• Title/Summary/Keyword: Pulse wave

Search Result 1,035, Processing Time 0.032 seconds

Remote Monitoring of Patients and Emergency Notification System for U-Healthcare

  • Lee, Jun;Jang, Hyun-Se;Yang, Tae-Kyu;Seo, Yong-Ho
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • This study proposes a remote monitoring of patients and emergency notification system with a camera and pulse wave sensor for U-Healthcare. The proposed system is a server client model based U-Healthcare system which consists of wireless clients that have micro-controller, embedded-board for patient status monitoring and a remote management server. The remote management server observes the change of pulse wave data individually in real-time sent from the clients that is to be remote-monitored based on the pulse wave data stored by users and divides them into caution section and emergency section. When the pulse wave data of a user enters an emergency situation, the administrator can make a decision based on the real-time image information and pulse rate variability. When the status of the monitored patient enters the emergency section, the proposed U-healthcare system notifies the administrator and relevant institutions. An experiment was conducted to demonstrate the pulse wave recognition of the proposed system.

A Study on the Pulse Wave Parameter in Post Mastectomy Women (유방암 절제술 여성의 맥파요인 연구)

  • Kim, Gyeong-Cheol;Park, Sang-Wook;Kim, Yi-Soon;Kim, Yun-Hee
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.101-112
    • /
    • 2011
  • Objectives : This study was done to investigate the degree of the pulse wave parameter of post-mastectomy women and to identify the relationships between each of them. Methods : Data were obtained from public health center in Busan Metropolitan city. Participants were 82 post-mastectomy women aged 31-82. the data collection was from Oct, 1, 2010 to Oct, 31, 2010. the data were analyzed with descriptive statistics, one-way ANOVA, Duncan test. A p-value less than .05 was considered significant by 2-tailed test. All statistical analyses were performed with SPSS/Win(ver 12.0). Results : As for the difference in the pulse wave by the general characteristics. The pulse energy was showed highly in the order of Chon, Quan and Chuk of left and right pulse respectively. In the pulse energy of left Quan and right Chon, the case of both mastectomy was showed highly and in the pulse energy of left Chuk, the case of right mastectomy was showed highly. Left and right pulse energy of menopause female were significantly higher than normal range except left Chon and Chuk. In h1, h2, h4, h5, t1, t2, AP and Aw, the pulse energy of left Chon was showed the largest significantly. In As, the pulse energy of right Chon was showed the smallest and in Ad, right Chuk was showed the largest. In RAI, right and left Chuk was showed the highest respectively. Conclusions : From these result, we can see that there are relation between women's age, area of operation breast and menopause after mastectomy in pulse wave. The result of this study will become basic data necessary for the Oriental Medicine treatment to reduce or prevent women's functional difficulties, symptomatology after mastectomy.

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

A clinical study of atopic dermatitis patients as measured by Pulse diagnostic apparatus (맥진기(脈診器)를 이용한 아토피 피부염 환자의 임상적 고찰)

  • Shin, Yoon-Jin;Kim, Yoon-Bum;Yoon, Sang-Heub
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2008
  • Objective : The quantification of pulse diagnosis is an important subject utilizing as a modernization of Oriental medical diagnosis and as a basic data for collaborative access between East and West Medicine. This study was to observe the tendency of pulse diagnosis in atopic dermatitis patients as measured by pulse diagnostic apparatus. Methods : We did pulse diagnostic test about 11 new outpatients who had visited the department of ophthalmology, otolaryngology, dermatology in Kyunghee oriental medical center from March 1, 2007 to October 31, 2007 and had atopic dermatitis. Results : The results were as follows. 1. Among the 11 outpatients, the total number of male patients were 5 and female patients were 6, and the age distribution, the most frequently visited age groups were 10-19 years old and 20-29 years old(each 4 patients). 2. The most common period of onset to first examination were 3 years${\leq}$ (7 patients). 3. There were 8 patients who had emphasized T-wave. 4. There were 7 patients who had repeated pulse wave pattern. Conclusion : In 11 cases who had atopic dermatitis, 8 patients had emphasized T-wave and 7 patients had repeated pulse wave pattern.

  • PDF

Numerical Investigation on detonation combustion waves of hydrogen-air mixture in pulse detonation combustor with blockage

  • Pinku Debnath;K.M. Pandey
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.3
    • /
    • pp.203-222
    • /
    • 2023
  • The detonation combustion is a supersonic combustion process follows on shock wave oscillations in detonation tube. In this paper numerical studies are carried out combined effect of blockage ratio and spacing of obstacle on detonation wave propagation of hydrogen-air mixture in pulse detonation combustor. The deflagration to detonation transition of stoichiometric (ϕ=1)fuel-air mixture in channel has been analyzed for effect of blockage ratio (BR)=0.39, 0.51, 0.59, 0.71 with spacing of 2D and 3D. The reactive Navier-Stokes equation is used to solve the detonation wave propagation mechanism in Ansys Fluent platform. The result shows that fully developed detonation wave initiation regime is observed near smaller vortex generator ratio of BR=0.39 inside the combustor. The turbulent rate of reaction has also a great significance role for shock wave structure. However, vortices of rapid detonation wave are appears near thin boundary layer of each obstacle. Finally, detonation combustor demonstrates the superiority of pressure gain combustor with turbulent rate of reaction of 0.6 kg mol/m3 -s inside the detonation tube with obstacle spacing of 12 cm, this blockage enhanced the turbulence intensity and propulsive thrust. The successful detonation wave propagation speed is achieved in shortest possible time of 0.031s with a significance magnitude of 2349 m/s, which is higher than Chapman-Jouguet (C-J) velocity of 1848 m/s. Furthermore, stronger propulsive thrust force of 36.82 N is generated in pulse time of 0.031s.

Study on the Verification of Healing Effect through Brain and Pulse Wave Analyses before and after Forest Walking (산림 산책 전후 뇌파 및 맥파 분석을 통한 치유효과 검증 연구)

  • Min-Su Kim;Jung-Hun Yeum
    • Journal of Environmental Science International
    • /
    • v.33 no.4
    • /
    • pp.249-256
    • /
    • 2024
  • This study aimed to verify the healing effect through brain and pulse wave analyses before and after a forest walk to the university students. Bio-signals of brain and pulse waves were measured using Omnifit Mindcare. After analyzing four brain wave items such as concentration and four pulse wave items such as heart health, it is identified that the stress level of university students was higher than that of the general public, and the brain stress level was approached to the normal range for 19 people with clear improvement. For pulse waves, a statistically significant decrease in sympathetic nerve activity (%) was confirmed. Although the slight fluctuations within the normal range were caused by short term and individual differences, it showed that the forest walking is partially effect on the relieving stress.

The Study on the Feature Point Recognition and Classification of Radial Pulse (맥파의 특징점 인식과 파형의 분류에 관한 연구)

  • 길세기;김낙환;이상민;박승환;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.555-558
    • /
    • 1999
  • In this paper, Ire present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also we specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm. then we classify the shape of radial pulse by existence and position of feature points.

  • PDF

A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men (한국인 성인 남성의 체질별 맥상 특성에 관한 연구)

  • Kim, Ho-Seok;Ryu, Hyun-Hee;Lee, Si-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile (압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가)

  • Kim, Jung-Chae;Jee, Sun-Ha;Yoo, Sun-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.