• Title/Summary/Keyword: Pulse rates

Search Result 244, Processing Time 0.037 seconds

Comparative Study on the Growth Dynamics of Some Grasses (몇 종의 벼과식물에 관한 생장동태의 비교 연구)

  • Choung, Yeon-Sook
    • The Korean Journal of Ecology
    • /
    • v.16 no.3
    • /
    • pp.329-339
    • /
    • 1993
  • Effects of relative light intensity and N, P fertilization on the growth and ramet dynamics of the rhizomatous plants, Arundinella hirta, Miscanthus sinensi and Spdiopogon sibiricus were studied in Chuncheon, Kangweon-Do. Ramets emerged in one pulse a year, withered in one pulse at the end of the growing season in M. sinensis and S. sibircus stands, while the birth and death pulse in A. hirta stands were two times. Total births of ramet were 9 times and 3.6 times greater in the unshaded fertilized stands of A. hirta and M. sinensis than in the shaded, However, those of S.sibiricus were 2.1 times greater in the shaded stands. Flowering rates of A. hirta, M.sinensis and S.sibiricus I the unshaded fertilized stands were 1.8, 2.7 and 1.04 times greater than in the shaded unfertilized stands, respectively. Height of ramets of A. hirta and M.sinensis were the hightest in the unshaded fertilized stands. However, that of s.sibiricus was the highest in the shaded fertilized stand. Aboveground production of A.hirta in the fertilized stand was 2.4 times greater in the unshaded stand than in the shaded one. Results of inflorescence frequency, shoot height and the ratio of aboveground to belowground were smiliar to the total births. The added fertilizer markedly increased the ramet density and the shoot productivity of three rhizomatous plants, especially of A. hirta.

  • PDF

Fatigue Characteristics of PZT Thin Films Deposited by ECR-PECVD

  • Chung, Su-Ock;Lee, Won-Jong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.4
    • /
    • pp.177-185
    • /
    • 2005
  • Fatigue characteristics of lead zirconate titanate (PZT) films deposited by electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) were investigated. The fatigue characteristics were investigated with respect to PZT film thickness, domain structure, fatigue pulse height, temperature, electrode materials and electrode configurations. The used top and bottom electrode materials were Pt and $RuO_2$. In the fatigue characteristics with fatigue pulse height and PZT film thickness, the fatigue rates are independent of the applied fatigue pulse height at the electric field regions to saturate the P-E hysteresis and polarization $(P^*,\;P^A)$ characteristics. The unipolar and bipolar fatigue characteristics of PZT capacitors with four different electrode configurations $(Pt//Pt,\;Pt//RuO_2,\;RuO_2//Pt,\;and\;RuO_2//RuO_2)$ were also investigated. The polarization-shifts during the unipolar fatigue and the temperature dependence of fatigue rate suggest that the migration of charged defects should not be expected in our CVD-PZT films. It seems that the polarization degradations are attributed to the formation of charged defects only at the Pt/PZT interface during the domain switching. The charged defects pin the domain wall at the vicinity of Pt/PZT interface. When the top and bottom electrode configurations are of asymmetric $(Pt//RuO_2,\;RuO_2//Pt)$, the internal fields can be generated by the difference of charged defect densities between top and bottom interfaces.

Development of a High Voltage Semiconductor Switch for the Command Charging o (모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발)

  • Park, S.S.;Lee, K.T.;Kim, S.H.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF

Three-Temperature Modeling of Carrier-Phonon Interactions in Thin GaAs Film Structures Irradiated by Picosecond Pulse Lasers

  • Lee Seong-Hyuk;Lee Jung-Hee;Kang Kwan-Gu;Lee Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1292-1301
    • /
    • 2006
  • This article investigates numerically the carrier-phonon interactions in thin gallium arsenide (GaAs) film structures irradiated by subpicosecond laser pulses to figure out the role of several recombination processes on the energy transport during laser pulses and to examine the effects of laser fluences and pulses on non-equilibrium energy transfer characteristics in thin film structures. The self-consistent hydrodynamic equations derived from the Boltzmann transport equations are established for carriers and two different types of phonons, i.e., acoustic phonons and longitudinal optical (LO) phonons. From the results, it is found that the two-peak structure of carrier temperatures depends mainly on the pulse durations, laser fluences, and nonradiative recombination processes, two different phonons are in nonequilibrium state within such lagging times, and this lagging effect can be neglected for longer pulses. Finally, at the initial stage of laser irradiation, SRH recombination rates increases sufficiently because the abrupt increase in carrier number density no longer permits Auger recombination to be activated. For thin GaAs film structures, it is thus seen that Auger recombination is negligible even at high temperature during laser irradiation.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects (당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Park, Su-Jeong;Kim, Kyung-Yo;Lee, Si-Woo;Kwon, Young-Mi;Kil, Eun-Young;Joo, Jong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.

Development of 20kV Pulse Power Charging System (20kV급 Capacitor Charging Power System 개발)

  • Jeong, I.W.;Rim, G.H.;Choi, Y.W.;Lee, H.S.;Kim, J.S.;Ryoo, H.J.;Gusev, G.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.213-214
    • /
    • 2001
  • This paper describes a power supply for a rapid pulse power charging system designed for charging a $0.35{\mu}F$ capacitor to 20kV in approximately 3ms. The power supply should be capable of recharging the load capacitor maximum 300 times within one second. This power supply is based on a series resonant 3-phase inverter followed by the step-up transformers. The experiments have been carried out at different repetition rates and charging voltages.

  • PDF

Spiking Suppression of Quasi-continuous-wave Pulse Nd:YAG Laser Based on Bias Pumping

  • Chen, Yazheng;Wang, Fuyong
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.400-406
    • /
    • 2022
  • We numerically demonstrate that the inherent spiking behavior in the quasi-continuous-wave (QCW) operation of an Nd:YAG laser can be suppressed by adopting bias pumping. After spiking suppression, the output QCW pulses from a bias-pumped Nd:YAG laser are very stable, and they can maintain nearly the same temporal shape as that of pump pulse under different pump repetition rates and peak powers. Our study implies that bias pumping is an alternative method of spiking suppression in solid-state lasers, and the application areas of an Nd:YAG laser may be extended by bias pumping.

Classification Model of Chronic Gastritis According to The Feature Extraction Method of Radial Artery Pulse Signal (맥파의 특징점 추출 방법에 따른 만성위염 판별 모형)

  • Choi, Sang-Ho;Shin, Ki-Young;Kim, Jeauk;Jin, Seung-Oh;Lee, Tea-Bum
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.185-194
    • /
    • 2014
  • One in every 10 persons suffer from chronic gastritis in Korea. Endoscopy is most commonly used to diagnose the chronic gastritis. Endoscopic diagnosis is precise but it is accompanied with pain and high cost. According to pulse diagnosis in Traditional East Asian Medicine, health problems in stomach can be diagnosed with radial pulse signals in 'Guan' location in the right wrist, which are non-invasive and cost-effective. In this study, we developed a classification model of chronic gastritis using pulse signals in right 'Guan' location. We used both linear discrimination method and logistic regression model with respect to pulse features obtained with a peak-valley detection algorithm and a Gaussian model. As a result, we obtained sensitivity ranged between 77%~89% and specificity ranged between 72%~83% depending on classification models and feature extraction methods, and the average classification rates were approximately 80%, irrespective of the models. Specifically, the Gaussian model were featured by superior sensitivities (89.1% and 87.5%) while the peak-valley detection method showed superior specificities (82.8% and 81.3%), and the average classification rate (sensitivity + specificity) of the Gaussian model was 80.9% which was 1.2% ahead of the peak-valley method. In conclusion, we obtained a reliable classification model for the chronic gastritis based on the radial pulse feature extraction algorithms, where the Gaussian model was featured by outperformed sensitivity and the peak-valley method was featured by outperformed specificity.

Effects of Venesection at the Sybsun-points on Blood Pressure and Body Temperature and Pulse Rate in Humans (남녀 대학생에서 십선혈(十宣穴) 사혈(瀉血)이 혈압, 체온 및 맥박수에 미치는 영향)

  • Lee, Dong-Gun;Jeong, Won-Je;Lee, Hyun-Jin;Cho, Hyun-Seok;Kim, Kyung-Ho;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives : Sypsun-points are located at the tips of all fingers, 0.1 chon(寸) from the finger nails, totaling 10 points on both hands. These points have been used for emergency care, fainting, epilepsy, cerebrovascular accidents, hypertension, unconsciousness, high fever etc. in oriental medicine. The most common technique is bleeding with a needle at these points. We investigated whether Venesection at the Sybsun-points has effects on blood pressure and body temperature and pulse rate in humans aged from 20 to 30 who had no specific past history and whose vital signs are in normal range. Methods : 67 persons were studied from March to June 2008. They were composed of Sample group(n=36) and Normal group(n=31). Both two groups kept a steady state an hour before venesection. In both group, we checked blood pressure and body temperature and pulse rates 6 times( 30min. before and just before treatment, and just after, 30, 60, 90min after treatment). All study environments were same between sample and normal group. But only, normal group didn't carry out venesection at the Sybsun-points. Results : In a comparison of before and after venesection at the Sybsun-points, any Statistical significance was not evaluated. Though pulse rate in sample group was significantly decreased after venesection(p<0.05), it has no statistical significance because normal group's pulse rate was also significantly decreased and between two groups had no statistical difference. Conclusions : Though further study is needed, our findings suggest that venesection at the Sybsun-points has no significant effect on blood pressure and body temperature, and pulse rate in humans who had no specific past history and whose vital signs are in normal range. Also in that case, we may know that pain and tension result from venesection at the Sybsun-points have no significant effect on blood pressure and body temperature and pulse rate.

  • PDF

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF