material, magnetized longitudinally close to saturation. The 2D model has permitted analyzing, for the first time in the art, the spatial structure and dynamics of the wave field within the radially non-uniform cross-section planes of the non-linear and dispersive guiding structure. This opens ways for optimizing size parameters of the line and the extent to which it is filled with the ferromagnetic material, thus increasing the line's electric strength and intensity of the r.f. oscillations.

Properties of YBCO Step-edge Junction Fabricated on Different Crystal Orientation of Sapphire Substrate (사파이어 기판의 다른 결정방향 위에 제작된 YBCO step-edge 접합의 특성)

  • H. R. Lim;I-S Kim;Y. K. Park;J. C. Park
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.60-64
    • /
    • 2001
  • We have studied properties of step-edge Junction prepared with crystal orientation of sapphire substrate. The Step on sapphire substrates fabricated by conventional photolithography method and Ar ion milling method. $CeO_2$ buffer layer and in-situ YBCO thin film were deposited on the stepped sapphire substrates by a pulsed laser deposition method with the predetermined optimized condition. The step angle was centre fled low angle of about $25^{\circ}$. The YBCO film thickness was varied to obtain various thickness ratios of the film to the step height in a range from 0.7 to 1.2. I-V curves of junction were showed RSJ-behavior, double junction structure, and hysteresis due to the crystal orientation of substrate.

  • PDF

Development of neutron time-of-flight measurement system for 1.7-MV tandem proton accelerator with lithium target

  • Lim, Soobin;Kim, Donghwan;Kang, Jin-Goo;Dang, Jeong-Jeung;Lee, Pilsoo;Kim, Geehyun;Chung, Kyoung-Jae;Hwang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.437-441
    • /
    • 2022
  • In this study, we developed a neutron time-of-flight (nTOF) measurement system for a 1.7-MV tandem proton accelerator with a target covered with 300-nm-thick lithium (Li) layer. With implementation of beam chopping module after its ion source, the accelerator is configured to operate in pulsed-beam mode with a pulse width <50 ns at 20-kHz repetition rate. This enables the gamma flash-type nTOF measurement system to identify the neutron generated with 3-MeV proton beam energy. The nTOF system consists of a 30" cylindrical NaI(Tl) and four stilbene scintillation detectors. The NaI(Tl) scintillator is placed 50 cm from the Li target to measure the time of beam irradiation on the target, and the stilbene detectors are placed 2 and 2.4 m away to measure nTOF at each location. The nTOF system successfully measured the generated neutron energy at irradiated proton energies of 2.6 and 3.0 MeV with an average energy resolution of 15%.

Design and Test Results of High-Power Pulse Generator System for Industrial Accelerator Application (산업용 가속기용 고출력 펄스시스템의 설계와 시험)

  • Jang, S.D.;Kim, S.H.;Yang, H.Y.;Cho, M.H.;Ko, I.S.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1370_1372
    • /
    • 2009
  • A conventional linear accelerator system requires a flat-topped pulse with less than $\pm$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A a line-type pulsed modulator is widely used in pulsed power circuits for applications such as accelerators, radar, medical radiation, or ionization systems. The high-voltage pulse generator system with an output voltage of 284 kV, a pulse width of $10{\mu}s$, and a rise time of $0.84{\mu}s$ has been designed and fabricated to drive a klystron which has 30-MW peak and 60-kW average RF output power. The high-voltage test was performed using the klystron load. This thesis describes the design and test results of high-power pulse generator system for industrial accelerator application. The experimental results were analyzed and compared with the design.

  • PDF

A Study on Thermal Properties of Ethylene Glycol Containing Copper Oxide Nanoparticles (산화구리 나노분말을 포함하는 에틸렌글리콜 용액의 열전특성에 관한 연구)

  • Kim, Chang-Kyu;Lee, Gyoung-Ja;Rhee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.17 no.4
    • /
    • pp.276-280
    • /
    • 2010
  • In the present work, ethylene glycol-based (EG) copper oxide nanofluids were synthesized by pulsed wire evaporation method. In order to explode the pure copper wire, high voltage of 23 kV was applied to the both ends of wire and argon/oxygen gas mixture was used as reactant gas. EG-based copper oxide nanofluids with different volume fraction were prepared by controlling explosion number of copper wire. From the transmission electron microscope (TEM) image, it was found that the copper oxide nanoparticles exhibited an average diameter about 100 nm with the oxide layer of 2~3 nm. The synthesized copper oxide consists of CuO/$Cu_2O$ phases and the Brunauer Emmett Teller (BET) surface area was estimated to be $6.86\;m^2\;g^{-1}$. From the analyses of thermal properties, it is suggested that viscosity and thermal conductivity of EG-based copper oxide nanofluids do not show temperature-dependent behavior over the range of 20 to $90^{\circ}C$. On the other hand, the viscosity and thermal conductivity of EG-based copper oxide nanofluids increase with volume fraction due to the active Brownian motion of the nanoparticles, i.e., nanoconvection.