• Title/Summary/Keyword: Pulse survey

Search Result 94, Processing Time 0.033 seconds

Development of a Guideline for the Application of Diagnostic Devices for Menopausal Syndrome: Literature Review and Questionnaire Survey (갱년기장애 진단기기 사용에 대한 지침 개발 : 문헌검토 및 설문조사)

  • Baek, Seon-Eun;Park, Eun-Ji;Kim, Dong-Il;Lee, In-Seon;Yoo, Jeong-Eun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.3
    • /
    • pp.65-78
    • /
    • 2017
  • Objectives: This study was aimed to develop a guideline for the application of diagnostic devices for menopausal syndrome. Methods: We conducted a literature review and a questionnaire survey on diagnostic devices including Digital Infrared Thermal Imaging (DITI), pulse diagnosis device, Heart Rate Variability (HRV), body composition analyzer, Yangdorak. Results: We retrieved some clinical values for usage of devices from the articles. Especially, DITI was useful to identify the pattern of body temperature distribution. The respondents answered that they diagnosed menopausal syndrome by using body composition analyzer (62.3%), DITI (60%), HRV (60%), pulse diagnosis device (45.7%), Yangdorak (34.3%). The respondents answered that they don't use diagnostic devices when they diagnosed menopausal syndrome because of absence of device, cost, difficulty of interpretation, substitution of another diagnostic method. After experts survey, it was recommended to use DITI, HRV, body composition analyzer. There was no consensus on the use of pulse diagnosis device, Yangdorak in diagnosing menopausal syndrome. Conclusions: We developed a guideline for the application of diagnostic devices for menopausal syndrome.

Analysis and Classification of Broadband Acoustic Echoes from Individual Live Fish using the Pulse Compression Technique (펄스압축기법을 이용한 활어 개체어에 대한 광대역 음향산란신호의 분석 및 식별)

  • Lee, Dae-Jae;Kang, Hee-Young;Kwak, Min Son
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.2
    • /
    • pp.207-220
    • /
    • 2015
  • This study identified the species-specific, frequency-dependent characteristics of broadband acoustic scattering that facilitate classifying fish species using the pulse compression (PC) technique. Controlled acoustic scattering laboratory experiments were conducted with nine commercially important fish species using linear chirp signals (95-220 kHz) over an orientation angle range of ${\pm}45^{\circ}$ in the dorsal plane at approximately $1^{\circ}$ increments. The results suggest that the angular-dependent characteristics of the broadband echoes and the frequency-dependent variability in target strength (TS) were useful for inferring the fish species of interest. The scattering patterns in the compressed pulse output were extremely complex due to morphological differences among fish species, but the x-ray images strongly suggested that spatial separation correlated well with scattering for the head, skeleton, bone, otoliths, and swim bladder within each specimen.

A Study on New Geoelectric Survey and Instrumentation Using Low Frequency Electric Field Sensing Antenna (저주파 Electric Field Sensing Antenna를 이용한 새로운 탐사 및 계측에 관한 연구)

  • 배명수;여영호;손수국
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper has been studied a new geoelectric survey and instrunmentation using Low Frequency Electric Field .sensing Antenna. “Low Frequency Electric Field Sensing” is a technology in new method of survey to use array type antenna, the power of operation in antenna is using AC or DC pulse instead of DC current. The architecture of system embodied transceiver system using a microprocessor(PIC) of Microcllip Technology Inc. An array antenna design and il control transmission of antenna to use CDMA in this system. It is using array type antenna for the earth、earth's crust to survey explain from theory and experience.

  • PDF

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

The Association of Urine Microalbumin and Pulse Pressure in Korean Adults (한국 성인에서 뇨 중 Microalbumin과 맥압의 관련성)

  • Gee, Mee Young;Yoon, Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.3
    • /
    • pp.183-187
    • /
    • 2016
  • The aim of this study was to assess the association between microalbumin and pulse pressure (PP) in Korean adults. The study subjects were Korean adults 20 years or older (n=4,948) who participated in the Korea National Health and Nutrition Examination Survey 2012. The urine microalbumin level ($M{\pm}SE$) was significantly higher (p=0.047) in the high PP group (PP>60.0 mmHg) [$33.02{\pm}4.93{\mu}g/mL$ (95% confidence interval (CI), 23.37~42.68)] than the normal PP group ($PP{\leq}60.0mmHg$) [$22.57{\pm}1.63{\mu}g/mL$ (95% CI, 19.36~25.77)], after adjusting for age, gender, smoking, drinking, regular exercising, WM, BMI, TC, TG, HDL-C, FBG, BUN, creatinine, and urine creatinine. In conclusion, pulse pressure was associated with the microalbumin level in Korean adults.

The Study of Relationship of Obesity and Abdominal Obesity and Pulse Pressure Using Big Data (빅 데이터를 활용한 비만 및 복부비만이 맥압에 미치는 영향에 대한 연구)

  • Yoon, Yeung-Yoon;Kim, Sung-Gil;Shin, Ji-Hoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.187-192
    • /
    • 2018
  • The aim of this study was to assess the association of obesity and abdominal obesity and pulse pressure (PP) in Korean adults. The study subjects were Korean adults 20 years or older (n=5,889) who participated in the Korea National Health and Nutrition Examination Survey 2012. After adjusting for relevant variables (include age), in women, the odds ratio (OR) of High PP (PP >61 mmHg) of the obesity [1.37 (95 % CI, 1.03-1.82)] and abdominal obesity [1.38 (95% CI, 1.07-1.78)] group compared to the normal group was not significant. However, in men, the OR of High PP of the obesity and abdominal obesity group compared to the normal group was not significant. In conclusion, the obesity and abdominal obesity were associated with pulse pressure in Korean women, but not in men.

Effects of Forest Bathing at Samdasu Forest in Jeju on Pulse and Stress (제주 삼다수 숲 산림욕이 맥박과 스트레스에 미친 효과)

  • Sin, Bang Sik;Lee, Jae H.;Song, Kyu J.;Shin, Aran;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2021
  • Purposes: We studied whether forest bathing is effective in improving the stress of the human body. Therefore, we investigated changes in pulse rate, stress index, and autonomic nervous system after 2 hours of forest bathing on Jeju Samdasu Forest Methods : The study was conducted before and after forest bathing through heart rate variability and questionnaire. Results: After forest bathing, the average pulse rate of the experimental group was significantly increased. The stress index significantly decreased in the post-test in the experimental group. The cumulative stress, sympathetic activity (LF), parasympathetic activity (HF) change, and LF/HF ratio were slightly different from those of post-test in the experimental group, but were not statistically significant. In the survey of job stress average index and state characteristic anxiety index through questionnaire, it decreased significantly after forest bathing (p<.001). Conclusions: The Samdasu forest bathing has been proven effective in enhancing pulse and reducing stress, so it is evaluated that forest bathing is effective in promoting health.

Effects of Aroma inhalation on Blood Pressure, Pulse Rate, Sleep, Stress, and Anxiety in Patients with Essential Hypertension (아로마 흡입이 본태성고혈압 환자의 혈압, 맥박, 수면, 스트레스, 불안에 미치는 효과)

  • Choi, Eun-Mi;Lee, Kyung-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • Purpose: This experimental research explored the effects of aroma inhalation on blood pressure, pulse, sleep, stress, and anxiety in patients with essential hypertension who are taking antihypertensive medication. Methods: A pilot survey, pre-test and post-test were conducted. The data were collected from August to October, 2009. The participants were 44 patients randomly assigned to an experimental group (22 people) and a control group (22 people). The experimental group received individual instruction for aroma inhalation, which lasted for 3 minutes. They inhaled blended oils of Lavender, Majoram and Ylang Ylang (The mixed ratio was 4:3:3), three times a day, for two weeks. Data from 36 patients were used for the final analysis (20 from the experimental group, 16 from the control group). Data were analyzed using SPSS version 13.0. Results: Sleep disturbance decreased in the experimental group (t=-2.258, $p$=.030). Blood pressure, pulse, stress, and anxiety were not significantly different between the two groups ($p$ >.05). Additional analysis of the experimental group showed that physical stress and psychological stress were significantly lowered. Conclusion: Aroma inhalation is an effective paramedical intervention for patients with essential hypertension.

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

Beta Gamma Survey Meter (베타 및 감마선 계측용 서어베이 미터)

  • 박인용;이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1971
  • A survey meter which is used a G-M counter sensitive to beta and gamma radiation is studied. This device is completely transistorized, operated with battery, and can be read directly the 3 full-scale meter range: 2.5, 25 and 250 MR/HR respectively. The collector-coupled monostabel multivibrator consisting of a counting-rate meter circuit, and the astable blocking oscillator consisting of a dc-de converter for power supply are analyzed and derived the design dquations. To improve the resolving time of the G-M counter the device is designed to be triggered by low pulse in the order of 0.5v.

  • PDF