• Title/Summary/Keyword: Pulse rate

Search Result 1,676, Processing Time 0.035 seconds

Systematic test on the effectiveness of MEMS nano-sensing technology in monitoring heart rate of Wushu exercise

  • Shuo Guan
    • Advances in nano research
    • /
    • v.15 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • Exercise is beneficial to the body in some ways. It is vital for people who have heart problems to perform exercise according to their condition. This paper describes how an Android platform can provide early warnings of fatigue during wushu exercise using Photoplethysmography (PPG) signals. Using the data from a micro-electro-mechanical system (MEMS) gyroscope to detect heart rate, this study contributes an algorithm to determine a user's fatigue during wushu exercise. It sends vibration messages to the user's smartphone device when the heart rate exceeds the limit or is too fast during exercise. The heart rate monitoring system in the app records heart rate data in real-time while exercising. A simple pulse sensor and Android app can be used to monitor heart rate. This plug-in sensor measures heart rate based on photoplethysmography (PPG) signals during exercise. Pulse sensors can be easily inserted into the fingertip of the user. An embedded microcontroller detects the heart rate by connecting a pulse sensor transmitted via Bluetooth to the smartphone. In order to measure the impact of physical activity on heart rate, Wushu System tests are conducted using various factors, such as age, exercise speed, and duration. During testing, the Android app was found to detect heart rate with an accuracy of 95.3% and to warn the user when their heart rate rises to an abnormal level.

Development of WMTS Module Based Pulse Rate Period Detection and Human Sensibility Evaluation System (WMTS 무선통신 모듈을 이용한 맥파의 주기검출 및 감성평가 시스템 개발)

  • Lee, Hyun-Min;Kim, Dong-Jun;Jeon, Ki-Man;Son, Jae-Gi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • In this study we present a system for pulse-rate period detection and human sensibility evaluation based on the wireless medical telemetry service (WMTS) used for transmission of data from medical telemetry devices to various medical facilities and services. We develop a medical-purpose specific WMTS communication module to transmit biometric signals. From the pulse rate variability(PRV) signal, we attempt to classify positive and negative emotional states based on analysis of the ratio of LF/HF in the frequency domain. We measure the data reception rate according to distance in order to test the performance of the WMTS module and analyze the effects on human sensibility evaluation.

Change of Heart Rate Variability on Menstruation in Women at College (여대생 월경(月經)의 심박변이도 변화에 대한 연구)

  • Kim, Gyeong Cheol;Kim, Yi Soon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.5
    • /
    • pp.745-752
    • /
    • 2012
  • This study aims to show the change of Heart Rate Variability(HRV) and Pulse wave velocity(PWV) on menstruation in women at college. Heart Rate Variability(HRV) and Pulse wave velocity(PWV) of 122 women at college were measured at their menstruation and ordinary period. SDNN, RMSSD, SDSD, HRV Index(%), stress resistance and cardiac activity were significantly higher at their menstruation than ordinary period, but Total Power and pNN50(%) were opposite. The automatic nervous system balance and physical stress were decreased in groups without dysmenorrhea than with one. PWV(E-R) and PWV(E-L) were much higher at menstruation than ordinary period. PTT(F-R) and PTT(F-L) were decreased in groups without dysmenorrhea than with severe one. We demonstrated that menstruation can effect on Heart Rate Variability and Pulse wave velocity and dysmenorrhea can cause the imbalance of autonomic nervous system.

40 GHz Pulse Train Generation by Spectral Filtering for Repetition Rate Quadruplication

  • Luan, Wanyong;Kang, Kyong-Tae;Seo, Dong-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.415-416
    • /
    • 2008
  • We demonstrate a simple method to multiply the repetition rate of an optical pulse train by a fiber Fabry-Parot interferometer (FFPI) spectral filtering. A stable 40 GHz pulse train at 1550 nm is successfully generated by removing unwanted spectral components of a 10 GHz actively mode-locked laser source by passing a high finesse FFPI.

  • PDF

A DELAYED SIR EPIDEMIC MODEL WITH NONLINEAR INCIDENCE RATE AND PULSE VACCINATION

  • Du, Yanke;Xu, Rui
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.5_6
    • /
    • pp.1089-1099
    • /
    • 2010
  • An SIR epidemic model with pulse vaccination and time delay describing infection period is investigated. The global attractiveness of the infection-free periodic solution is discussed, and sufficient condition is obtained for the permanence of the system. Our results indicate that a large vaccination rate or a short period of pulsing leads to the eradication of the disease.

A new algorithm of pulse generation and detection for UWB communication system (UWB통신 시스템을 위한 새로운 펄스생성 방법 및 수신 알고리즘)

  • 김건수;윤상훈;정정화;이경국
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.242-245
    • /
    • 2003
  • This paper introduces a new algorithm of pulse generation and detection for UWB communication system. The existing UWB systems using Gaussian pulse have some difficulties to cope with bandwidth limitation and frequency transition. Moreover. the system sensitivity to channel noise has made the processes of acquisition and tacking difficult. in this paper, we introduce a new pulse generation method which is able to control the bandwidth and center frequency applying modulation method. thus could improve the detection performance of receiving algorithm. Also, we made a system to search maximum perk by applying the proposed algorithm and consequently could guarantee the correct detection. By the result of simulation, when accumulate 10 times at every 2dB band shifting from 0 to 18dB on AWGN channel, we could confirm the proposed method has 97.4% PDR(Pulse Detection Rate) and 1.868% FAR(False Alarm Rate) performance at 4dB SNR and 15% transmission power threshold level.

  • PDF

High Repetition Rate Optical Pulse Multiplication with Cascaded Long-period Fiber Gratings

  • Lee, Byeang-Ha;Eom, Tae-Joong;Kim, Sun-Jong;Park, Chang-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.29-33
    • /
    • 2004
  • We propose and demonstrate a novel optical pulse multiplier applicable to OTDM (Optical Time Division Multiplexing) systems using cascaded long-period fiber gratings. We have exploited the fact that each mode in a fiber has a different propagation constant to obtain time delays among optical pulses. The proposed scheme could realize high-frequency optical pulse multiplication for optical short pulse trains. We have successfully implemented two, four, and eight times multiplications with the maximum repetition rate of 416.7 ㎓. The obtained pulse delays are well matched with the simulated ones.

PEO Film Formation Behavior of AZ31 Mg Alloy under Pulse Current (펄스 전류 하에서 AZ31 마그네슘 합금의 플라즈마전해산화 피막의 형성 거동)

  • Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.5
    • /
    • pp.292-298
    • /
    • 2022
  • In this study, PEO (plasma electrolytic oxidation) film formation behavior of AZ31 Mg alloy under application of 300 Hz pulse current was studied by the analyses of V-t curve, arc generation behavior, PEO film thickness and morphology of PEO films with treatment time in 0.05 M NaOH + 0.05 M Na2SiO3 + 0.1 M NaF solution. PEO films was observed to grow after 10 s of application of pulse current together with generation of micro-arcs. PEO film grew linearly with treatment time at a growth rate of about 5.58 ㎛/min at 200 mA/cm2 of pulse current but increasing rate of film formation voltage became lowered largely with increasing treatment time after passing about 250 V, suggesting that resistivity of PEO films during micro-arc generation decreases with increasing film formation voltage at more than 250 V.

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor (홀센서 집게형 맥진기 요골동맥파에 FFT를 적용한 호흡수 추출 연구)

  • Cho, Hyun-Sung;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.5
    • /
    • pp.178-182
    • /
    • 2012
  • This research suggested that the extraction of respiratory rate could be made possible by using frequency analysis in the data process for clip-type pulsimeter equipped with permanent magnet and Hall sensor. The pulse analysis included of cardiac motion information depending on variation of pulse waveforms is investigated by means of Fast Fourier Transformation (FFT). The peaks of FFT spectrums measured at 15, 20, 30, 40, and 50 tempos are coincided to each respiratory rate having 0.125 Hz, 0.16 Hz, 0.25 Hz, 0.33 Hz, and 0.41 Hz, respectively. The FFT spectrum using algorithm for the extraction of respiratory rate showed the best pulse waves measured during 300 s. Based upon these results, the clip-type pulsimeter could extract the effective respiratory rate reflecting physical effects.