• Title/Summary/Keyword: Pulse sequence

Search Result 307, Processing Time 0.031 seconds

Basic and Advanced MR Pulse Sequence - Fundamental Understanding-

  • 장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.15-29
    • /
    • 2002
  • MRI에서 펄스 시퀀스(pulse sequence)란 고주파 RF(radiofrequency) 펄스 및 경사자장(gradient) 펄스를 가하고 MR 신호를 획득하는 순서를 시간대별로 도식화 한 pulse diagram을 이야기한다. 이러한 pulse sequence는 실제로 영상을 획득하기 위한 RF amplifier, gradient amplifier 등의 하드웨어를 순차적(sequential)으로 구동하는 역할을 한다. 따라서 이러한 pulse sequence는 현재 임상적으로 사용되는 다양한 영상기법들을 이해하는데 필수적이다.

  • PDF

A STUDY ON MAGNETIC RESONANCE IMAGING OF THE TEMPOROMANDIBULAR JOINT (악관절에 대한 자기 공명 영상의 연구)

  • Kim Hyung Sik;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.187-198
    • /
    • 1990
  • Examinations of the temporomandibular joints were performed on a 1.5 Tesla magnetic resonance (MR) system. An MR surface receiver coil 3 inch in diameter was placed on plastic frame, the patient's head being placed in the frame so that the coil was pressed against the temporal region. In taking advantage of the magnetic resonance imaging that has been studied briskly till now, author obtained the images of parasagittal and paracoronal planes about the temporomandibular joint by using MPGR (Multi-Planar Gradient Recalled), GRASS (Gradient Recalled Acquisition in the Steady State), and CSMEMP (Contiguous Slice Multiple Echo, Multi-Planar), that differ from the Spin Echo pulse sequence which the previous authors used. Five subjects with no symptoms of temporomandibular joint pain and dysfunction were studied. The plane images obtained by these methods were compared with those by Spin Echo pulse sequence. The results were as follows: 1. The optimal repetition times (TR) and echo times (TE) for T.M.J. image were; a. 400 msec and 18 msec in PMGR pulse sequence. b. 40 msec and 12 msec in GRASS pulse sequence. c. 700 msec and 30 msec in CSMEMP pulse sequence. d. 500 msec and 20 msec in Spin Echo pulse sequence. 2. When the MPGR pulse sequence was using, T2-weighted image was obtained in very short time. On the image of the paracoronal plane by GRASS pulse sequence, meniscus showed the moderate signal intensity, and the meniscus and its anteromedial, posterolateral attachments were observed definitely with gray color. 4. The signal intensity of Spin Echo pulse sequence was equal to that of CSMEMP pulse sequence, but the image by CSMEMP pulse sequence showed relatively lower level in its resolution.

  • PDF

T2 Relaxographic Mapping using 8-echo CPMG MRI Pulse Sequence

  • E-K. Jeong;Lee, S-H.;J-S. Suh;Y-Y wak;S-A. Shin;Y-K. Kwon;Y. Huh
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.7-20
    • /
    • 1997
  • The mapping of the spin-spin relaxation time T2 in pixed-by-pixel was suggested as a quantitative diagnostic tool in medicine. Although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any misregistration of each pixel's signal for the fitting T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17∼20 msec can give the reliable T2 map.

  • PDF

Power Spectrum of Jittered Random Pulse Train (불규칙 Pulse 신호의 전력 Spectrum)

  • 최양희;김재경
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.1
    • /
    • pp.10-13
    • /
    • 1980
  • The power spectrum of jittered pulse train is derived for the independent stationary pulse sequence with a stationary Gaussian phase jitter. For the unipolar pulse train signal, it is shown that as the phase jitter increases, the continuous Part of the power spectrum increases chile the discrete part decreases.

  • PDF

FPGA implementation of A/D converter using stochastic logic (FPGA를 이용한 확률논리회로 A/D 컨버터의 구현)

  • 이정원;심덕선
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.847-850
    • /
    • 1998
  • One of the most difficult problem of designing VLSI is a mixed-circuit design, that is to design circuit containing both analog parts and digital parts. Digital to analog converter and analog to digital converter is a typical case. Especially it can be a serious problem when mixed circuit are put into a large digital circuit like microcontroller. However nowadays this problem is settled by separating analog circuit parts outside the IC. This technique is based on converting a digital signal into a pulse sequence. Then an analog signal is obtained by averaging this pulse sequence at the external low-pass filter. An anlog to digital converter is designed using a stochastic logic instead of a traditional PWM (pulse-width modulation) signal and ins implemente dusing FPGa. Stochastic pulse sequence can be made as a simple circuits and moreover can be mathematically processed by simple circuits -AND gates. The spectral property of stochastic pulse sequence method is better than that of PWM method. So it make easy to design a external low-pass filter. This technique has important advantages, especially the reduction of the ADC cost.

  • PDF

Computer-Aided Crafting of Pulse Shapes for Broadband Heteronuclear Decoupling in the presence of Homonuclear Coupling

  • Lee, Chang-Jae
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.3 no.1
    • /
    • pp.36-43
    • /
    • 1999
  • We present a pulse shape tailored for broadband decoupling for a system of spin-1/2's with scalar couplings as well. In crafting the pulse shape Coherent Averaging Theory and Fourier expansion method are used. The Fourier expansion coefficients are optimized numerically by applying the Simulated Annealing Method. The decoupling performance of the shaped pulse thus designed is then compared with the well-known composite pulse sequence, DIPSI-2. It is shown that the shaped pulse performs well even at the conditions where the DIPSI sequence begins to fail.

  • PDF

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.26 no.4
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF

A Novel M-ary Code-Selected Direct Sequence BPAM UWB Communication System

  • Bai, Zhiquan;Kwak, Kyung-Sup
    • ETRI Journal
    • /
    • v.28 no.1
    • /
    • pp.95-98
    • /
    • 2006
  • In this letter, a novel M-ary code-selected direct sequence (DS) ultra-wideband (UWB) communication system is presented. Our purpose is to achieve a high data rate by an M-ary code-selected direct sequence bipolar pulse amplitude modulation (MCSDS-BPAM) scheme. In this system, a particular DS code sequence is selected by the $log_2M$/2 bits from the DS gold code set. This scheme can accomplish both a high data rate without increasing the system bandwidth or changing the pulse shape and improve the BER with an increase of modulation level M even at a lower signal-to-noise ratio (SNR). The receiver signal processing algorithm is given for an MCSDS-BPAM UWB system over an ideal AWGN channel and correlation receivers.

  • PDF

A Detection Algorithm for Pulse Repetition Interval Sequence of Radar Signals based on Finite State Machine (유한 상태 머신 기반 레이더 신호의 펄스 반복 주기 검출 알고리즘)

  • Park, Sang-Hwan;Ju, Young-Kwan;Kim, Kwan-Tae;Jeon, Joongnam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.85-91
    • /
    • 2016
  • Typically, radar systems change the pulse repetition interval of their modulated signal in order to avoid detection. On the other hand the radar-signal detection system tries to detect the modulation pattern. The histogram or auto-correlation methods are usually used to detect the PRI pattern of the radar signal. However these methods tend to lost the sequence information of the PRI pulses. This paper proposes a PRI-sequence detection algorithm based on the finite-state machine that could detect not only the PRI pattern but also their sequence.