• Title/Summary/Keyword: Pulsed

Search Result 2,893, Processing Time 0.032 seconds

Densification of Al2O3 Nanopowder by Magnetic Pulsed Compaction and Their Properties (자기펄스 가압성형법에 의한 알루미나 나노분말의 치밀화 및 특성 평가)

  • Kang, R.C.;Lee, M.K.;Kim, W.W.;Rhee, C.K.;Hong, S.J.
    • Journal of Powder Materials
    • /
    • v.15 no.1
    • /
    • pp.37-45
    • /
    • 2008
  • This article presents the challenges toward the successful consolidation of $Al_2O_3$ nanopowder using magnetic pulsed compaction (MPC). In this research the ultrafine-structured $Al_2O_3$ bulks have been fabricated by the combined application of magnetic pulsed compaction (MPC) and subsequent sintering, and their properties were investigated. The obtained density of $Al_2O_3$ bulk prepared by the combined processes was increased with increasing MPC pressure from 0.5 to 1.25 GPa. Relatively higher hardness and fracture toughness in the MPCed specimen at 1.25 GPa were attributed to the retention of the nanostructure in the consolidated bulk without cracks. The higher fracture toughness could be attributed to the crack deflection by homogeneous distribution and the retention of nanostructure, regardless of the presence of porosities. In addition, the as consolidated $Al_2O_3$ bulk using magnetic pulsed compaction showed enhanced breakdown voltage.

STUDY ON HIGH SPEED WELDING IN GTA WELDING PROCESS

  • Cui Li;Jeong, Ho-Shin;Park, Byung-Il;Kim, Sung-Kab
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.89-93
    • /
    • 2002
  • A study of noticeable improvement in welding speed in thin-plate Type 304 stainless steels gas tungsten arc (GTA) welding was investigated. The welding speeds were increased to more than 3m/min, up to 8m/min. During the welding, Direct Current Straight Polarity (DCSP) and pulsed current GTA welding processes were carried out, respectively. The appropriate high speed welding parameters were established while achieving a high quality weld. After this, Erichsen test and tensile test were performed. The results obtained wert summarized as following: ultra high speed welding for thin-plate Type 304 could be satisfactorily welded with high speed from 3m/min to 8m/min in both DCSP and pulsed GTA welding; Increasing welding speed was found to decrease the ductility, tensile strength md elongation of welded joint; The optimal frequency would be 200Hz-500Hz for high speed welding in pulsed current welding; DCSP welding could obtain the better results of Erichsen test and tensile test than those of pulsed current welding obtained.

  • PDF

IMPROVEMENT OF GAS TUNGSTEN ARC WELDABILITY FOR FERRlTIC STAINLESS STEELS

  • Cui Li;Jeong, Ho-shin;Park, Byung-Il;Kim, Sung-Kab
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.107-112
    • /
    • 2002
  • Ferritic stainless steels would be the most important alloys under the chloride environment. They are a cheaper alternative to austenitic stainless steels [1]. The present study is related to gas tungsten arc welding (GTAW) characteristics of Type 444 stainless steels. The heat of welding leads to grain coarsening in the HAZ and in the weld metal of ferritic stainless steels because they solidify directly from the liquid to the ferritc phase without any intermediate phase transformation. It is therefore recommended that these alloys be welded with a low heat input and at high welding speeds. Attempts to improve weldability were made by using of direct current straight polarity (DCSP) and pulsed current GTAW processes in this study. Measuring weld bead, grain size and Erichsen test were performed and the effects of heat input, pulse frequency on the weld metal and HAZ were studied. The main results were obtained as followings: decreasing heat input was effective to control the width of weld both in DCSP welding and in pulsed current welding; pulsed current welding was found to refine the grain size effectively and the finest grain size was found at the frequency of 150Hz in pulsed current welding; it was found that decreasing heat input also refine the HAZs effectively and the frequency had no different effect on HAZ at the same heat input; the ductility could be improved effectively in pulsed current welding.

  • PDF

Degradation of methyl orange by pulsed corona discharges in aqueous solution (수중 펄스코로나 방전에 의한 메틸오렌지 제거 특성)

  • Lee, Hyeon-Don;Kim, Jong-Oh;Kim, Hyoung-Kab;Chung, Jae-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2012
  • A laboratory experiment on methyl orange degradation in pulsed corona discharges was carried out. Effects of operating parameters such as applied voltage, pH, conductivity and initial concentration on methyl orange degradation were investigated. The pulsed corona discharges decreased the pH of solution and increased conductivity, probably due to products generated from methyl orange degradation by corona discharges. The decrease of initial pH enhanced the methyl orange degradation. The methyl orange degradation was fastest in $100{\mu}S/cm$ conductivity solution, followed by 50 and $200{\mu}S/cm$, indicating that $100{\mu}S/cm$ is the most favorable in the aspect of radical generation among the experimented conditions. The methyl orange of initial concentration from 20 to 60mg/L was effectively degraded in pulsed corona discharges. The lower initial concentration of methyl orange, the faster degradation was observed.

In vitro Investigation of the Harmful Effects of Smoke Plume Produced by Pulsed Nd: YAG Laser Treatment (Pulsed Nd : YAG 레이저조사시 발생되는 연기의 유해효과에 관한 실험실적 연구)

  • Kyung-Hun Kim;Keum-Back Shin;Bok Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.283-289
    • /
    • 1995
  • 레이저가 의학영역에서 사용된 후 구강내 연조직과 경조직 병소에 대한 임상적 적용에 관한 관심이 커져왔다. 레이저가 조사되는 부위에서는 대부분 연기가 발생한다. 이 경우 병원체가 존재하는 병소에 대한 레이저치료시 발생되는 연기속에 병원체가 포함되어 이Tekas 환자와 술자는 이의 흡입가능성이 크므로 균혈증 및 상기도나 호흡계의 의원성 감염이 유발될 수 있다. 저자는 레이저치료시 발생되는 연기속에 병원체가 포함되어 있는지의 여부를 규명하기위해 각각 10개의 실험군에 통기성 미생물인 Escherichia coli(E.coli)가 배양된 brain geart infusion (BHI) 배지와 E.coli 가 존재하는 치근단 병소를 실험적으로 만든 후 각각 pulsed Nd:YAG 레이저를 조사해 연기를 채취, 배양, 분석하여 다음과 같은 결과를 얻었다. 1. Pulsed Nd:YAG 레이저를 E. colir 배양된 agar substrate 와 실험적으로 만들어진 치근단부위의 E.coli 현탁액에 조사시 발생된 연기에서 처음 접종된 것과 같은 E.coli가 검출되었다. 2. 감염병소에 pulsed Nd:YAG 레이저를 조사시 발생되는 연기의 유해효과로부터 환자와 술자 및 보조자의 보호를 위해 효과적인 흡입기를 사용이 권장된다.

  • PDF

A High Precision Pulsed Field Magnetometer for Magnetic Properties Measurements of Rare Earth Magnets (희토류 영구자석의 자성측정을 위한 고감도 펄스마그네토미터)

  • Kim, Y.B.;Kapustin, G.A.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.4
    • /
    • pp.250-255
    • /
    • 2005
  • A 8 MA/m-class pulsed field magnetometer has been constructed by composing a pulsed field magnet, a pickup coil, analog integrators, a digital storage oscilloscope and a personal computer. For precision measurements, a 3-axis compensation principle has been applied for the fabrication of pickup coil, and the compensation level of the order of $10^{-6}$ and the sensitivity of $5{\cdot}10^{-7}\;Am^2$ for magnetic moment have been obtained. The high sensitivity of the magnetometer is good enough for measurements of magnetic properties of rare earth magnets in small size or thin films shorter than $3\;mm{\phi}$ in diameter.

Performance Comparison of Radar Signal Active Cancellation Systems According to Pulsed-CW Parameter Estimation Error (Pulsed-CW 신호 파라미터 추정 오차에 따른 레이더 신호 능동 상쇄 성능 비교)

  • Choi, Seung-Kyu;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.10
    • /
    • pp.60-66
    • /
    • 2011
  • In this paper, we analyze the effects of estimation error in the active cancellation signal, which is intended to counter the pulsed-CW signal of a hostile radar. We also examine the effects of estimation error in maximum-likelihood estimation (MLE) and quadratic interpolation scheme from a radar signal active cancellation viewpoint. Then, we modify the correlation-based error compensation scheme which mitigates the estimation error of MLE to improve the performance of the active cancellation signal. Finally, we present simulation results to show that the correlation-based scheme has better performance than the other in terms of radar signal active cancellation.

Effects of Pulse Modulations on Particle Growth m Pulsed SiH4 Plasma Chemical Vapor Deposition Process (펄스 SiH4 플라즈마 화학기상증착 공정에서 입자 성장에 대한 펄스 변조의 영향)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.173-181
    • /
    • 2006
  • We analyzed systematically particle growth in the pulsed $SiH_4$ plasmas by a numerical method and investigated the effects of pulse modulations (pulse frequencies, duty ratios) on the particle growth. We considered effects of particle charging on the particle growth by coagulation during plasma-on. During plasma-on ($t_{on}$), the particle size distribution in plasma reactor becomes bimodal (small sized and large sized particles groups). During plasma-off ($t_{off}$), there is a single mode of large sized particles which is widely dispersed in the particle size distribution. During plasma on, the large sized particles grows more quickly by fast coagulation between small and large sized particles than during plasma-off. As the pulse frequency decreases, or as the duty ratio increases, $t_{on}$ increases and the large sized particles grow faster. On the basis of these results, the pulsed plasma process can be a good method to suppress efficiently the generation and growth of particles in $SiH_4$ PCVD process. This systematical analysis can be applied to design a pulsed plasma process for the preparation of high quality thin films.

  • PDF

Induction of 90K-specific Cytotoxic T Lymphocytes for Colon Cancer Immunotherapy

  • Lee, Ji-Hee;Park, Myung-Suk;Chung, Ik-Joo
    • IMMUNE NETWORK
    • /
    • v.10 no.6
    • /
    • pp.206-211
    • /
    • 2010
  • Background: Dendritic cell (DC)-based tumor vaccine is an attractive modality for the treatment of colon cancer because it has been recurred and produced few side effects in patients. Secretory glycoprotein 90K has been found at elevated level in various cancer tissues and sera. We investigated to establish a more effective DC vaccine for the treatment of colon cancer in which the levels of 90K are elevated. Methods: We obtained the concentrated 90K from 293T cells stably expressing 90K. DCs were cultured from peripheral blood monocytes, and a DC vaccine pulsed with tumor lysate was compared with a DC vaccine pulsed with 90K. We measured the functional activity for CTLs by using IFN-${\gamma}$-enzyme linked immunoabsorbent spot (ELISPOT) assay. Results: DCs pulsed with tumor lysate+90K exhibited the enhanced T cell stimulation, polarization of $\ddot{i}$ T cell toward Th1. The CTLs generated by DCs pulsed with 90K efficiently lysed HCT116 cells. The results indicate that 90K-speicifc-CTLs can recognize 90K proteins naturally presented by colon cancer cells. Conclusion: Our study suggests that 90K-specific CTLs generated by 90K-pulsed DCs could be useful effector cells for immunotherapy in colon cancer.

A Study on Operating Characteristics of the CO2 Laser with Inductively Pulsed Power System (유도형(誘導型) Pulsed Power 전원을 이용한 CO2 레이저 동작 특성에 관한 연구)

  • Kim, Geun-Yong;Min, Byoung-Dae;Kim, Yong-Cheol;Lee, Yu-Soo;Chung, Hyun-Ju;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1710-1713
    • /
    • 2002
  • Recently, the pulsed power system has been used to many applications. Such as remediation of environmental hazards, food sterilization, air pollution control E/P (Electrostatic Precipitator), DeNOx/DeSOx power system, ozone generator, high energy physics, and other power source applications. A pulse energy efficiency for load depends on the rising time, peak value. Pulse duration and impedance matching etc. The pulsed power system generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, we investigated operating characteristics of the CO2 laser using an inductively pulsed power system.

  • PDF