• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.03 seconds

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

Development of Signal Process Circuit for PSAPD Detector (위치민감형 광다이오드 검출기의 신호처리회로 개발과 적용)

  • Yoon, Do-Kun;Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.315-319
    • /
    • 2012
  • The aim of this study was to develop a signal process circuit for a position sensitive avalanche photodiode detector. The circuit parts consisted of amplification, differential and peak/hold circuit. This research was the baseline to develop highly compact radiation detector. The signal was amplified by an amplification chip and its shape was changed in a differential circuit to minimize the pulse tailing. The peak/hold circuit detect the peak of the signal from the differential circuit and hold the amplitude of the peak for data acquisition. In order to test the intrinsic function of the circuit, the input signal was transmitted from a commercial pulse generator.

연소 안정성 평가 시험을 통한 배플 길이의 안정성 여분 평가

  • Kim, Hong-Jip;Lee, Kwang-Jin;Seo, Seong-Hyeon;Kim, Seung-Han;Han, Yeoung-Min;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.188-196
    • /
    • 2004
  • To optimize and limit the axial length of baffle in KSR-III engine, stability rating tests using pulse gun as one of artificial disturbance devices have been done. Decay time and other parameters for the evaluation of stabilization ability of engine to external perturbation have been analyzed to quantify stabilization capacity of engine, in other words, dynamic stability margin. If baffle does not cover flame zone enough which can be considered as collision region of injector, it wasn't be able to suppress external perturbation sufficiently. The limit of combustion stability margin of engine is assumed to be 50 mm length baffle.

  • PDF

Effects of EMLA Cream Application on Pain Perception and Pain Response of Children with Cancer During Implanted Venous Access Port Needle Insertion (EMLA크림 도포가 소아암환자의 피하매몰 중심정맥포트 바늘삽입 시 통증인지와 통증반응에 미치는 영향)

  • Seo, Hyun-Young;Kim, Young-Hae
    • Child Health Nursing Research
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of EMLA (Eutectic Mixture of Local Anesthetics) cream application on pain perception and pain response during insertion of implanted venous access port needle in children with cancer. Methods: From December 2010 to August 2011, at U university hospital, 20 patients scheduled for implanted venous access port needle insertion were recruited, and randomly assigned to receive either EMLA or a placebo cream 1 hour before the implanted venous access port needle insertion. While conducting needle insertion, changes in pulse and oxygen saturation on the pulse oxymeter monitor were measured and pain behavior reaction was also measured during needle insertion in the treatment room. After conducting needle insertion, self-reported pain reaction, and mothers' perception of the children's pain reaction were measured. Collected data were statistically processed using SPSS version 17.0 for Windows, and analyzed using descriptive statistics, t-test. Results: Children's self-reported degree of pain, degree of pain as perceived by mothers and pain behavior reaction decreased significantly in the EMLA application group compared with the placebo group. Conclusion: Findings indicate that application of EMLA cream is effective in relieving pain in these children during implanted venous access port needle insertion.

Development of a Hardware-in-the-loop Simulator for Spacecraft Attitude Control Using Thrusters

  • Koh, Dong-Wook;Park, Sang-Young;Kim, Do-Hee;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.47-58
    • /
    • 2009
  • In this study, a Hardware-In-the-Loop (HIL) simulator using thrusters is developed to validate the spacecraft attitude system. To control the attitude of the simulator, eight cold gas thrusters are aligned with roll, pitch and yaw axis. Also linear actuators are applied to the HIL simulator for automatic mass balancing to compensate the center of mass offset from the center of rotation. The HIL simulator consists of an embedded computer (Onboard PC) for simulator system control, a wireless adapter for wireless network, a rate gyro sensor to measure 3-axis attitude of the simulator, an inclinometer to measure horizontal attitude, and a battery set to supply power for the simulator independently. For the performance test of the HIL simulator, a bang-bang controller and Pulse-Width Pulse-Frequency (PWPF) modulator are evaluated successfully. The maneuver of 68 deg. in yaw axis is tested for the comparison of the both controllers. The settling time of the bang -bang controller is faster than that of the PWPF modulator by six seconds in the experiment. The required fuel of the PWPF modulator is used as much as 51% of bang-bang controller in the experiment. Overall, the HIL simulator is appropriately developed to validate the control algorithms using thrusters.

Devel opment of Weld Strength Analysis for Dessimilar Metal Friction Welds by Ultrasonic Technique (초음파법에 의한 이종재료 마찰용접강도 해소법의 개발)

  • 오세규;김동조
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.135-149
    • /
    • 1988
  • Friction welding has been shown to have significant economic and technical advantages. However, one of the major concerns in using friction welding is the reliability of the weld quality. No reliable nondestructive test method is available at present for detecting weld quality, particularly in a production environment. Friction welds are formed by the mechanisms of diffusion as well as mechanical interlocking. The severe plastic flow at the interface by forge action of the process brings the subsurfaces so close together that detection of any unbonded area becomes very difficult. This paper presents an attempt to determine the friction weld strength quantitatively using the ultrasonic pulse-echo method. Instead of detecting flaws or cracks at the interface, the new approach calculates the coefficient of reflection based on measured amplitudes of the echoes. It has been finally confirmed that this coefficient could provide the quantitative relationship to the weld quality such as tensile strength, torsional strength, impact value, hardness, etc. So a new nondestructive analysis system of friction weld strength of dissimilar metals using an ultrasonic technique could be well developed.

  • PDF

The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics (AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석)

  • Lee, Young-Jun;Choi, Su-Sam;Park, Se-Kwang;Kim, Yong-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

Properties of concrete incorporating sand and cement with waste marble powder

  • Ashish, Deepankar K.;Verma, Surender K.;Kumar, Ravi;Sharma, Nitisha
    • Advances in concrete construction
    • /
    • v.4 no.2
    • /
    • pp.145-160
    • /
    • 2016
  • Marble is a metamorphic rock used widely in construction which increases amount of marble powder obtained from it. Marble powder is a waste product obtained from marble during its processing. Marble waste is high in calcium oxide content which is cementing property but it creates many environmental hazards too if left in environment or in water. In this research, partial replacement of cement and sand by waste marble powder (WMP) has been investigated. Seven concrete mixtures were prepared for this investigation by partially replacing cement, sand with WMP at proportions of 0%, 10% and 15% by weight separately and in combined form. To determine compressive strength, flexural strength and split tensile strength of concrete made with waste marble powder, the samples at the curing ages of 7, 28 and 90 days was recorded. Different tests of durability were applied on samples like ultrasonic pulse wave test, absorption and sorptivity. For further investigation all the results were compared and noticed that WMP has shown good results and enhancing mechanical properties of concrete mix on partially replacing with sand and cement in set proportions. Moreover, it will solve the problem of environmental health hazard.

Comparison of Ablation Characteristics of Carbon Nanotube reinforced Hybrid Al2O3 by using Ultrashort Pulse Laser (순수 알루미나와 탄소나노튜브 강화 알루미나 복합체의 극초단 펄스레이저 가공특성 비교)

  • Lee, Jun-Young;Yoon, Ji-Wook;Kang, Myung-Chang;Cho, Sung-Hak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.23-29
    • /
    • 2013
  • In this paper, pure $I_{ph}$ and hybrid carbon nanotube reinforced $I_{ph}$ were sintered using the SPS(spark plasma sintering) method for high densification. A nanosecond laser (${\lambda}=1063nm$, ${\tau}P=10ns$) and a femtosecond laser (${\lambda}=1027nm$, ${\tau}P=380fs$) were installed on an optical system for the micromachining test. The ablation characteristics of the pure $I_{ph}$ and CNT/$I_{ph}$ composites, such as thermal effect and ablation depth, were investigated using FE-SEM and a confocal microscope device. Laser machining results for the two mating materials showed improved performances: CNT/$I_{ph}$ composites showed good surface morphology of hole drilling without a melting zone due to the composites' high thermal properties; also, the ablated depth of CNT/$I_{ph}$ was higher than that of pure $I_{ph}$.

A Study on the Output Stabilization of the Nd:YAG Laser by the Monitoring of Capacitor Charging Voltage

  • Noh, Ki-Kyong;Song, Kum-Young;Park, Jin-Young;Hong, Jung-Hwan;Park, Sung-Joon;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.96-100
    • /
    • 2004
  • The Nd: YAG laser is commonly used throughout many fields such as accurate material processing, IC marking, semiconductor annealing, medical operation devices, etc., due to the fact that it has good thermal and mechanical properties and is easy to maintain. In materials processing, it is essential to vary the laser power density for specific materials. The laser power density can be mainly controlled by the current pulse width and pulse repetition rate. It is important to control the laser energy in those fields using a pulsed laser. In this paper we propose the constant-frequency current resonant half-bridge converter and monitoring of capacitor charging voltage. This laser power supply is designed and fabricated to have less switching loss, compact size, isolation with primary and secondary transformers, and detection of capacitor charging voltage. Also, the output stabilization characteristics of this Nd: YAG laser system are investigated. The test results are described as a function of laser output energy and flashlamp arc discharging constant. At the energy storage capacitor charges constant voltage, the laser output power is 2.3% error range in 600[V].