• 제목/요약/키워드: Pulse test

Search Result 1,181, Processing Time 0.024 seconds

Experimental Study on Laser-driven Miniflyer for Description of Space Debris with High-speed (빠른 속도의 우주먼지 모사를 위한 레이저기반의 입자가속에 관한 실험적 연구)

  • Baek, Won-Kye;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.120-126
    • /
    • 2013
  • Increasing numbers of space debris around the earth now pose a major threat to satellites as their impact velocity may reach up to several km/s. We use a pulse laser to accelerate a miniflyer for mimicking the space debris. The multi-layer coat on the confined medium is known to promote a higher acceleration. However, it requires some special techniques which take somewhat long time and cost to coat. Instead, we devised a simple concept to coat by the black lacquer paint on a flyer. It shows improvement in the flyer velocity by 1.5-2 times the uncoated, and the resulting velocity reached 1.42km/s with Nd:YAG laser energy under 1.4 joules. The resulting velocity is suitable for satellite vulnerability test for debris impact in the geostationary orbit.

Electrical and optical characeristics of ZnS:Mn thin-film electroluminescent(TFEL) devices grown by atomic layer epitaxy (Atomic layer epitaxy(ALE) 방법으로 제작된 ZnS:Mn 박막전계발광소자의 전기, 광학적 특성)

  • 이순석;윤선진;임성규
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.52-59
    • /
    • 1998
  • The ZnS:Mn thin film electroluminescent(TFEL) devices fabricated by ALE system were investigated. Yellow-orange light emission was observed when the applied voltage exceeded 134 V and luminance increased sharply as the applied voltage increased. Luminance of 568 Cd/c $m^{2}$ was obtained under 1 KHz sinusoidal voltage wave application at the peak applied voltage of 230 V. The peak wavelength of the emissionwas 577 nm. The C-V, Q-V, $Q_{t}$ - $F_{p}$ , L- $Q_{cond}$, and V- $Q_{pol}$ have been measured under theapplication of the trapezoidal wave with its pulse width varying 0 to 75 .mu.sec. The phoshor and the insulator capacitance of the TFEL device under test were 24.3 nF/c $m^{2}$ and 9 nF/c $m^{2}$, respectively. It was observed that the threshold voltage changed from 137V to 100V as the pulse width varied from 0 to 75 .mu.sec. The L- $Q_{cond}$ characteristics showed that the light emission increased in proportion to the $Q_{cond}$. The luminance increased from 386 Cd/ $m^{2}$ to 607 Cd/ $m^{2}$ when the $Q^{+}$$_{cond}$ increased from 1.3 .mu.C/c $m^{2}$ to 2.3 .mu.C/c $m^{2}$. The V- $Q_{pol}$ characteristics showed that the V was inversely proportional to $Q_{pol}$./. th/ was inversely proportional to $Q_{pol}$./. pol/./.

  • PDF

A Study about Correlation between Hot Flush and Pulse Wave Velocity(PWV)/Ankle-Brachial Index(ABI) in the Climacteric Women (갱년기 여성의 안면홍조와 맥파 전달 속도(PWV) 및 상완 발목 지수(ABI)의 상관성에 관한 연구)

  • Kim, Eun-Gyung;Hwang, Deok-Sang;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Jin-Moo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.1
    • /
    • pp.53-64
    • /
    • 2010
  • Purpose: This study was performed to observe the correlation between Hot flush and pulse wave velocity(PWV), ankle brachial index(ABI) in the Climacteric women. Methods: We studied 63 climacteric women visiting OO hospital from 8th January 2007 to 22nd April 2009. The subjects were categorized in two groups, the hot flush group(37) and normal group(26). For the study, the subjects were selected by excluding the patients who receive treatment affect hot flush or have disease affect arterial states. We assessed PWV and ABI of two groups by Oscillometric method using VS-1000(Form PWV/ABI; Fukuda Denshi, Co., Ltd., Japan). From these results, we studied the correlation between hot flush and PWV/ABI by Wilcoxon Mann Whitney Test. Results: 1. It is shown that hot flush group was no significant correlation with normal group. There is no significant factor among R-PWV, L-PWV, R-ABI, L-ABI. However, L-ABI have shown relatively higher correlation with comparison to the other factors.(p-value<0.05) 2. R-PWV, L-PWV significantly increased in menopause group than in premenopause group though there is no relation to the hot flush. (p-value<0.01) Conclusion: Though the results showed no correlations between Hot flush and PWV/ABI in the Climacteric women, L-ABI showed relatively higher correlation with hot flush than others. R-PWV, L-PWV showed significant correlation between premenopause and menopause.

Butt Weldability of Shipbuilding Steel AH36 Using Laser-Arc Hybrid Welding (조선용 강판 AH36의 레이저-아크 하이브리드 용접시 맞대기 용접 특성)

  • Kim, Jong Do;Myoung, Gi Hoon;Suh, Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.901-906
    • /
    • 2016
  • The purpose of this study is to improve productivity by implementing one-pass full penetration welding using laser-arc hybrid welding for AH36. On increasing the thickness of the plate, a higher power of laser and arc was required to obtain full penetration. However, increasing the power of heat source caused undercut defects at both ends of the bead. This undercut was prevented by controlling the parameters of welding voltage and pulse correction. Hardness measurement and tensile test were conducted to apprehend the mechanical properties of weld. Also, by carrying out the microstructure observation for laser and arc regions, microstructural properties were understood.

Effect of Desexualization Care guided by Dramaturgical Interaction on Women's Embarrassment during Cervical Cancer Screening (연극학적 상호작용에 의한 탈성화 간호가 자궁경부 세포진 수검 여성의 당혹감에 미치는 효과)

  • Cho, Eun-Jung;Chung, Bok-Yae;Koo, Tae-Bon
    • Women's Health Nursing
    • /
    • v.9 no.4
    • /
    • pp.351-358
    • /
    • 2003
  • Purpose: The aim of this study was to examine the effect of Desexualization Care guided by dramaturgical interaction on women's embarrassment during cervical cancer screening. Method: This study was carried out in a nonequivalent control group non-synchronized post-test only design. 62 women who had cervical cancer screening were' conveniently recruited from a university hospital health promotion center. Embarrassment was measured under four distinctive sub-dimensions by the method of self-reported questionnaire and blood pressure and pulse rates monitoring. The data of control group had a conventional pap smear were collected in advance and then those of experimental group were gathered after completing data collection in the control group. Women in experimental group were provided with a newly developed cervical cancer screening programme in which interdisciplinary team conducted dramaturgical interaction. Result: There was no significant difference in the scores of VAS between the two groups. The score of physiological response of Embarrassment Measurement Scale was significantly lower in experimental group than in the control group (p <.05), while no significant difference was found in cognitive-emotional, non-verbal and verbal behavioral responses between the two groups. There was also no significant difference in blood pressure and pulse rates between the two groups during cervical s creening. Conclus ion: Desexualization Care guided by dramaturgical interaction during cervical screening was found to have positive effect on physiological response of women's embarrassment. Further research for identifying other main variables which might have influenced on women's embarrassment is needed.

  • PDF

Resistive Switching Properties of Cr-Doped SrZrO3 Thin Film on Si Substrate (실리콘 기판위에서의 Cr-Doped SrZrO3 박막의 저항변화 특성)

  • Yang, Min-Kyu;Ko, Tae-Kuk;Park, Jae-Wan;Lee, Jeon-Kook
    • Korean Journal of Materials Research
    • /
    • v.20 no.5
    • /
    • pp.241-245
    • /
    • 2010
  • One of the weak points of the Cr-doped SZO is that until now, it has only been fabricated on perovskite substrates, whereas NiO-ReRAM devices have already been deposited on Si substrates. The fabrication of RAM devices on Si substrates is important for commercialization because conventional electronics are based mainly on silicon materials. Cr-doped ReRAM will find a wide range of applications in embedded systems or conventional memory device manufacturing processes if it can be fabricated on Si substrates. For application of the commercial memory device, Cr-doped $SrZrO_3$ perovskite thin films were deposited on a $SrRuO_3$ bottom electrode/Si(100)substrate using pulsed laser deposition. XRD peaks corresponding to the (112), (004) and (132) planes of both the SZO and SRO were observed with the highest intensity along the (112) direction. The positions of the SZO grains matched those of the SRO grains. A well-controlled interface between the $SrZrO_3$:Cr perovskite and the $SrRuO_3$ bottom electrode were fabricated, so that good resistive switching behavior was observed with an on/off ratio higher than $10^2$. A pulse test showed the switching behavior of the Pt/$SrZrO_3:Cr/SrRuO^3$ device under a pulse of 10 kHz for $10^4$ cycles. The resistive switching memory devices made of the Cr-doped $SrZrO_3$ thin films deposited on Si substrates are expected to be more compatible with conventional Si-based electronics.

The Surface Sidelobe Clutter and the False Alarm Probability of Target Detection for the HPRF Waveform of the Microwave Seeker (마이크로파 탐색기의 HPRF 파형에 대한 지표면 부엽클러터와 표적탐지 오류 확률)

  • Kim, Tae-Hyung;Yi, Jae-Woong;Byun, Young-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4C
    • /
    • pp.476-483
    • /
    • 2009
  • Tracking and detecting targets by the microwave seeker is affected by the clutter reflecting from the earth's surface. In order to detect retreating targets in look-down scenario, which appear in the sidelobe clutter (SLC) region, in the microwave seeker of high pulse repetition frequency (HPRF) mode, it is necessary to understand statistical characteristics of the surface SLC. Statistical analysis of SLC has been conducted for several kinds of the surface using data obtained by the captive flight test of the microwave seeker in the HPRF mode. The probability density function (PDF) fitting is conducted for several kinds and conditions of the surface. PDFs and PDF parameters, which best describe statistical distribution of the SLC power, are estimated. By using the estimated PDFs and PDF parameters, analyses for setting the target-detection thresholds, which give a desired level of target-detection false alarm probability, are made. These analysis materials for statistical characteristics of SLC power and the target-detection threshold can be used in various fields, such as development of a target-detection method, the constant false alarm rate processing.

A Development of Hourly Rainfall Simulation Technique Based on Bayesian MBLRP Model (Bayesian MBLRP 모형을 이용한 시간강수량 모의 기법 개발)

  • Kim, Jang Gyeong;Kwon, Hyun Han;Kim, Dong Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.821-831
    • /
    • 2014
  • Stochastic rainfall generators or stochastic simulation have been widely employed to generate synthetic rainfall sequences which can be used in hydrologic models as inputs. The calibration of Poisson cluster stochastic rainfall generator (e.g. Modified Bartlett-Lewis Rectangular Pulse, MBLRP) is seriously affected by local minima that is usually estimated from the local optimization algorithm. In this regard, global optimization techniques such as particle swarm optimization and shuffled complex evolution algorithm have been proposed to better estimate the parameters. Although the global search algorithm is designed to avoid the local minima, reliable parameter estimation of MBLRP model is not always feasible especially in a limited parameter space. In addition, uncertainty associated with parameters in the MBLRP rainfall generator has not been properly addressed yet. In this sense, this study aims to develop and test a Bayesian model based parameter estimation method for the MBLRP rainfall generator that allow us to derive the posterior distribution of the model parameters. It was found that the HBM based MBLRP model showed better performance in terms of reproducing rainfall statistic and underlying distribution of hourly rainfall series.

Modeling and Analysis of Cushioning Performance for Multi-layered Corrugated Structures

  • Park, Jong Min;Kim, Ghi Seok;Kwon, Soon Hong;Chung, Sung Won;Kwon, Soon Goo;Choi, Won Sik;Kim, Jong Soon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.221-231
    • /
    • 2016
  • Purpose: The objective of this study was to develop cushion curves models and analyze the cushioning performance of multi-layered corrugated structures (MLCS) using a method based on dynamic stress-energy relationship. Methods: Cushion tests were performed for developing cushion curve models under 12 combinations of test conditions: three different combinations of drop height, material thickness, and static stress for each of four levels of energy densities between 15 and $60kJ/m^3$. Results: Dynamic stress and energy density for MLCS followed an exponential relationship. Cushion curve models were developed as a function of drop height, material thickness, and static stress for different paperboards and flute types. Generally, the differences between the shock pulse (transmitted peak acceleration) and cushion curve (position and width of belly portion) for the first drop and the averaged second to fifth drop were greater than those for polymer-based cushioning materials. Accordingly, the loss of cushioning performance of MLCS was estimated to be greater than that of polymer-based cushioning materials with the increasing number of drops. The position of the belly of the cushion curve of MLCS tends to shift upward to the left with increasing drop height, and the belly portion became narrower. However, depending on material thickness, under identical conditions, the cushion curve of MLCS showed an opposite tendency. Conclusions: The results of this study can be useful for environment-friendly and optimal packaging design as shock and vibrations are the key factors in cushioning packaging design.

The Characteristics of Chalcogenide $Ge_1Se_1Te_2$ Thin Film for Nonvolatile Phase Change Memory Device (비휘발성 상변화메모리소자에 응용을 위한 칼코게나이드 $Ge_1Se_1Te_2$ 박막의 특성)

  • Lee, Jae-Min;Chung, Hong-Bay
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.297-301
    • /
    • 2006
  • In the present work, we investigate the characteristics of new composition material, chalcogenide $Ge_1Se_1Te_2$ material in order to overcome the problems of conventional PRAM devices. The Tc of $Ge_1Se_1Te_2$ bulk was measured $231.503^{\circ}C$ with DSC analysis. For static DC test mode, at low voltage, two different resistances are observed. depending on the crystalline state of the phase-change resistor. In the first sweep, the as-deposited amorphous $Ge_1Se_1Te_2$ showed very high resistance. However when it reached the threshold voltage(about 11.8 V), the electrical resistance of device was drastically reduced through the formation of an electrically conducting path. The phase transition between the low conductive amorphous state and the high conductive crystal]me state was caused by the set and reset pulses respectively which fed through electrical signal. Set pulse has 4.3 V. 200 ns. then sample resistance is $80\sim100{\Omega}$. Reset pulse has 8.6 V 80 ns, then the sample resistance is $50{\sim}100K{\Omega}$. For such high resistance ratio of $R_{reset}/R_{set}$, we can expect high sensing margin reading the recorded data. We have confirmed that phase change properties of $Ge_1Se_1Te_2$ materials are closely related with the structure through the experiment of self-heating layers.