Development of the Collective Thomson Scattering System in KAERI

  • 박민;김선호;안찬용;김성규
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.521-521
    • /
    • 2013
  • Collective Thomson scattering (CTS) system is being developed in KAERI based on high power gyrotrons. CTS is a promising diagnostic method to measure fast ion distributions and potentially the fusion product alpha particles in magnetically confined plasmas. By utilizing millimeter-waves from high power gyrotrons as a probing beam, spatially and temporally resolved 1-D ion velocity distributions can be obtained from the scattered radiation with less scattering geometrical constraints. The pulse modulation of gyrotrons enables to separate scattering signal from ECE background noises. The feasibility was assessed with the calculation of spectral density functions under the condition of KSTAR plasmas. Further CTS system requirements are also discussed.

  • PDF

회전기 권선의 펄스 전송특성 연구 (A Study on the Partial Discharge Wave Propagation along Stator Winding)

  • 강동식;심우용;황돈하;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

침-평판 전극 구조에서 발생하는 기중 코로나 방전의 해석 기법 (Analysis Techniques of Corona Discharges in Air with Needle-Plane Electrode System)

  • 강성화;박영국;권순석;정수현;류부형;임기조
    • 한국안전학회지
    • /
    • 제11권4호
    • /
    • pp.49-53
    • /
    • 1996
  • Corona discharges in air insulated electric power systems cause power loss, produce interfering electromagnetic radiation, and can indicate incipient failure. An understanding of corona discharges in air gap is clearly Important. The Wavelet transformation is an extended method of fourier transformation. The fourier method is a powerful tool for signal analysis, but it can't include information for time. However the wavelet transformation analysis can include on the information of time and frequencies at the same time. In this paper we apply the wavelet transformation to the corona signals in needle-plane air gap for the purpose of analysis of developing aspects of corona discharges. We analyzed the developing aspects of corona discharges, namely, corona discharge current, repetition rates, width of Pulse distribution region, pulseless region and frequencies distribution of corona discharge pulses.

  • PDF

방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화 (Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation)

  • 신경철;이덕희;이관호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권4호
    • /
    • pp.466-473
    • /
    • 2000
  • 연구배경 : 수술로 절제하기 어려운 국소진행성 제3기 비소세포 암은 주로 방사선 치료 단독 혹은 방사선 치료와 전신 항암화학요법을 병행하게 된다. 이 두 치료 방법은 잠재적으로 폐 기능을 손상시킬 수 있으며 기존의 폐 기능을 더욱 악화시키게 된다. 저자들은 국소진행성 폐암환자들에 대하여 방사선 치료 전 후 안정시 폐 기능과 운동시 심 폐 기능을 동시에 평가하여 방사선 치료가 실제 운동부하 심 폐 기능에 미치는 영향을 평가하였다. 대상 및 방법 : 수술로 절제할 수 없는 편평상피세포암을 가진 남자 11명에 대하여 방사선 치료 전과 치료 후 4주에 각각 흉부 X-선 검사 및 안정시 폐 기능 검사 그리고 운동부하 심 폐 기능 검사를 시행하였다. 운동부하 심 폐 기능 검사로 운동능력과 심 혈관계기능, 환기기능, 그리고 가스교환기능에 대하여 측정하였다. 방사선 치료는 일일 1.8Gy로 일 주일에 5회 시행하여, 8주 동안 70Gy를 시행하였다. 결과 : 저자들의 연구로 방사선 치료 전 후 다음과 같은 결과를 얻었다. 1) 최대산소섭취량($VO_2$max), 이산화탄소생성량($VCO_2$), 운동지속시간 그리고 운동수행능력의 차이는 없었다. 2) 산소맥($O_2$ pulse) 및 심박동수, 그리고 예비심박동수(heart rate reserve)의 변화도 없었다. 3) 최대분당환기량(VEmax) 및 상시호흡량 그리고 예비호흡의 변화도 없었다. 4) 운동부하 심 폐 기능 검사 중 대부분의 환자는 호흡곤란과 다리근육의 피로로 더 이상 운동을 할 수 없었다. 5) 안정시 폐 기능 검사 결과 노력성 폐활량(FVC) 과 1초간 노력성 호기량($FEV_1$)의 변화는 없었으나 폐확산능(DLCO)은 치료 전 후 각각 85%, 74%로 약 11%의 감소가 있었지만 통계적으로 유의 하지는 않았다. 결론 : 방사선 치료 후 4주에 평가한 국소진행성 폐암환자의 운동부하 심 폐 기능 검사 결과 치료 전에 비하여 운동능력 및 심 혈관계기능, 환기기능, 그리고 폐포의 가스교환기능의 차이는 없었다. 결론적으로 폐암환자는 방사선 치료 후 운동부하 심 폐 기능의 저하는 단기간 내 일어나지 않는 것으로 생각된다.

  • PDF

가변 커버리지를 갖는 위성 관제용 접이식 헬리콘 반사체 안테나 성능 연구 (Modified Fold Type Helicone Reflector for Efficient Satellite TT&C Having Variable Coverage Area)

  • 이상민;이우경
    • 한국전자파학회논문지
    • /
    • 제20권9호
    • /
    • pp.914-923
    • /
    • 2009
  • 헬릭스 안테나는 관제, 관측, 탐사, 통신 위성 등에서 관제(TT&C), 데이터 통신, GPS 수신 시스템, 전술 시스템으로 활용되고 있다 위성의 Z축에서 최대 지향성과 방사 특성을 갖는 헬릭스는 광대역의 임피던스와 통신 커버리지 대역을 제공할 수 있다. 도파관 혼 구조는 흔히 레이다 분야에 이용되는데, 지반 탐사 레이다 및 전자파 장애 측정 등 초 광대역 펄스를 필요로 하는 곳에 사용된다. 또한 크기가 비교적 작고, 적은 방사 왜곡으로 인한 고효율과 낮은 반사 특성을 갖는 장점이 있다. 본 논문에서는 고용량의 데이터를 전송하여 넓은 주파수 대역폭을 사용하는 통신 및 원격 탐사 위성에 적합한 도파관 혼-헬릭스 결합 안테나를 설계한다. 설계된 변형 구조 안테나는 S 밴드에서 가변 빔 스캐닝 모드를 갖는 혼-헬릭스 결합 헬리콘 구조로 관제, 탐사, 고속 데이터 통신용 등의 다기능 안테나로 동작한다. 도파관 혼은 테이퍼된 헬릭스를 감싸는 접이식 반사체로 설계하여 구조물의 소형화를 유도한다. 현재 개발 중인 차세대 다목적 실용위성에서는 고성능의 탑재체를 활용하기 때문에 정밀하고 안정된 위성 자세 제어 능력을 요구하고, 위성 안테나의 지향성 요구 조건이 강화된다. 이를 위해 설계된 안테나의 위성 초기 배치에 따른 링크 분석을 통해 위성체의 자세 및 운용 모드에 따라 다른 결과를 갖는 빔 스캐닝을 산출하고 각 모드에서의 자료 전송률에 대해 연구한다.

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성 (Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application)

  • 강동헌;채미나;홍세원
    • 한국전기전자재료학회논문지
    • /
    • 제29권8호
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Initial Dosimetry of a Prototype Ultra-High Dose Rate Electron-Beam Irradiator for FLASH RT Preclinical Studies

  • Hyun Kim;Heuijin Lim;Sang Koo Kang;Sang Jin Lee;Tae Woo Kang;Seung Wook Kim;Wung-Hoa Park;Manwoo Lee;Kyoung Won Jang;Dong Hyeok Jeong
    • 한국의학물리학회지:의학물리
    • /
    • 제34권3호
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: FLASH radiotherapy (RT) using ultra-high dose rate (>40 Gy/s) radiation is being studied worldwide. However, experimental studies such as preclinical studies using small animals are difficult to perform due to the limited availability of irradiation devices and methods for generating a FLASH beam. In this paper, we report the initial dosimetry results of a prototype electron linear accelerator (LINAC)-based irradiation system to perform ultra-high dose rate (UHDR) preclinical experiments. Methods: The present study used the prototype electron LINAC developed by the Research Center of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Korea. We investigated the beam current dependence of the depth dose to determine the optimal beam current for preclinical experiments. The dose rate in the UHDR region was measured by film dosimetry. Results: Depth dose measurements showed that the optimal beam current for preclinical experiments was approximately 33 mA, corresponding to a mean energy of 4.4 MeV. Additionally, the average dose rates of 80.4 Gy/s and 162.0 Gy/s at a source-to-phantom surface distance of 30 cm were obtained at pulse repetition frequencies of 100 Hz and 200 Hz, respectively. The dose per pulse and instantaneous dose rate were estimated to be approximately 0.80 Gy and 3.8×105 Gy/s, respectively. Conclusions: Film dosimetry verified the appropriate dose rates to perform FLASH RT preclinical studies using the developed electron-beam irradiator. However, further research on the development of innovative beam monitoring systems and stabilization of the accelerator beam is required.

인체 부착용 방사패턴 재구성 안테나의 SNR 및 BER 성능 분석 (Performance analysis of SNR and BER for radiation pattern reconfigurable antenna)

  • 이창민;정창원
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4125-4130
    • /
    • 2015
  • 본 논문은 생체신호 (체온, 혈압, 맥박 등)를 측정하는 웨어러블 (Wearable) 디바이스에 장착된 인체 부착용 방사패턴 재구성 안테나의 통신성능 비교에 관한 논문이다. 제안된 안테나의 동작주파수는 블루투스 (Bluetooth) 통신 대역의 2.4 - 2.5 GHz 이며, 안테나의 최대이득은 1.96 dBi 이다. 제안된 안테나는 두 개의 RF 스위치 (PIN diode)를 이용하여 서로 반대방향의 빔을 생성하여 전자기파 신호를 효율적으로 송수신 한다. 또한 제안된 안테나는 탑 로딩(Top Loading)을 이용 세 가지의 각도 변경 ($30^{\circ}$, $90^{\circ}$, $150^{\circ}$)을 통해 각 방사패턴의 지향성 변화를 조사 하였다. 본 논문에서는 방사패턴 재구성 안테나를 통해 전파 간섭이 없는 전자파 차페실의 이상적인 전파환경과 실제 전파간섭이 존재 (Universal Software Radio Peripheral, USRP)하는 스마트 하우스 내에서 웨어러블 디바이스 안테나의 신호대 집음비 (Signal-to-Noise Ratio, SNR) 및 비트 에러율 (Bit Error Rate, BER) 성능 측정을 진행하였다. 두 경우의 측정 비교 시 SNR은 평균적으로 5 dB의 성능저하를 보이며, BER은 최대 10배 증가하여 수신 에러율 (Error rate of receiving signal)이 높아지는 것을 확인하였으며, 본 논문에서 측정한 SNR과 BER의 측정 결과로 전자파기기의 방해전파로 인한 성능저하를 수치상으로 예측 하였다.

Statistical Properties of Electric Fields Produced by Cloud-to-Ground Lightning Return Strokes

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Seung-Chil;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권4호
    • /
    • pp.120-126
    • /
    • 2001
  • For the past five years, Inha University has been observing the electric fields produced by cloud-to-ground return strokes. This paper presents the summary of most recent results. Statistics on the zero-to-peak rise time, the zero-to-zero crossing time and the amplitude ratio of the second peak in the opposite polarity to the first peak were examined. The radiation electric fields produced by distant cloud-to-ground return strokes were substantially same pattern. The first return stroke field starts with a slowly increasing front and rises abruptly to peak. The rising portions of the electric fields produced by cloud-to-ground return strokes last 1 $mutextrm{s}$ to a few $mutextrm{s}$. The mean values of the zero-to-peak rise times of electric fields were 5.72 $mutextrm{s}$ and 4.12 $mutextrm{s}$ for the positive and the negative cloud-to-ground return strokes, respectively. The mean of the zero-to-zero crossing time for the positive return strokes was 29.48 $mutextrm{s}$ compared with 38.54 $mutextrm{s}$ for the negative return strokes. The depths of the dip after the peak of return stroke electric fields also have the dependence on the polarity of cloud-to-ground return stroke, and the mean values for the positive and negative cloud-to-ground return strokes were 33.55 and 28.19%, respectively.

  • PDF