• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.034 seconds

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

The radar development of the low output using the phased array antenna (위상 배열 안테나를 이용한 저출력의 레이더 개발)

  • Cho, Dae-young;Kim, Jeong-hwan;Lee, Myoung-won;Lee, Ju-Hyoung;Lim, Tae-Ho;Yoon, Won-Sang;Ko, Hak-Lim
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.913-920
    • /
    • 2017
  • In this development, By using the phase array antenna, the beam around was electronically revolved and the marine fixed type radar of which the detection is possible was made and the check around was tested. There are the risk of the corrosion because of the abrasion of the axis of rotation and salinity with the way that the existing marine pulse radar detects the check by using the mechanical rotation. Besides, the maintenance cost of the magnetron gets to happen by using the detection signal. In this development, The fixed type radar of the low output which revolves electronically around the beam by using the radar signal processing method of the phase array antenna using the phase shifter and FMCW(Frequency Modulation Continuous Wave) method was made. And by using the fixed type radar, the check detection test was conducted.

Adaptive On-line State-of-available-power Prediction of Lithium-ion Batteries

  • Fleischer, Christian;Waag, Wladislaw;Bai, Ziou;Sauer, Dirk Uwe
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.516-527
    • /
    • 2013
  • This paper presents a new overall system for state-of-available-power (SoAP) prediction for a lithium-ion battery pack. The essential part of this method is based on an adaptive network architecture which utilizes both fuzzy model (FIS) and artificial neural network (ANN) into the framework of adaptive neuro-fuzzy inference system (ANFIS). While battery aging proceeds, the system is capable of delivering accurate power prediction not only for room temperature, but also at lower temperatures at which power prediction is most challenging. Due to design property of ANN, the network parameters are adapted on-line to the current battery states (state-of-charge (SoC), state-of-health (SoH), temperature). SoC is required as an input parameter to SoAP module and high accuracy is crucial for a reliable on-line adaptation. Therefore, a reasonable way to determine the battery state variables is proposed applying a combination of several partly different algorithms. Among other SoC boundary estimation methods, robust extended Kalman filter (REKF) for recalibration of amp hour counters was implemented. ANFIS then achieves the SoAP estimation by means of time forward voltage prognosis (TFVP) before a power pulse occurs. The trade-off between computational cost of batch-learning and accuracy during on-line adaptation was optimized resulting in a real-time system with TFVP absolute error less than 1%. The verification was performed on a software-in-the-loop test bench setup using a 53 Ah lithium-ion cell.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications (초음파센서를 이용한 변량제어 스프레이어)

  • Jeon, Hong-Young;Zhu, Heping
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

Research of the Signal Processing techniques applied to the Command Link Receiver of High Speed Aircrafts (고속 비행체 명령수신기 신호처리 기법 연구)

  • Yun, Jung-Kug;Jung, Won-Hee;Kim, Kyun-Hoe;Yun, Myung-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.266-273
    • /
    • 2016
  • In this paper, we propose the signal processing techniques for the command link receiver mounted to aircrafts flying at a high speed. In order to acquire the various information transmitted from ground through radio frequency links, the wide received signal range must be guaranteed as well as the carrier synchronization and symbol synchronization be performed correctly within short pulse sections. After the synchronization step, we should be able to achieve theoretical performance of the modulation and demodulation scheme applied as deciding bit and symbol at the time appointed. By test results, we make sure that the proposed signal processing techniques can be effectively applied command link receiver mounted to aircrafts.

Validity of Transfusing Group O+ Unmatched Packed Red Blood Cells in Hemorrhagic Shock Patients (출혈성 쇼크 환자에서 비교차시험 O+형 혈액 수혈의 유용성)

  • Lee, Ji-hwan;Choa, Minhong;Cho, Junho;Chung, Sung Pil
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.167-171
    • /
    • 2009
  • Purpose: It is important to begin a transfusion safely and appropriately as soon as possible in a hemorrhagic shock patient. A group $O^+$ unmatched pack red blood cell (universal $O^+$) transfusion may satisfy that requirement. We report our experiences with universal $O^+$ to compare its usefulness for hemorrhagic shock patients with that of a matched pack red blood cell transfusion in the emergency department (ED). Methods: This is a retrospective study. Patients who had systolic blood pressure of less than 90 mmHg or a pulse rate of more than 120 beats per minute in the ED were included, and their medical records were reviewed. The collected data were demographic data, vital signs, blood test results, time to transfusion, the amount of transfusion, complications, and diagnoses. We calculated the emergency transfusion score (ETS) based on the patients' medical records. Results: Two hundred thirty-five patients were included. Forty-eight patients (36 trauma and 12 non-trauma patients) were transfused with a universal $O^+$. These patients had less time to transfusion compared with the cross-matched transfusion groups (35${\pm}$42 versus $170{\pm}187$ minutes, p<0.001). There were no differences in complications between groups (p=0.076). Of the patients who were transfused with universal $O^+$, 94.4% got more than 3 ETS. Conclusion: The universal $O^+$ transfusion, compared with matched pack red blood cell transfusion, should be a useful treatment for ED hemorrhagic shock patient due to its having a shorter time to transfusion without an increase in complications.

The Development of Automatic Grease Lubricator Driven by Gear Mechanism with Controlled Operating Time (주유시간 조절이 가능한 기어 메커니즘 구동방식의 자동그리스주유기 개발)

  • Wang, Duck-Hyun;Lee, Kyu-Young;Lee, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.199-206
    • /
    • 2006
  • Automatic grease lubricator is equipment that provides adequate amount of fresh grease constantly to the shaft and the bearings of machines. It minimizes the friction heat and reduces the friction loss of machines to the least. This research is to develop automatic grease lubricator by gear driven mechanism with controlled operation time. The ultimate design of this equipment is to lubricate an adequate amount of grease by a simple switch clicking according to the advanced set cycle. The backlash of the gear was minimized to increase the output power. To increase the power of gear mechanism, the binding frequency and the thickness of the coil were changed. To control the rotating cycles of the main shaft according to its set numbers, different resistance and chips were used to design the circuit to controls electrical signals with pulse. The body of the lubricator was analyzed by stress analysis with different constructed angle. The stress analysis for differing loading pressures applied to the exterior body of grease lubricator due to the setup angle, was found that the maximum stress was distributed over the outlet part where the grease lubricator suddenly narrowed contracts. Digital mock-up was analyzed and the rapid prototyping(RP) trial products were tested with PCB circuit and grease. The evaluation of the outlet capacity for RP trial products was conducted, because the friction caused by the outlet on the wall surface was an important factor in the operation of the equipment. Finally, the finishing process was applied to decrease the roughness of the surface to a comparable level and was able to test the performance examination for the product.

A Study on the Clinical Diagnosis of Hyperthyroidism (갑상선기능항진증(甲狀腺機能亢進症)의 임상적(臨床的) 진단(診斷)에 관(關)한 연구(硏究))

  • Ku, In-Seo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.7 no.1
    • /
    • pp.15-29
    • /
    • 1973
  • To attain a simple and reliable method of evaluating the thyroid function the reliability of the clinical manifestation and the conventional thyroid function tests in diagnosing the hyperthyroidism was studied. The subjects included 184 patients with hyperthyroidism and 66 cases with euthyroidism, who were treated at the Thyroid Clinic, Seoul National University Hospital, from July 1971 through August 1972. The observed results were as follows: 1. In the cases of hyperthyroidism, 19% of the patients were male and 81% female; in the cases of euthyroidism, 7.6% of the patients were male and 92.4% female. The majority of the patients were in 2nd to 4th decades of their lives. 2. There were objective signs clearly manifested in hyperthyroidism which were rare or absent in the euthyroid state. These clinical signs included wide pulse pressure, tachycardia, systolic murmur, exophthalmos, tremor, and warm skin. In the hyperthyroid state 91.3% of the cases manifested two or more of the above signs, whereas in the euthyroid state no patients manifested any two of the above signs. 3. The most frequent complaints of the patients with thyroid disease were palpitation, weight loss, increased appetite, heat intolerance, perspiration, hunger feeling; nervousness, exertional dyspnea, etc. There was no clear difference in the incidence of the symptoms between hyperthyroidism and euthyroidism. 4. In the diagnosis of hyperthyroidism, the reliability of thyroid ?unction tests was as follows; $T_7$ was 92.4% reliable, $^{125}IT_3$ resin uptake rate 91.6% reliable, $^{131}I$ thyroid uptake rate in 24 hrs. 89.4% reliable, serum $T_4$ level 85.9% reliable and BMR 75.5% reliable. Therefore the careful observation of the clinical manifestation of the disease is a simple and reliable way of making a correct diagnosis of either hyperthyroidism or euthyroidism. 5. In hyperthyroidism there shows no correlationship between the results of the thyroid function test and clinical signs but a high BMR was associated with both tachycardia and systolic murmur.

  • PDF

A Research of Prehospital 119 Emergency Medical Service for Stroke Patients (병원 전 뇌졸중 환자의 구급의료 실태 분석)

  • Song, Hyun-Mok;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.14-20
    • /
    • 2012
  • This study analyzes the influencing factors of prehospital 119 Emergency Medical Service for Stroke Patients in prehospital. From July, 2010 to June, 2011, 123 patients were diagnosed with Stroke in Emergency Medical Center. Among 123 patients, the prehospital assessment rates were as follows : blood pressure checked 73.2 %, pulse checked 73.2 %, respiratory checked 64.2 %, $SpO_2$ checked 79.7 %, pupil reflex test 88.6 %, Electrocardiogram checked 14.6 %, blood sugar checked 19.5 %. Prehospital emergency medical care, Oropharyngeal airway insertion 2.4 %, Manual airway maneuvers 17.1 %, endotracheal intubation 2.7 %, oxygen supply 35.4 %, and suction and intravenous fluid therapy 0 %. The property of mental status evaluation by 119 Emergency Medical Service was nearly perfect, but the patients assessment and emergency medical care were not.