• Title/Summary/Keyword: Pulse rate

Search Result 1,676, Processing Time 0.034 seconds

KLYSTRON-MODULATOR SYSTEM PERFORMANCES FOR PLS 2-GeV LINAC (포항 20억 전자볼트 선형가속기 클라이스트론-모듈레이터 시스템의 성능)

  • Park, S.W.;Park, S.S.;Lee, K.T.;Oh, J.S.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1365-1367
    • /
    • 1995
  • The PLS 2-GeV linac employs 11 units of high-power pulsed klystrons(80MW) as the main RF sources. The matching modulators of 200 MW(400kV, 500 A) can provide a flat-top pulse width of 4.4 ${\mu}s$ with a maximum pulse repetition rate of 120 Hz at the full power level. For a good stability of electron beams, the pulse-to-pulse flat-top voltage variation of a modulator requires less than 0.5%. In order to achieve this goal, we stabilized high voltage charging power supplies within 1% by a phase controlled SCR voltage regulator. In addition, we employed ac/dc feedback together with a resistive De-Q'ing system to achieve far less than 0.5% variation of the PFN charging voltage. This paper presents the main feature of the klystron-modulator system and the characteristics of the pulsed high-power RF system performance during the beam injection operation for the Pohang Light Source commissioning.

  • PDF

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

AFM-based nanofabrication with Femtosecond pulse laser radiation (원자간력 현미경(AFM)과 펨토초 펄스 레이저를 이용한 나노 형상 가공)

  • Kim Seung-Chul;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.149-150
    • /
    • 2006
  • We describe a novel method of scanning probe nanofabrication using a AFM(atomic force microscopy) tip with assistance of Femtosecond laser pulses to enhance fabrication capability. Illumination of the AFM tip with ultra-short light pulses induces a strong electric field between the tip and the metal surface, which allows removing metal atoms from the surface by means of field evaporation. Quantum simulation reveals that the field evaporation is triggered even en air when the induced electric field reaches the level of a few volts per angstrom, which is low enough to avoid unwanted thermal damages on most metal surfaces. For experimental validation, a Ti: sapphire Femtosecond pulse laser with 10 fs pulse duration at 800 nm center wavelength was used with a tip coated with gold to fabricate nanostructures on a thin film gold surface. Experimental results demonstrate that fine structures with critical dimensions less than ${\sim}10nm$ can be successfully made with precise control of the repetition rate of Femtosecond laser pulses.

  • PDF

Literature Study for Categorizing Physical Properties of Face, Pulse, Skin and Voice Based on Health State of Sasang Constitutions (사상체질별 건강수준에 따른 맥상, 안면, 피부, 음성의 물리량 도출을 위한 문헌고찰연구)

  • Lee, Jae-Chul;Lee, Yu-Jeong;Kim, Ja-Euk;Kim, Sang-Kil;Kang, Nam-Sik;Kim, Jong-Yeol;Kim, Sang-Hyuk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.755-758
    • /
    • 2011
  • Sasang Constitutional Medicine (SCM) suggests the concept of health condition which is owned of different properties by each Sasang Constitution. But SCM theory has concentrate to explaining different symptoms that distinguish health condition, not much concerned with practical methods like face features, pulse diagnosis, skin surface properties and voice features. Physical properties of practical diagnosis methods from literature finding have been researched. As a result, complexion and face moisture were described to be physical properties related to health State. In scope of pulse diagnosis, depth, rate, contour, width and pressure are related. Skin surfaces' elasticity, moisture, fraction properties were also suggested as factors of health State of Sasang Constitution. We assume that this study would contribute further studies for objectifying and quantifying diagnosis methods to evaluate health state grades of Sasang Constitution.

RVOT Obstruction Caused by Projection of The Herniated Aortic Cusp Through Subpulmonic VSD (심실중격결손증에 속발한 대동맥판탈출에 의한 우심실유출로 협착 [1례 보고])

  • 이병우
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.254-259
    • /
    • 1981
  • This is a case of successfully surgically treated RVOT obstruction caused by projection of the herniated aortic cusp through subpulmonic supracristal VSD at Department of Thoracic and Cardiovascular Sugery, Hanyang University Hospital. The patient was a 17 year old boy. Congenital heart anomaly was suspected at 2 years of his age. He had palpitation, dyspnea on exertion and epistaxis for 2 years prior to admission to our hospital. On examination, the blood pressure was 170/0mmHg. And the pulse rate was 100/rain. Widening of pulse pressure, water hammer pulse [bounding pulse]. To and fro murmur and head nodding were noted. Cardiomegaly was seen in chest x-ray. EKG, Echocardiography, Cardiac catheterization and angiocardiography were performed. On April 27, 81. Open heart surgery was performed under the impression of VSD combined with AI. On Rt. ventriculotomy, we noticed RVOT obstruction caused by prolapsed rt coronary cusp through a VSD. The subpulmonic supracristal VSD measuring 2.5 x 3 Cm in diameter was closed with Teflon patch graft and then the prolapsed aortic leaflet was plicated by placing three 8-figure suture between the free edge and the base of the leaflet through transverse aortotomy. After operation, excellent result was obtained: B.P, was 110/50mmHg and any sign of AI or residual shunt was not found at discharge.

  • PDF

The Ion Generation Characteristics of Charge Neutralizer Applied a Pulse Voltage (펄스전압을 적용한 전하중화장치의 이온발생 특성)

  • Moon, Jae-Duk;Chung, Suk-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.140-146
    • /
    • 1998
  • Methods and systems to remove static electricity are requested necessarily because the static electricity causes a flammable gas explosion, a fire, reduction of production rate in manufacturing VLSI semiconductor device and so on. In this paper, abrasion and dust contaminant of needle electrode are studied experimentally. And, frequencies and pulse durations of a high frequency pulse source were controlled effectively to minimize the abrasion of needle electrode and control generated numbers of ions. As a result, it is verified experimentally that the ion generation of charge neutralizer increases by using a high frequency pulse source.

  • PDF

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

Theoretical Analysis of Impact of Q-switch Rise Time on Output Pulse Performance in an Ytterbium-doped Actively Q-switched Fiber Laser (이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석)

  • Jeon, Jinwoo;Lee, Junsu;Lee, Ju Han
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • A theoretical analysis of the impact of rise time of a Q-switch on the output pulse performance is carried out in an Ytterbium-doped actively Q-switched fiber laser. The finite difference time domain (FDTD) method is used to numerically simulate the Q-switched fiber laser. It is shown that stable Gaussian-like pulse shape can be generated when the Q-switch rise time is increased and pulse repetition rate is enlarged.

The Microbe Removing Characteristics Caused by Dirty Water Using a Simple Pulsed Power System

  • Kim, Hee-je;Song, Keun-ju;Song, Woo-Jung;Kim, Su-Weon;Park, Jin--Young;Joung, Jong-Han
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.91-95
    • /
    • 2004
  • The pulsed power system is widely available for use in pulse generator applications. Generally, the pulse generator is required for very short pulse width and high peak value. We have designed and fabricated our own pulsed type power system and through its use, we investigated microbe removal characteristics. This paper introduces a simple pulsed power system for removing various microbes caused by dirty water. This system includes a 2 times power supply circuit, IR2110 operated by using a fixed voltage regulator 7812 and 7805, and the switching MOSFET (Metal Oxide Semiconductor Field Effect Transistor). We can also control this process by using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various microbes by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

Characteristics of high-efficiency rust removal by adjusting variable frequency and voltage charging using the Pulsed Power system (펄스파워를 이용한 전압 및 주파수 가변에 의한 고효율 RUST (녹) 제거 특성에 대한 연구)

  • Song, Woo-Jung;Kim, Su-Weon;Jeon, Jin-An;Joung, Jong-Han;Kim, Hwi-Young;Kim, Hee-Je
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.180-183
    • /
    • 2002
  • The pulsed power system was widely making use good of many industrial and environments. The pulse generator generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, this system is designed and fabricated which has a compact size of pulse generator with switched MOSFET. We have studied the removal of rust material using Arc discharging. It have tested their characteristics by adjusting variable voltage charging and pulse repetition rate. As a result, We can eliminate rust materials with this device.

  • PDF