• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.023 seconds

Direct Patterning Technology of Indium Tin Oxide Layer using Nd:$YVO_4$ Laser Beam (Nd:$YVO_4$ 레이저 빔을 이용한 인듐 주석 산화물 직접 묘화 기술)

  • Kim, Kwang-Ho;Kwon, Sang-Jik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.8-12
    • /
    • 2008
  • For the reduction of fabrication cost and process time of AC plasma display panel (PDP), indium tin oxide (ITO) layer was patterned as bus electrode using Nd:$YVO_4$ laser. In comparison with the chemically wet etched ITO patterns, laser ablated ITO patterns showed the formation of shoulders and ripple-like structures at the edge of the ITO lines. For the reduction of shoulders and ripple-like structures, pulse repetition rate and scan velocity of laser was changed. In addition, we analyzed a discharge characteristic of PDP test panel to observe how the shoulders and ripple-like structures influence on the PDP. Based on experimental results, the pattern etched at the 500 mm/s and 40 kHz was better than any other condition. From this experiment we could see the possibility of the laser direct patterning for the application to the patterning of ITO in AC-PDP.

A Study on the Relationship between Dissimilar Metals Friction Welded Joints Strength Properties and Ultrasonic Reflection Coefficients (이종재 마찰용접부 강도특성과 초음파 반사계수와의 상관성에 관한 연구)

  • S. K. Oh;D. J. Kim;S. D. Han
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.34-34
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial application with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristics of the pulse echo effects according to various change in welding conditions. This paper presents a new attempt to detect the bond strength of friction welds by ultrasonic. Instead of looking for a flaw or cracks at the interface, the new approach evaluates the coefficient by reflection which provides a single quantitative indicator involving the acoustic energy reflected at the interface. The objective of this study is to find the relationship between the reflection coefficients and the weld strength. Results of the bar-to-bar friction welding of aluminum to copper and stainless steel and such relationship investigation are presented and interpreted.

A Study on the Relationship between Dissimilar Metals Friction Welded Joints Strength Properties and Ultrasonic Reflection Coefficients (이종재 마찰용접부 강도특성과 초음파 반사계수와의 상관성에 관한 연구)

  • O, Se-Gyu;Kim, Dong-Jo;Han, Sang-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.80-85
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial application with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristics of the pulse echo effects according to various change in welding conditions. This paper presents a new attempt to detect the bond strength of friction welds by ultrasonic. Instead of looking for a flaw or cracks at the interface, the new approach evaluates the coefficient by reflection which provides a single quantitative indicator involving the acoustic energy reflected at the interface. The objective of this study is to find the relationship between the reflection coefficients and the weld strength. Results of the bar-to-bar friction welding of aluminum to copper and stainless steel and such relationship investigation are presented and interpreted.

  • PDF

Content and Educational Needs for Fundamental Nursing Practice (기본간호실습 교육 현황 및 실습교육 필요도)

  • Kim, Kyung-Hee;Chang, Sung-Ok;Kang, Hyun-Sook;Kim, Keum-Soon;Kim, Jong-Im;Kim, Hwa-Soon;Park, Jin-Hee;Eom, Mi-Ran;Youn, Mi-Sun;Lee, Og-Cheol;Won, Jong-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.4
    • /
    • pp.506-519
    • /
    • 2011
  • Purpose: The purpose of this study was to identify content of Fundamental Nursing Practice (FNP) and the educational needs for nursing practice items in schools of nursing. Methods: Participants were 81 professors who were teaching FNP and 166 clinical nurses. The research questionnaire included 148 practice items, which were selected by content analysis of 7 FNP textbooks. Data were collected from May 20 to July 27, 2011 and analyzed using descriptive statistics and t-test with SPSS 17.0. Results: The research findings showed that : 1) the seven items included in the education content of all schools of nursing were putting on sterile gloves, checking radial pulse, checking blood pressure in the arm, Foley catheterization, injection preparation with ampule, intramuscular injection in the buttocks, and mixing intravenous fluid. Fifty items were included in the content in more than 80% of the schools. 2) Educational domains needing emphasis were medication, infection control, health assessment, oxygenation, urinary elimination, activity/positioning, and nutrition. There were significant differences in reported educational needs between professors and clinical nurses for 62.8% of practice items. Conclusions: Results indicated that standardization of FNP education contents using the findings of this study should lead to improvement in quality of FNP education.

The Effects on Cutting Performance by Machining Parameters of Nd : YAG Laser (Nd : YAG레이저의 가공 파라메터가 절단 성능에 미치는 영향에 관한 연구)

  • 한응교;박두원;이범성;이명호;임흥순
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.1-12
    • /
    • 1992
  • Generally, laser machines with high generated power can be developed by means of enhancing their mean power, since the enhancement of mean power exerts an influence on peripheral parameters and machining performance. In this research, we evaluate the various machining properties by the use of two machines which bear different mean power each other, so that we may study various effects of the enhancement of mean power. As a result, when the mean power comes to be enhanced to 75%, we obtain the increase of output energy up to 69% and of peak power more than 95%, and also obtain almost twice of the cutting speed. Moreover we find the fact that if the test pieces have enough thickness in contrast with output energy, the pulse frequency moves toward the frequency bandwidth which takes proportion to the cutting speed mas well as to the amount of material removal per unit time. In addition it is finally obtained that the laser machine with high output power yields small taper degrees at kerf parts, while it has large cutting widiths and dross lengths.

Comparison of Effects of Transcutaneous Electrical Nerve Stimulation (TENS) and San-Yin-Jiao (SP6) Acupressure on Primary Dysmenorrhea (경피신경전기자극(TENS)과 삼음교 지압이 원발성 월경통에 미치는 효과 비교)

  • Oh, Yeong-Taek
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • PURPOSE: This study examined the effect of high-frequency transcutaneous electrical nerve stimulation (TENS) and San-Yin-Jiao (SP6) acupressure on primary dysmenorrhea. Furthermore, the difference in effectiveness between the two methods were compared. METHODS: Twenty-six students participated in this study, and were randomly assigned to a high-frequency TENS group(experimental 1, n=9), a San-Yin-Jiao (SP6) acupressure group(experimental 2, n=9), and no treatment group(control, n=8). They were assessed and treated on the first day of their menstruation. The TENS protocol included applying 20 minutes of stimulation with a frequency of 100Hz, $100{\mu}sec$ pulse width. Four electrodes were placed on the skin 3 cm from midline at T12-L1 and S2-3 paravertebral muscles. San-Yin-Jiao (SP6) acupressure should be applied with the thumb for 10 minutes(8 seconds pressure and 2 seconds rest) on the SP6 acupoint. This procedure should be repeated for the other foot. Dysmenorrheal pain measured two pain assessment tools (VAS, DPT) pre-treatment; immediate post-treatment; 30minutes, 1, 2hours; and 3, 4, 5, 6, 24 hours after the VAS test were added. RESULTS: The results showed significant differences in pain assessments (VAS, DPT) after treatment for subjects of experimental group1 (p<.05) and experimental group2 (p<.05), whereas the between-group comparison found no statistically significant differences. CONCLUSION: This result supports the idea that using two methods could be effective in pain reduction among students who suffered from primary dysmenorrhea.

Vibration and Acoustic Noise characteristic on SRM with compensating winding by two stage commutation (2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성)

  • 오석규;이종근;최태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.250-257
    • /
    • 2001
  • SRM drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM drive. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a two stage commutation method during commutation period. This paper suggests an SRM excitation scheme using unidirect-short compensation winding to reduce vibration of the motor. The motor is excited by a tow stage commutation method during commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

An E-mail survey for expanding the basic benefit package of Korean medicine in Korean national health insurance (한의 의료행위 급여 항목 확대 방안 모색을 위한 전자우편 설문조사)

  • Kim, Mikyung;Kim, Ga-hee;Han, Chang-ho
    • The Journal of Korean Medicine
    • /
    • v.39 no.3
    • /
    • pp.51-60
    • /
    • 2018
  • Objectives: This study aimed to investigate the opinions of Korean medical doctors on how to elucidate possible remedial measures for expanding the health insurance benefits coverage item of Korean medicine (KM). Methods: An online survey was conducted to all members who had registered e-mail address in the association of Korean medicine from 1 to 17 November, 2016. Statistical analysis was performed and odds ratio with 95% confidence interval were calculated by each subgroup. Results: A total of 743 members answered the questions and the response rate was 4.1%. The priorities for expanding health insurance benefits were as follows: thermographic imaging, Sasang constitution typing test, and pulse wave among examinations; pharamacopuncture, embedding acupuncture, and acupotomy among procedures; Chuna manual therapy, manual therapy for meridian muscle, and Daoyin exercise therapy among manual therapies; low-frequency electrical therapy, traction, paraffin bath, and light therapy among physical therapies; and aromatherapy, enema therapy, and color therapy among activities of KM. Conclusions: It should be covered by the national health insurance (NHI) of KM that thermographic imaging, pharmacoacupuncture, Chuna manual therapy, low-frequency electrical therapy, aromatherapy as a top priority. We also suggest that basic medical tests, such as blood, urine, or imaging, should be included in the coverage of the NHI of KM. It is necessary to review the expertise and public opinions about the plans and priorities for the conversion of the desired medical services to be covered by the NHI.

Improvement of PENS on Peripheral Nerve Conduction Function in STZ-Induced Diabetic Rats (당뇨유발백서에서 피하신경전기자극의 말초신경기능 개선효과)

  • Kim, Yang-Ho;Chang, Mee-Kyung;Shin, Min-Chul
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.4
    • /
    • pp.19-26
    • /
    • 2006
  • Purpose: This study aimed the effects of percutaneous electric nerve stimulation (PENS) applied to different parts of the streptozotocin-induced diabetic rats on the change of glucose and nerve. Methods: rats (ten weeks old) were selected as the subjects; the normal group was five rats, and the diabetes induction group II, III and IV were five rats, respectively, which were randomly sampled from the twenty-five streptozotocin-administered rats with more than $240\;d{\ell}/m{\ell}$ of blood sugar. For PENS, electric current with 2 Hz of stimulation frequency and $200\;{\mu}s$ of pulse duration was applied to the subjects for fifteen minutes a day, six days a week, for three weeks. Calculation of glucose and weight, and nerve conduction test were conducted forty-eight hours and three weeks after streptozotocin administration, respectively. Results: As for change of glucose and weight, the group III with stimulation to the acupoints and the group IV with stimulation to non-acupoints showed significant differences from the control group II (p<0.05). As for MNCV (motor nerve conduction velocity), the group III with stimulation to the acupoints showed significant differences from the group IV with stimulation to non-acupoints and the control group II (p<0.05). Conclusion: PENS had the effects of inhibiting increase of glucose, change of weight and decrease of nerve conductive function between the distal and proximal ends of the peripheral nerve in the STZ-induced diabetic rats.

  • PDF

Design and Operational Charcteristics of 150MW Pulse Modulator (150MW 펄스 MODULATOR의 설계 및 동작특성)

  • Park, S.S.;Oh, J.S.;Lee, K.T.;Kim, S.H.;Son, Y.K.;Choi, K.;Chang, S.D.;Park, S.W.;Nam, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.928-930
    • /
    • 1992
  • The design beam energy of PLS(Pohang Accelerator Laboratory) Linac is 2Gev. The linac employs total 11 units of modulators and klystrons. The maximum peak output powers of the modulators are 200MW (400kV, 500A, 4.4$\mu$S flat-top, 800$\Omega$ load) to drive the klystrons which have the peak microwave power of 80MW. Prior to the development of the 200MW modulators, a prototype 150MW modulator has been constructed and tested. We have achieved output pulses of 350kV, 420A and 3.5$\mu$S flat-top with 840$\Omega$ water load. In this article, the test results and computer simulations of charging, De-Q'ing, and discharging are presented.

  • PDF