• Title/Summary/Keyword: Pulse-Diagnosis Data

Search Result 116, Processing Time 0.027 seconds

Ontology Representation of Pulse-Diagnosis Data and an Inference System for the Diagnosis Service (맥진 데이터의 온톨로지 표현과 진단 서비스 추론 시스템)

  • Yang, Dong-Il;Park, Sun-Hee;Lim, Hwa-Jung;Yang, Hae-Sool;Choi, Hyung-Jin
    • The KIPS Transactions:PartB
    • /
    • v.15B no.3
    • /
    • pp.237-244
    • /
    • 2008
  • In this paper, an infra-structure using the ontology based on the pulse information is proposed for the context-aware service of medical information system in ubiquitous computing environment. An diagnosis service inference system that represents the pulse data which was generated by the pulse-diagnosis with wearable signal, temperature, humidity, time, and other factors as ontology with artificial intelligence methods and describes the service scenario based on the ontology is designed and implemented.

Study on the Correlation between Sasang Constitution and the Data of Pulse Diagnosis Device - A Systematic Review in Korean Articles - (사상체질과 맥진기 검사 결과와의 상관성에 대한 연구 - 국내 논문에 대한 체계적 고찰 -)

  • Lee, Hye Yoon;Jung, A Ram;Son, Han Beom;Hwang, Man Suk;Lee, Jeong Won;Kim, Gyeong Cheol;Yun, Young Ju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.621-629
    • /
    • 2012
  • This study aimed to examine the possibility of data from pulse diagnosis device to be used for diagnosis of Sasang constitution. Systematic searches of 5 major Korean medical database were conducted for articles published up to May 2012. Searching key word was "Sasang" or "Constitution". Studies dealt with correlation between Sasang constitution and the pulse wave data from pulse diagnosis machine were included. Totally 2886 studies are searched and 3 studies are added from references of evaluated articles. Among them, 12 studies were met our inclusion criteria (2 Xishu Mac, 2 Self-made pulse diagnosis machine, 8 3D-Mac). Three of the eight 3D-Mac studies intended to develop a formula of constitutional differential diagnosis, 2 studies compared variables by Sasang constitution in healthy group and 3 studies compared variables by Sasang constitution in healthy group and special disease group. They all reported some significant variables, however results are not consistent between studies. The accuracy of the formula of constitutional differential diagnosis using 3D-Mac pulse diagnosis devices is 46.0% by now. Improvements in measuring pulse are required to achieve more accurate result and be used for diagnosis of Sasang constitution. Compensating B.M.I. among Sasang constitutional groups and separating constitutional pulse factors from acquired characteristics are also needed in further study.

Computerized pulse diagnosis system (컴퓨터 맥진시스템)

  • Lee, Ho-Jae;Huh, Woong
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.81-90
    • /
    • 1996
  • In this paper, we implemented a computerized pulse diagnosis system for the developement of pulse diagnosis algorithms and the generalization of the pulse diagnosis. The system consists of the hardware and software. The hardware detects pulse waves and inputs the waves into the computer system, while the software not only manages and analyzes the input pulse wave data but also privides the database. In order to clinically test the developed pulse diagnosis system, we applied the carotid-radial pulse diagnosis algorithm to the system. As the results, it is found that the genralizatio of the pulse diagnosis is possible.

  • PDF

A Case Study of Six Sigma Project for Improving method of measuring pulse wave (6시그마 기법을 통한 안정된 맥파측정 프로세스 설계)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.85-92
    • /
    • 2006
  • Pulse is one of the basic diagnostic information of TKM(Traditional Korean Medicine). To quantify and standardize pulse diagnosis, we had collected an amount of clinical data from May 2005 by using newly developed pulse analyzer. But there were many noises in pulse wave according to measuring method, environment, operator and condition of patient. So some data can’t be included for analyzing diagnosis. To reduce noises from measuring pulse and to collect reliable pulse wave data, we made the process map of measuring method and applied six sigma project. With this we can improved the method of measuring pulse wave in collecting clinical data. The project follows a disciplined process of five macro phases: define, measure, analyze, improve and control (DMAIC). A process map and C-E diagram are used to identify process input and output variables. The major input variables are selected by using C&E matrix, and process map is developed by analyzing input variables. And the optimum process conditions are going to be controled to avoid in increasing loss of collecting pulse wave data.

  • PDF

Analysing of pulse wave parameter and typical pulse pattern for diagnosis in floating and sinking pulses (${\cdot}$ 침맥 진단에 유용한 맥상 파라메터 및 대표맥상 분석)

  • Lee, Yu-Jung;Lee, Jeon;Choi, Eun-Ji;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.93-101
    • /
    • 2006
  • Pulse feeling is one of the most important diagnosis method in Oriental medicine. But it is not easy to make an objective and standardized diagnosis. In this study, we found how to quantify diagnosis. Specially dally the high practicality in clinic, we search some parameters especially well-related to floating and sinking pulse by statistic analysis. By extension, we find the pulse patterns of the floating and sinking pulse. We choose 15 subjects diagnosed as floating pulse and 15 subjects diagnosed as sinking pulse by oriental doctors. And their pulse signals were acquired by Pulse analyzer which has piezoresistive pressure sensor. For the quantification of the floating and sinking pulse, at first, we examined the parameters which were highly correlated with oriental doctor's diagnosis. And then we derived pulse patterns of the floating-sinking pulse from preprocessed signal and its ensemble average. We also looked trend variation (PH-Curve) between contact and pulse pressure. As a result, statistically there is the biggest difference between contact pressure, the maximum pulse pressure, diastolic area (Ad) and floating and sinking data. Through the PH-Curve, which represented the relationship between contact and pulse pressure, we could divide the floating and sinking pulse clearly. As a basic research of pulse diagnosis algorithm, we can contribute to select essential parameters in diagnosis algorithm And using these diagnosis method, we expect to find typical pulse patterns and some useful parameters about other pulses like slow/rapid, large/fine pulse and so on. We hope that this study will contribute pulse objectification.

  • PDF

Design of Digital Systems for Web -based Pulse Diagnosis Database

  • Lee, Junyoung;Lee, Sungjae;Lee, Myoungho;Kim, Jeonghoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.181.4-181
    • /
    • 2001
  • In this study, we have developed the digital hardware system which performs signal processing necessary for the filtering to eliminate noises by inputting pulse wave signals from the sensor group. With a view to obtain clinically effective information, we analyzed structural elements of pulse waveform and, thus, conducted a systematic classification. What is more, this study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse ...

  • PDF

Development of Clinical Protocol on the Correlation Between Disease Cause Pattern Identification and Pulse Wave Variables (병인변증과 요골동맥 맥상파의 특성 파악을 위한 탐색적 관찰 연구 : 임상시험 프로토콜 개발)

  • Kim, Jihye;Yu, Hana;Ku, Boncho;Kim, Hyunho;Kim, Jongyeol;Jeon, Youngju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.662-667
    • /
    • 2014
  • The purpose of this clinical study is to develop structured clinical trial protocol and guideline for improvement of safety, useful and effective of pulse diagnosis devices. As a first step, papers on pulse diagnosis and pulse diagnosis devices from 2001 and 2013 were systematically reviewed. In the next step, we have collected the opinions from the specialists, companies, and statistician in pulse diagnosis to evaluate the current condition, the state and problem of domestic clinical trial cases of pulse diagnosis device. And we have to created protocol and case report form (CRF) in regards to site condition and characteristics of pulse diagnosis devices, and showed the guideline of eligibility criteria, operation process, investigation items, evaluation items and so on. This clinical protocol will become a basic information for a researcher in designing or performing a clinical study of pulse diagnosis devices, and be used as a useful material during acquisition of good clinical data. Furthermore, we hope to enhance the invigoration of pulse diagnosis clinical trials and the performance improvement of pulse diagnosis devices.

A Study on the Research Demands for the Pulse Analyzer (맥진기 연구개발에 대한 수요조사)

  • Kim, Gyeong-Cheol;Kim, Jong-Hwan;Shin, Woo-Jin;Lee, Hai-Woong;Kang, Hee-Jung
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.29-40
    • /
    • 2009
  • The demand of research for the development of pulse meter and analyzer by the examination questionnaire made from repeated preliminary investigations. Which was presented in the exhibition KIMES 2008, it's has been proved to be practical. 159 people(oriental medical doctor) sent in the question papers and selected the double answers in the relevant question. At the time of the development of the pulse meter and analyzer, we put the investigation for oriental medical doctor's demands in practice and found the following results. The development of the pulse analyzer is getting more important for modernization of oriental medicine. The purpose of this study was to find out the research needs for the pulse analyzer considering the practical use in the oriental medical clinics. A survey was conducted at the KIMES 2008 exhibition with a set of questionnaires. We collected the data from 159 oriental medical doctors who attended the exhibition, and we found following results. The more oriental doctors did not think the diagnostic devices were important in their clinical practices. Most responders preferred to use the Chon-Kwan-Cheok pulse diagnosis. To find out the mechanism of the pulse diagnosis and to standardize it, the clinical data base containing the results of the pulse diagnosis and the patten discrimination of each patient should be established. In conclusion, the researches on the standardization of Chon-Kwan-Chuk pulse diagnosis including the measurement techniques and the pulse-pattern correlations are very important for developing the pulse analyzer.

  • PDF

A clinical study of atopic dermatitis patients as measured by Pulse diagnostic apparatus (맥진기(脈診器)를 이용한 아토피 피부염 환자의 임상적 고찰)

  • Shin, Yoon-Jin;Kim, Yoon-Bum;Yoon, Sang-Heub
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2008
  • Objective : The quantification of pulse diagnosis is an important subject utilizing as a modernization of Oriental medical diagnosis and as a basic data for collaborative access between East and West Medicine. This study was to observe the tendency of pulse diagnosis in atopic dermatitis patients as measured by pulse diagnostic apparatus. Methods : We did pulse diagnostic test about 11 new outpatients who had visited the department of ophthalmology, otolaryngology, dermatology in Kyunghee oriental medical center from March 1, 2007 to October 31, 2007 and had atopic dermatitis. Results : The results were as follows. 1. Among the 11 outpatients, the total number of male patients were 5 and female patients were 6, and the age distribution, the most frequently visited age groups were 10-19 years old and 20-29 years old(each 4 patients). 2. The most common period of onset to first examination were 3 years${\leq}$ (7 patients). 3. There were 8 patients who had emphasized T-wave. 4. There were 7 patients who had repeated pulse wave pattern. Conclusion : In 11 cases who had atopic dermatitis, 8 patients had emphasized T-wave and 7 patients had repeated pulse wave pattern.

  • PDF

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF