• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.031 seconds

Power Quality Measurement for LED-based Green Energy Lighting Systems (LED 기반 그린에너지 조명시스템을 위한 전력품질 측정)

  • Yu, Hyung-Mo;Choi, Jin-Won;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.174-184
    • /
    • 2013
  • For the successful R&D and deployment of LED-based green energy lighting systems, the real-time power quality measurement of both various non-linear power signals including pulse waveform, spike waveform, etc and the undesired-signals including harmonics, sag, swell, etc is required. In this paper, we propose a low-cost power quality measurement (PQM) method for low- (60Hz-several KHz) to high-frequency (several tens KHz) power signals, which are generated by green-energy lighting systems, and implement a PQM testbed using TI TMS320F28335 MCU. The proposed algorithm is programmed using C in the CCS (Code Composer Studio) 3.3 environment and is verified using test signals generated by an arbitrary signal generator, NF-WF1974. In the implemented testbed, we can measure various non-linear current signals that LED SMPS generates, analyze harmonics by fast Fourier transform, and test sag, swell, and interruption using wavelet transform.

Transport of space charge between sub-pixels in AC-plasma cell discharge

  • Lee, S.B.;Park, E.Y.;Han, Y.G.;Moon, M.W.;Oh, P.Y.;Song, K.B.;Lee, H.J.;Son, C.G.;Jeong, S.H.;Yoo, N.L.;Hong, Y.J.;Jeong, S.J.;Kim, J.H.;Park, S.O.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.929-931
    • /
    • 2006
  • In this experiment, we have investigated that the transported space charge between sub-pixels in AC-plasma cell discharge. The test pulse 30 V, $5{\mu}s$ was applied to the address electrodes of neighbor cells of discharge occurred cells. And we have measured the transported space charge between sub-pixels in accordance with the various last sustain pulse widths t(time gap between the rising edges of sustain and test pulses) of 0.2 to $3{\mu}s$. It was observed that the peak value of transported space charge has been shown to be 21.5pC at $1.0{\mu}s$. And the IR peak value have been occured after $0.51{\mu}s$ with respect to sustain voltage.

  • PDF

High Speed Serial Link Transmitter Using 4-PAM Signaling (4-PAM signaling을 이용한 high speed serial link transmitter)

  • Jeong, Ji-Kyung;Lee, Jeong-Jun;Burm, Jin-Wook;Jeong, Young-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.11
    • /
    • pp.84-91
    • /
    • 2009
  • A high speed serial link transmitter using multi-level signaling is proposed. To achieve high data rate m high speed serial link, 4-pulse amplitude modulation (PAM) is used. By transmitting 2 bit data in each symbol time, high speed data transmission, two times than binary signaling, is achieved. The transmitter transmits current-mode output instead of voltage-mode output Current-mode output is much faster than voltage-mode output, so higher data transmission is available by increasing switching speed of driver. $2^5-1$ pseudo-random bit sequence (PRBS) generator is contained to perform built-in self test (BIST). The 4-PAM transmitter is designed in Dongbu HiTek $0.18{\mu}m$ CMOS technology and achieves 8 Gb/s, 160 mV of eye height with 1.8 V supply voltage. The transmitter consumes only 98 mW for 8 Gb/s transmission.

Prediction for Pore Structure of Cement Mortar Exposed to Freezing-Thawing Action by Ultrasonic Pulse Velocity Measurement (초음파 속도 측정을 통한 동결·융해 작용을 받는 시멘트 모르타르의 공극 구조 예측)

  • Pang, Gi-Sung;Lee, Kwang-Myong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.421-426
    • /
    • 2017
  • In this paper, the effect of freezing-thawing action on the dynamic modulus and porosity was examined by ultrasonic pulse velocity (UPV) measurement. UPV was measured every 30 cycles during the freezing-thawing test, and dynamic modulus and porosity of cement mortar were calculated by relationship among UPV, porosity and dynamic modulus. Porosity analysis was also performed to compare with calculated porosity by mercury intrusion porosimetry (MIP). From the test, it was found that dynamic modulus of cement mortar was decreased 13% after 300 cycles. The calculated porosity was increased about 30% compared with the initial porosity before freezing-thawing action. The calculated porosity showed similar increase tendency with the porosity measured by MIP. So, it can be concluded that the porosity change of cementitious materials by freezing-thawing action can be predicted by UPV measurement.

Prediction models of compressive strength and UPV of recycled material cement mortar

  • Wang, Chien-Chih;Wang, Her-Yung;Chang, Shu-Chuan
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.419-427
    • /
    • 2017
  • With the rising global environmental awareness on energy saving and carbon reduction, as well as the environmental transition and natural disasters resulted from the greenhouse effect, waste resources should be efficiently used to save environmental space and achieve environmental protection principle of "sustainable development and recycling". This study used recycled cement mortar and adopted the volumetric method for experimental design, which replaced cement (0%, 10%, 20%, 30%) with recycled materials (fly ash, slag, glass powder) to test compressive strength and ultrasonic pulse velocity (UPV). The hyperbolic function for nonlinear multivariate regression analysis was used to build prediction models, in order to study the effect of different recycled material addition levels (the function of $R_m$(F, S, G) was used and be a representative of the content of recycled materials, such as fly ash, slag and glass) on the compressive strength and UPV of cement mortar. The calculated results are in accordance with laboratory-measured data, which are the mortar compressive strength and UPV of various mix proportions. From the comparison between the prediction analysis values and test results, the coefficient of determination $R^2$ and MAPE (mean absolute percentage error) value of compressive strength are 0.970-0.988 and 5.57-8.84%, respectively. Furthermore, the $R^2$ and MAPE values for UPV are 0.960-0.987 and 1.52-1.74%, respectively. All of the $R^2$ and MAPE values are closely to 1.0 and less than 10%, respectively. Thus, the prediction models established in this study have excellent predictive ability of compressive strength and UPV for recycled materials applied in cement mortar.

A Study on A Multi-Pulse Linear Predictive Filtering And Likelihood Ratio Test with Adaptive Threshold (멀티 펄스에 의한 선형 예측 필터링과 적응 임계값을 갖는 LRT의 연구)

  • Lee, Ki-Yong;Lee, Joo-Hun;Song, Iick-Ho;Ann, Sou-Guil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.20-29
    • /
    • 1991
  • A fundamental assumption in conventional linear predictive coding (LPC) analysis procedure is that the input to an all-pole vocal tract filter is white process. In the case of periodic inputs, however, a pitch bias error is introduced into the conventional LP coefficient. Multi-pulse (MP) LP analysis can reduce this bias, provided that an estimate of the excitation is available. Since the prediction error of conventional LP analysis can be modeled as the sum of an MP excitation sequence and a random noise sequence, we can view extracting MP sequences from the prediction error as a classical detection and estimation problem. In this paper, we propose an algorithm in which the locations and amplitudes of the MP sequences are first obtained by applying a likelihood ratio test (LRT) to the prediction error, and LP coefficients free of pitch bias are then obtained from the MP sequences. To verify the performance enhancement, we iterate the above procedure with adaptive threshold at each step.

  • PDF

The Effect of Hand Massage on the Anxiety of the Hysterectomy Patients in Immediately prior to Surgery (손마사지가 자궁절제술 환자의 수술직전 불안에 미치는 효과)

  • 김정미
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.2
    • /
    • pp.476-487
    • /
    • 2000
  • The purpose of this study was to examine the effects of hand massage as a nursing intervention on the anxiety of the hysterectomy patients in immediately prior to surgery. The method of this study was Nonequivalent Control Group Non-Synchronized Design. The data were selected from at K university hospital in Pusan, and they consisted of Experimental group-25 patients, Control group -24 patients. The data were collected from Jan. 4 to Jan. 30 in 1999. The subjects′ self-reports of anxiety (measured by the Spielberger Trait-State anxiety Inventory and Visual Analogue Scale developed by Cline et al.) were recorded before and immediately after the intervention. The objective physiologic measures of blood pressure and pulse rate. The collected data were analysed by means of frequency, percentage, standard deviation, chi- square test, t-test, ANCOVA with SPSS program. The results of this study were as following; 1. Hypothesis 1: The 1st hypothesis that "There will be significant difference of the state anxiety level just before surgery in the experimental group and control group" was supported(P= .000). 2. Hypothesis 2: The 2nd hypothesis that "There will be significant difference of the visual analogue scale score just before surgery in the experimental group and control group"was supported(P= .000). 3. Hypothesis 3: The 3rd hypothesis that "There will be significant difference of the systolic and diastolic blood pressure level just before surgery in the experimental group and control group"was supported (P= .003, P= .041). 4. Hypothesis 4: The 4th hypothesis that "There will be significant difference of the pulse rate just before surgery in the experimental group and control group"was supported(P= .004). In conclusion, hand massage is a benefical nursing intervention that alleviates the psychological, physiological anxiety of the hysterectomy patients in immediately prior to surgery. therefore it is recomended to use the hand massage as a nursing intervention for patients undergoing anxiety. The results of this study appear promising, additional research is recomended to further the appropriate uses of hand massage in nursing practice for this and other patient population.

  • PDF

Implementation of crowbar circuit for high-speed discharge·charge switching and its characteristic analysis (고속 방전·충전 스위칭 전원차단회로 설계 제작 및 특성분석)

  • Lee, Min-woong;Cho, Seong-ik;Lee, Nam-ho;Jeong, Sang-hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.885-892
    • /
    • 2017
  • In this paper, we proposed a novel crowbar circuit for high-speed discharge charge switching to solve discharge charge-time delay of supply voltage in the conventional crowbar circuit. The proposed circuit is designed to increase the charge-speed after high-speed discharge of supply voltage, thereby reducing the time exposed to radiation damage and, the normal operation time of electronic system after passing the pulse radiation. The simulation of the discharge charge-times before the implement of the hardware is conducted using Cadence's pspice tool, and DUT (Device Under Test) board is fabricated in the device level. The comparison measurement of the crowbar circuits is performed on the satellite-electronic device for 24V. As the result, we confirmed the high-speed function of the proposed circuit by improvement of the discharge-speed 96.8% and the charge-speed 27.3% as compared with the conventional circuit.

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

Development and Observation Result of High Speed Digital Conversion System of Astronomical Radio Siginal (우주 전파 신호의 고속 디지털 변환 장치 개발과 적용)

  • Kang, Yong-Woo;Song, Min-Gyu;Wi, Seog-Oh;Je, Do-Heung;Lee, Sung-Mo;Kim, Seung-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1009-1018
    • /
    • 2017
  • We developed new Digital Sampler for KVN(: Korean VLBI Network). The sampler has 1024MHz sampling frequency with 2bits/sample. The sampler's input reference frequencies are 1pps(: pulse per second) and 10MHz, also UTC(: Universal Time Coordinated) time information out with 1PPS signal, synchronized. The output of sampling data is adapted VSI(: VLBI Standard Interface) specification including the time information. In order to confirm the performance of the sampler, we carried out the astronomical radio observation test in Ulsan Radio Observatory of KVN. It was confirmed the stable performance. In this paper, We introduce the new developed sampler and present the observational test result.