• Title/Summary/Keyword: Pulse wave

Search Result 1,037, Processing Time 0.035 seconds

The Correlation analysis of Hydrotherapy and pulse wave velocity in patients with sequelae of CVA (중풍후유증 환자에 있어서 맥파전달속도와 초음파 족욕에 따른 상관관계에 관한 임상적 연구)

  • Yun, Dae-Chul;Kim, Hee-Taek;Ryu, Ju-Hyun;Choi, Jong-Min
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.1
    • /
    • pp.135-144
    • /
    • 2006
  • Objective : The purpose of this study was to know the clinical effects of hydrotherapy based Ultrasonic spa using SoPung-Tang on pulse wave velocity in patients with sequelae of CVA. Methods : PWV(Pulse wave velocity), Bio Chemistry, Hematology, Blood Pressure were investigated in 20 patients(Experimental group 13, Control group 7) who have been in Semyung Oriental medicine hospital from December 2005 to February 2006. Results : 1. In experimental group, Rt PWV diminished 4.8%, Lt PWV 5.1%. 2. In control group, Rt PWV diminished 3.3%, Lt PWV 1.8%. Conclusion : Hydrotherapy based Ultrasonic spa using SoPung-Tang showed useful effects in patients with sequelae of CVA.

  • PDF

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Gabor Pulse-Based Matching Pursuit Algorithm : Applications in Waveguide Damage Detection (가보 펄스 기반 정합추적 알고리즘 : 웨이브가이드 결함진단에서의 응용)

  • 선경호;홍진철;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.969-974
    • /
    • 2004
  • Although guided-waves are very efficient for long-range nondestructive damage inspection, it is not easy to extract meaningful pulses of small magnitude out of noisy signals. The ultimate goal of this research is to develop an efficient signal processing technique for the current guided-wave technology. The specific contribution of this investigation towards achieving this goal, a two-stage Gabor pulse-based matching pursuit algorithm is proposed : rough approximations with a set for predetermined parameters characterizing the Gabor pulse and fine adjustments of the parameters by optimization. The parameters estimated from the measured signal are then used to assess not only the location but also the size of a crack existing in a rod. To validate the effectiveness of the proposed method, the longitudinal wave-based damage detection in rods is considered. To estimate the crack size, Love's theory for the dispersion of longitudinal waves is employed.

  • PDF

The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG (촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yun, Jung-Mi;Jeon, Seong-Ha
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF

A Study on Factors Influencing P-wave Velocity of Concrete (콘크리트의 P파 속도에 영향을 주는 인자에 관한 연구)

  • 이광명;이회근;김동수;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.725-730
    • /
    • 1998
  • Recently, non-destructive tests are getting popular in evaluating concrete properties without braking specimens. Among several NDT methods, P-wave velocity measurement technique has been widely used to evaluate the stiffness and strength of concrete. The purpose of this study is to investigate factors influencing P-wave velocity measured by impact-resonant method and ultrasonic pulse velocity method, such as moisture content of concrete, existence and size of coarse aggregates, sensor and sampling rate. Test results show that rod-wave velocity measured by impact-resonant method and ultrasonic pulse velocity are significantly affected by the moisture content of concrete, i.e., the lower moisture content, the lower velocity. Moisture content influences rod-wave velocity stronger than ultrasonic pulse velocity. Rod-wave velocity is faster in concrete than in mortar and is also faster in concrete containing small size aggregates. Sensor and sampling rate have little influence on velocity.

  • PDF

Study of the relationship between manual pulse diagnosis and machinery measurement on QiguㆍInyoung comparison pulse diagnosis (기구인영비교맥법에 대한 수지맥진과 기기측정치의 상관성 연구)

  • Jun Yong Seck;Chae Wo Seck;Cho Myung Rae;So Cheal Ho;Choi Chan Hun;Jang Kyeang Sean
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.1
    • /
    • pp.201-208
    • /
    • 2002
  • The measurement parameter of QiguㆍInyoung pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Qigu and Inyoung. We have estimated the relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis by means of quantifying pulse peak and Inyoung/Qigu index. The results can be summarized as follows : When standardizing manual pulse diagnosis measurement was standardized, Inyoung index of machinery measurement was more significantly correlative with the index of manual pulse diagnosis than Qigu index of machinery measurement. The ratio of Inyoung/Qigu magnitude with machinery measurement was doser to manual pulse diagnosis than that of Qigu and Inyoung pulse magnitude measured separately. A linear proportion relationship was found between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis. It was necessary to adjust the output signal of pulse in order to estimate the exact relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis.

Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper (Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증)

  • Kim, Y.H.;Woo, M.A.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

Study on the Discrimination of Constitution Using Pulse Wave (맥상파를 이용한 체질 판별방법에 관한 연구)

  • Shin, Sang-Hoon;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1403-1409
    • /
    • 2008
  • The purpose of this study is to develop the systematic process on the discrimination of Sasang constitution with the pulse diagnosis apparatus. The pulse waves were acquired at the right and the left Guan point with 1420 people who were apparently healthy. In order to minimize the effect of aging on the shape of pulse wave, the age groups of 30s, 40s, and 50s were used. Taeum group was the best to classify, Soyang group was the worst. With the same group size, the sensitivity of Soyang group was increased. Input variables were selected with the consideration of the floating-sink ratio, tests of equality of group means, multiple comparison, multicollinearity, and structure matrix. To increase the sensitivity of Soyang, the variables which could tell the difference between Soyang and Soeum were selected.

The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI (BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF

Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구)

  • Kim, Young-Ju;Bang, Sang-Seok;Lee, Chae-Han;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.