• Title/Summary/Keyword: Pulse rate

Search Result 1,677, Processing Time 0.042 seconds

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

A Study of Effects on Secretion of Gastric Juice, Movement of Intestine and Pulse Rate with Coptidis Rhizoma and Zingiberis Rhizoma (황연(黃連) 및 건강(乾薑)이 위액분비(胃液分泌).장관운동(腸管運動) 심장박동(心臟搏動)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Yu, Gi-Won;Park, Dong-Won;Ryu, Bong-Ha;Gwak, Gi-Hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.3 no.1
    • /
    • pp.23-32
    • /
    • 1986
  • As a result of administration of Coptidis Rhizoma extract and Zingiberis Rhizoma extract to Rat and Rabbit, its effect to the Gastric Juice Volume, Acidity, Pepsin out put of Rat and the movement of Intestine, Pulse Rate of Rabbit was as follows; 1. In the secretion of Gastric Juice, the Juice Volume in Coptidis Rhizoma administered group in contrast to Control Group, has increased in 30mg the increasing rate 21.4%, and has decreased in 300mg the decreasing rate 113.9%. But the Juice Volume in Zingiberis Rhizoma administered group has all decreased in 12, 30, 60, 120mg, and has remarkably decreased in 60mg the decreasing rate 62.9%. 2. The Gastric Acidity in Coptidis Rhizome administered group, in contrast to Control Group, has increased in 30, and 75mg, but no significant value, and has decreased in 300mg the decreasing rate 104.7%. But the Gastric Acidity in Zingiberis Rhizoma administered group has all decreased in 12, 30, 60 120mg, and has remarkably decreased in 60mg the decreasing rate 105.6%. 3. The Pepsin out-put in Coptids Rhizoma administered group, in contrast to Control group, has increased in 30mg the increasing rate 30.3%, and has decreased in 150, 300mg, no significant value. But the Pepsin out-put in Zingiberis Rhizoma administered group has all decreased in 12, 30, 60, 120mg, and has remarkably decreased in 60mg the decreasing rate 86.4%. 4. In the movement of Intestine, the contraction Coptidis Rhizoma administered group, in contrast before the administration, has increased in 12mg, but has begun to decrease in 30mg, and has remarkably decreased in 70mg. The contraction in Zingiberis Rhizoma administered group, in contrast before the administration, has all increased in 30, 60, 120mg. 5. In Pulse Rate, the pulsation, in contrast to Control group after 60, 120 180, 240min. has decreased in Coptidis Rhizoma administered group, and has increased in Zingiberis Rhizoma administered group, but no significant value.

  • PDF

Ablation Rate and Intrapulpal Temperature by Addition of Water Spray During Er:YAG Laser Irradiation (Er:YAG laser를 이용한 치아삭제시 물분사량이 삭제율과 치수내 온도변화에 미치는 영향)

  • Kim, Jung-Moon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.375-381
    • /
    • 2005
  • Er:YAG laser has been considered a promising alternative to dental drill and many researches indicate that adjustment to variable parameters, including water flow rate, pulse energy and pulse repetition rate, can be made to improve ablation ability and efficiency of the laser. Of these parameters, addition of water spray during irradiation has been thought to ablate dental hard tissue more rapidly and safely. The purpose of this study was to investigate tooth ablation amount by Er:YAG laser irradiation as related to varied water flow rates added and, ultimately to find the most effective water flow rate for ablation. In addition, the temperature change of pulp chamber during irradiation was also monitored on the irradiated and opposite pulpal walls, respectively. An Er:YAG laser with contact mode was employed. Extracted human molars were split into two pieces for ablation experiment. Pulse energies of 200 and 300 mJ with a pulse repetition rate of 20 Hz and 5 water flow rates (1.6, 3.0, 5.0, 7.0, and 10.0 ml/min) were applied. Each irradiation was performed for 3 seconds. According to these parameters, experimental groups were divided into 10 subgroups which consisted of 5 specimens. For temperature experiment, another 5 tooth-specimens were prepared in the manner that pulp chamber was open through access cavity preparation and two temperature-measuring probes were placed respectively on the irradiated and the opposite walls of pulp chamber. From the experiment on ablation amount related to different water flow rates, it was shown that the least water flow rate of 1.6 ml/min ablated more than any other water flow rates (p<0.000). When the irradiation for 3 seconds, combined with the pulse repetition time of 20Hz and the water flow rate of 1.6 ml/min was done to tooth specimen, the temperature rise was not noticeable both on the irradiated and the opposite pulpal walls (less than 3$^{\circ}C$) and there was no significant difference in temperature rise between the two pulse energies, 200 and 300 mJ. From the results of this study, it is suggested that tooth ablation with Er:YAG laser can be done effectively and safely at a energy between 200 and 300 mJ/pulse and a pulse repetition rate of 20 Hz when the lasing is conjugated with the water flow rate of 1.6ml/min.

Laser application in 3-D micromachining (레이져를 이용한 3차원 형상가공에 관한 연구)

  • 윤경구;이성국;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.75-78
    • /
    • 1995
  • This paper presents the feasibility of laser ablation process in 3-D micro machining of MEMS (micro Electro Mechanical System)parts. The micro machining characteristics of polymer(Energy fluence, pulse repetition rate, number of pulse, ablation rate)are investigated and 3-D micro machined samples are demonstrated.

  • PDF

Measurement of workload by cardiac arrhythmia (부정맥을 이용한 작업부하의 평가)

  • 박영택;박경수
    • Journal of the Ergonomics Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 1983
  • While three subjects were running on treadmill at five different speeds, their heart beat interval times were measured and analyzed. From the analysis, we discovered some relation- ships between workload and cardiac response, especially cardiac arrhythmia. Using these relationships, a physioligical model for estimating workload was developed. Although pulse rate has been considered as a good measure of physical load, this study shows that it is highly subject dependent and therefore unsuitable for task evalution. It is recommended to use range of heart beat interval times rather than pulse rate in the evaluation of light work.

  • PDF

Unsteady Ignition in the Pulse Combustor with Counter Jet Flows (대향분출류가 있는 맥동연소기의 비정상 점화현상)

  • 이창진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An analytical study has been performed to investigate the unsteady ignition characteristics of pulse combustion. In many combustion applications, strain rate of the flow can significantly affect the combustion features; ignition, extinction, and reignition. In the pulse combustion, two jets (hot combustion gases and fresh mixtures) coming from the opposite side of the combustor will collide in the combustor forming a stagnation region where the chemical reaction is suppressed by the strain rate until this becomes below the critical value. In this research, the method of large activation energy asymptotic is adopted with one step irreversible kinetics to examine the ignition response to the periodic variation of the strain rate of flow. The results show the variation of the maximum value of strain rate can determine whether the ignition or extinction occur.

  • PDF

Performance Enhancement of SBC for Voice Signal Using Adaptive Postfiltering at the Medium Bit Rate (중간 전송율에서 적응 포스트 필터링을 이용한 음성용 SBC의 성능 향상)

  • 김원구;이남걸;윤대희;차일환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.2
    • /
    • pp.121-131
    • /
    • 1992
  • In this paper, three methods are studied to enhance the performance of SBC ( Sub-Band Coding )schemes for voice signal at the medium bit rate between 12 kbps and If; kbps, and adaptive postfilteritng using human auditory characteristics Is (Bone at the decoder out put. First, GQMF(Generalized Quadrature Mirror Filter ) Is used instead of QME'((Quadrature MirrorFiltcr ) to have better performance. Second, by adaptive bit allocation to each sub-band, speech quality is enhanced and valuable rate ceding If possible. Third, corriparlson study oS thr: coder performance using APCM(Adaptive Pulse Code ModulatioTi) and ADPCM( Adaptive Differentiai Pulse Code Modulatiori) , Indicates that SB AfCM performance better than the other. Adaptive postfiltering at the decoder output enhances the quality of the coded speech. The two proposed postfiltering methods decrease the noise sufficiently at the expense of the low computational load.

  • PDF

Changes in Oxygen-Pulse During Treadmill Walking (Treadmill 보행시 산소맥의 변화)

  • Lee, Chang-Hoon;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.281-287
    • /
    • 1984
  • In search for a method of evaluating the cardiopulmonary function. 74 male and 33 female volunteers ages $18{\sim}25$ were subjected to this study The subjects walked on a treadmill at speed of 2,4,6 and 8km/hr with 0,5,10,15,20 and 25% grade of inclination, respectively, for a measurement of heart rate and oxygen-pulse. Heart rate was measured every 5 seconds at resting state and during walking by telemetric method using Heart Checker 108 System (Senoh Co., Japan). Oxygen concentration was measured by Douglas bag method collecting expired air for 5 minutes at rest, and for 2 minutes at the end of each walking exercise. Oxygen concentration in an expired air was analyzed with Orzat gas analyser and expressed in terms of STPD. Oxygen-pulse was defined as an amount of oxygen consumed at every heart at a cellular level. The followings were the results obtained from this study. 1. Mean values of oxygen-pulse at resting state was $3.1{\pm}0.11ml/beat$ in male and $2.5{\pm}0.87ml/beat$ in female, respectively. 2. Mean values of oxygen-pulse during treadmill walking were increased in proportion with the load of exercise, namely, the speed and grade of inclination, from minimum of 7.1ml/beat upto maximum of 18.2ml/beat in male and from minimum of 4.2ml/beat upto maximum of 12,7ml/beat in female. 3. Both linear and logarithmic regressional relationships between oxygen-pulse and speed of walking and grade of inclination were observed in both sexes. Predicted values of oxygen-pulse by logarithmic regressional formula on speed and on grade of inclination were better coincided with the measured values than those predicted by the linear regressional formula.

  • PDF

Accuracy Analysis of Pulse Wave Sensor Data of Ear Label of Husbandry Livestock (축산 가축 이표용 맥파 센서의 데이터 정확도 분석)

  • Kim, Il-Gon;Kang, So-Hyung
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.387-393
    • /
    • 2014
  • In this research, we aimed to investigate the most optimum pulse wave sensor to ear label of live stocks among pulse wave piezo film sensor, conductive textile sensor, photo sensor. As a result of this research with application to 10 cattle, 10 pigs objects with pulse wave piezo film sensor, conductive textile sensor, photo sensor, photo sensor shows less standard deviation to average value than piezo film sensor or conductive textile sensor which means it is the most stable for the cattle. With pigs, piezo film sensor, conductive textile sensor and photo sensor all show stable pulse rate. Thus, to take pulse rate of livestock with curved body and long and dense coat such as cow, photo sensor will be considered as the most efficient mean.

A Study on Period Detection of Pulse Wave Using Wave Slopes (파형 기울기를 이용한 맥파 주기 검출에 관한 연구)

  • Lee, Hyun-Min;Kim, Dong-Jun;Kim, Kyeong-Seop;Lee, Jeong-Whan;Ahn, Ihn-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1978_1979
    • /
    • 2009
  • Heart rate may be a very important parameter in human health. To extract heart rate, the electrocardiogram(ECG) is commonly used. But the ECG acquisition procedure is somewhat complex. On the other hand, the acquisition of pulse wave or photoplethysmogram(PPG) is very easy. However, the peak of PPG is not so sharp as ECG. This study tries to enhance the performance of period detection in PPG signal. The method uses the average slopes around the main peak. The crossing point of the increasing and the decreasing slopes is selected as the peak point of heart rate period. The proposed method showed smoothed heart rate graph and reduced irregularity in heart rate values.

  • PDF