• Title/Summary/Keyword: Pulse therapy

Search Result 326, Processing Time 0.029 seconds

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

Clinical Assessment of Warm Acupuncture Therapy System Using HF Time-varying Magnetic Field (고주파 자기장을 이용한 온침 치료시스템의 임상 평가)

  • Lee, Su-Yong;Byeon, Sang-Jun;Choi, Ye-Bin;Kim, Jin-Ju;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • Objectives : The aim of this paper is to develop acupuncture needle heating system by utilizing the new method which uses high frequency(HF) time-varying magnetic field. Also, it is possible to make an assessment for reliability and clinical significance of the system. Methods : We designed the system with solenoid coils for generation of HF time-varying magnetic field that oscillates at 150 kHz. Acupuncture needles are quickly magnetized and heated by 150 kHz. We assessed clinical significance of system, such as body temperature, pressure pulse waveform. Results : Temperature of acupuncture needle increased up to 60 degree. In the result for clinical significance of system, in case of manual acupuncture stimulation(MAS), body temperature change was $0.373^{\circ}C{\pm}0.224$(p<0.05), rate of pulse energy change increased about 7.6%. In case of warm acupuncture stimulation(WAS), body temperature change was $0.645^{\circ}C{\pm}0.281$(p<0.05), rate of pulse energy change remarkably increased about 35.9%. Conclusions : We confirm that the system is able to be applied clinically to various warm acupuncture needle therapy in the area of oriental medicine.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Cervical Cementum (Nd:YAG 레이저조사가 치경부 백악질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Choi, Bok;Lee, Jeong-Yeon;Shin, Keum-back
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.4
    • /
    • pp.415-425
    • /
    • 2000
  • In order to obtain the basic data concerning the optimal lasing conditions in using Nd:YAG laser as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum, the author selected 36 human teeth having no cervical abrasion and caries (; 12 anteriors, 12 premolars. 12 molars) extracted due to periodontal diseases, and divided them into 4 groups as Group I, II, III and IV (; each group of 3 anteriors, 3 premolars, 3 molars), and prepared a cementum specimen with thickness of $1.0mm{\pm}0.2mm$ sectioned longitudinally at the middle of mesio-distal thickness (; Group I) or horizontally at 1mm-2mm below the cemento-enamel junction (; Group II, III, IV) from each tooth of each group by low speed diamond wheel saw, and treated them with 0.5 M ethylene diamine tetraacetic acid (; EDTA, pH=7.4) for 2 minutes for elimination of remnants during tooth-sectioning. And the author applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (; wavelength 1064nm. pulse duration $120{\mu}sec$, fiber diameter $320{{\mu}m}$) to cementum surfaces in triplicates of one experiment under the following lasing conditions: 1. stationary mode of fiber in contact to cementum surfaces without air-spray (; Group I )/with air-spray (; Group II), 2. unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec without air-spray (; Group III)/with air-spray (; Group IV), 3. energy per pulse (mJ/pulse) [; energy density ($J/cm^{2}$)] in order of 1.0W/10Hz (100J/pulse); $124J/cm^{2}$, 0.5W/10Hz (50mJ/pulse); $62J/cm^{2}$, 0.4W/10Hz (40mJ/pulse); $50J/cm^{2}$, 0.3W/10Hz (30mJ/pulse); $37J/cm^{2}$, 4. exposure time of 1 second. And the author applied the platinum coating on surfaces of cementum specimens, and evaluated the characteristics of ultrastructural change on surfaces of cementum using the scanning electron microscopy. In general the ultrastructural loss of cervical cementum irradiated under the same lasing condition of laser energy density occurred least in specimens of Group IV. And especially, the ultrastructural loss of cervical cementum irradiated under the laser energy density of $37J/cm^{2}$ almost did not occur in specimens of Group IV. Therefore, it is considered that the pulsed Nd:YAG laser should be applied with the lasing conditions of unidirectional moving mode of fiber in contact to cementum surfaces under speed of 3mm-4mm/sec with air-spray and of laser energy density within $37J/cm^{2}$ as an adjunctive modality of periodontal therapy of root planing without irreversible structural deterioration of cervical cementum.

  • PDF

The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer (광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발)

  • 임현수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.319-328
    • /
    • 2003
  • The purpose of this paper is to develop a medical laser system using the semiconductor diode laser in order to photodynamic cancel therapy as a light source. The ideal light source for photodynamic therapy would be a homogeneous nondiverging light with variable spot size and specific wavelength with stability. After due consideration in this point, in this paper, we used a diode laser resonator of 635nm wavelength. The development laser system have a statistical laser out beam with accuracy control using the constant current control of method and clinic-friendly with compact. In order to protect the diode resonator from the over-current, the rush-current and electrical fault, we specially designed. The most importance therapeutic factor are the radiation mode for cancer therapy. So we developed the radiation mode of CW(Continuous Wave), long pulse, short pulse, and burst pulse and can adjust the exposure time from several milli-second to several minute. The experimental result shows that laser beam power was increased linear from 10mW to 300mW according to the increasing input current and the increasing exposure time. The developed new compact diode laser system have a stability of output power and specific wavelength with easy control and transportable for many applications of PDT.

The Effect of Ultrasound on Epidermal Growth Factor Expression in Rat Wound Tissue (초음파가 창상조직내 표피성장인자의 발현에 미치는 영향)

  • Nam Ki-Won;Ku Hyun-Mo;Kim Suk-Bum;Lee Sun-Min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.107-115
    • /
    • 2002
  • This study was performed to investigate the effect of ultrasound irradiation on epidermal growth factor(EGF) expression in rat wound tissue. Skin wounds were created below 5mm to both sides of scapular inferior angle. The right wound was used experimental side and left was used control side. Ultrasound was irradiated pulse rate $20\%$, frequency 1MHz, intensity $0.5W/cm^2$ for 5 minutes during 3days. After sonication during 3 days, rats were sacrified. The expression of epidermal growth factor evaluated immunohistochemistry on mouse anti-EGF. In the control side, a little expression of EGF was observed at epidermis and dermis. In the experimental side, A strong immunostaining was seen at epidermis and dermis. This study suggests that ultrasound irradiation is effective on EGF expression in wound tissue.

  • PDF

The Effects of Relaxation Therapy on Pain and Anxiety in Spinal Anesthesia Surgery Patients (척추마취 수술환자의 불안감소를 위한 이완요법 적용 효과)

  • Moon, Hyeun-Sook;Lee, Hyang-Yeon;Lee, Ji-A
    • Journal of East-West Nursing Research
    • /
    • v.15 no.1
    • /
    • pp.54-62
    • /
    • 2009
  • Purpose: The purpose of this study was to examine the effects of relaxation therapy to reduce anxiety level among spinal anesthesia surgery patients. Methods: The study employed a quasi-experimental pre-and-posttest design with nonequivalent control group. The experimental group was provided with the 15-min muscle relaxation therapy on the day before the surgery and an hour before the spinal anesthesia. Data were collected from 44 patients (22 in experimental and 22 in control group) who were planned to have spinal anesthesia surgery from an orthopedic surgery department at a general hospital in Seoul from January 13 to March 21, 2006. Results: The experimental group reported lower level of state anxiety after the surgery (23.18 vs. 33.64) than did control group but was not statistically significant. There were no significant differences in blood pressure or pulse rate between experimental and control groups after surgery. Conclusions: The further research should be conducted to polish the muscle relaxation therapy for various types of patients and to create more comfortable environment setting for application of the therapy. The muscle relaxation therapy may be a convenient and useful nursing intervention to reduce anxiety among spinal anesthesia surgery patients if more studies prove its effectiveness.

Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation (신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화)

  • Choi, Soo-Hee;Oh, Myung-Hwa;Kim, Tae-Youl;Jeong, Jin-Gyu
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Effects of Strengthening Exercise Program on the Improvement of Balance in the Elderly (근력강화 운동프로그램이 노인의 균형증진에 미치는 영향)

  • Kim Han-Soo;Kim Sang-Soo;Lee Dong-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.45-59
    • /
    • 2002
  • The purpose of this study was to investigate the effects of strengthening exercise program on the improvement of balance in the elderly Subjects were forty members living in Daegu (20 males, 20 females), between 65 and 81 years of age. The subjects were divided into two groups; an experimental group and a control group, and each group included 10 males and 10 females. The subjects for the experimental group were participated in the strengthening exercise program for 8 weeks, between April 2001 and June 2001 The results of this study were as follows: 1. General characteristics statistically significantly affecting for CTSIB were mental status; weight, height, vision, systolic blood pressure, diastolic blood pressure, pulse rate, mental status, obesity and thigh BMD were BBT; age, weight, height, vision, blood pressure systolic, blood pressure diastolic, blood pulse rate, mental status, obesity, spine BMD and thigh BMD were for OLST. 2. After the exercise program, there was no significant difference in the balance ability between the experimental group and the control group in CTSIB. However, there was a significant difference in OLSTR on the hard (p<0.05) and soft (p<0.05) surface with open eyes condition between the experimental group and the control group. In the case of OLSTL, there was a significant difference on the hard surface with open eyes condition (p<0.05), and on the soft surface with open eyes condition (p<0.05) and closed eyes condition (p<0.05) between the experimental group and the control group. There was no significant difference in the balance ability between the experimental group and the control group in BBT.

  • PDF

The Literature Study on Jung point venesection therapy (정혈(井穴) 자락요법(刺絡療法)에 관(關)한 문헌고찰(文獻考察))

  • Kim, Yoon-hee;Lee, Hyun;Lee, Byung-ryul
    • Journal of Haehwa Medicine
    • /
    • v.10 no.1
    • /
    • pp.237-245
    • /
    • 2001
  • I have come to next conclusions in consequnce of documentary study about medical books of many generations regarding Jung point venesection therapy. 1. Jung point is significant as the beginning of pulse energy flow on meridian, the origin of all meridional pulse energy being located at extrimity terminal, confluence of three yin and three yang, and emergent treatment point. 2. Jung point venesection therapy was much used for the first-aid treatment for acute and thermic disease, and that is the combination of the meaning as of restoration from death and emergent treatment of Jung point and function of openning of orifice, leakage of fever, circulation of blood, remove of edema of venesection therapy. 3. It is very much used for emergency case, five sensory organ disease and CVA, heating shock and so on. Besides that digestive disease, cough, fever with cold, childhood disease, cardiac ache, thoracic disease, numbness of digitus terminal, mental disorder follow that in order. 4. Sosang, Jung point of Arm Greater Yin Lung meridian, is very much used for five sensory organ disease. Sosang is for orbital disease, sangyang for auditory disease, sosang for nasal disease, and sosnag for introitus-throat disease. 5. Ten Jung point is most used for first-aid diseases of CVA, heating shock. 6. Ten Jung point is most used for digestive disease of stomach ache, vomiting, diarrhea, intestinal convulsion. 7. Ten Jung point is most used for cold disease of cough, fever, malaria. 8. Ten Jung point, sosang, kwanchung are much used for childhood disease of acute convulsion and fever. 9. Among Jung point, sosang is most used, 34 times. Next there are Ten Jung point, kwanchung, sangyang, sotaek, jungchung, unbaek, taedon in order. In the order of frequency in use, arm channel is more used than leg channel.

  • PDF