• Title/Summary/Keyword: Pulse pressure

Search Result 1,215, Processing Time 0.032 seconds

Development of RF Stimulating Protocol for Effective Heat-Stimulus in Subcutaneous Tissue (피하에 효과적인 열 자극을 위한 고주파 자극 프로토콜 개발)

  • Myoung, Hyoun Seok;Lee, Dae Won;Kim, Han Sung;Lee, Kyoung Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.194-201
    • /
    • 2012
  • Moxibustion is utilized not only to cure disease but also to increase immunity. However, it may lead to undesired effects including severe pains(blisters and burns) because of the difficulty of controlling heat intensity. To overcome these problems we developed the RF heat stimulation system which can control stimulus. Also, we developed the RF stimulation protocol for effective heat transfer in subcutaneous tissue of rabbit. RF stimulator consists of a medical RF capacitive heating device, isolation probe, isolation plate, negative pressure control part and temperature measurement part. For the designed stimulus protocol, we measured the temperature distribution on epidermis and in subcutaneous(5mm, 10mm) area of rabbit during moxibustion. A stimulation protocol was designed by controlling the ON/OFF duty ratio, repeating number, and energy of applied pulse to get the temperature distribution similar with that by moxibustion. In results, the correlation coefficients between temperature distribution by moxibustion and that of stimulator were 95% and 91% from 5mm and 10mm thick respectively. However, temperature distribution on epidermis by stimulator was remarkably lower than that of the moxibustion. Finally, the RF stimulation system showed that it can not only transfer effectively heat similar with moxibustion to the subcutaneous area, but also the influence by unwanted side effects can be minimized.

The Healing Effects of Concentration Meditation(CM) on Mind-Body - Focusing on Meditation of Dhammakaya Temple - (집중명상(Concentration Meditation:CM)이 심신치유(心身治癒)효과에 미치는 영향 -태국 담마까야(Dhammakaya)사원 명상법 중심으로-)

  • Seo, Byung-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.534-546
    • /
    • 2020
  • The purpose of this study is to prove the positive effect of mind and body healing through the modified meditation method of Southern Buddhism as a systematic practice to concentrate or empty consciousness of the Buddhist temple in Dhammakaya, Thailand. To investigate the effects of the program on the participants, the experimental measurement tools in this study include the Immeasurable scale, spirituality scale, simple mental test scale, and blood pressure scale, pulse meter, thermometer, and recorder. When the measured values were compared with the corresponding t-test, there were some differences before and after the measurements based on the significance probability p <0.05. As a result, there was a significant correlation between spiritual support scale and the Immeasurable scale. In addition, the results of analyzing the data through interviews showed that the body and physiologically effective concentration was well after the meditation experience, and the intention to actively utilize this meditation method was confirmed. In this study, it was confirmed that there was a positive effect of the Samata practice method of Concentration meditation(CM), and thus the theoretical and experimental effects of intensive meditation were presented. I hope that these studies will accumulate and follow-up studies will be conducted through intensive meditation as a healing effect.

An Experimental Study on Physiological and Psychological Effects of Pine Scent (소나무 향기의 생리 심리적 효과에 관한 실험적 연구)

  • Jo, Hyun-Ju;Fujii, Eijiro;Cho, Tae-Dong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.1-10
    • /
    • 2010
  • The scientific verification of the physiological and psychological effects that result from interaction with green plants would not only provide objective knowledge on the psychological effect of green but would also establish useful grounds for the creation of green spaces that consider human emotions. The present study measured the cerebral activity(cerebral blood flow) and the autonomic nervous system activity (blood pressure, pulse rate, amylase) of fifteen Korean male subjects as they inhaled the natural scent diffused by pine needles. Impression and mood state evaluations of the reactions to the pine scent were carried out using the SD method and POMS. Cerebral activity was observed to be significantly activated in the feeling, judgment, and motor areas of the frontal lobe, as well as the memory area in the temporal lobe. Verbal evaluations by the SD method and POMS indicated a pine scent left natural but stimulated and active impressions, provided vigor, and also reduced confusion. The autonomic nervous system activities, however, showed no significant differences. These findings verified scientifically that a pine scent vitalizes humans both physiologically and psychologically. These results could be useful as fundamental data for the design of green spaces that consider human emotional aspects.

Bio-Signal Detection Monitoring System Using ZigBee and Wireless Network (ZigBee와 무선 네트워크를 이용한 생체신호 검출 모니터링 시스템)

  • Kim, Kuk-Se;Bang, Sun-Kwang;Lee, Jeong-Gi;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.477-481
    • /
    • 2007
  • The emergency patient who occurs from the place where it is various the control which is quick must come to accomplish in Ubiquitous environment. In the body of the patient or the old person the organism signal sensor about under attaching condition of the patient at real-time about under the monitor ring about under disposing the control which is quick against the emergency patient does to become accomplished at the case real-time when the above will get in the body of the patient or the old person. Using ZigBee (802.15.4) system base on Shor wireless communication protocol because of complement wireless of hospital. This system use ZigBee (802.15.4) system to get for electrocardiogram, blood pressure and pulse bio-sensors. This paper constructs Bio-Sensor communication monitoring system and transmission rate and the delay which it follows possibility and node occurrence rate of wireless sensor network construction hour transmission session it leads and it verifies the effectiveness.

  • PDF

The Study on the Sweating Responses of Adult Female according to Garment types (의복형태에 따른 성인여성의 발한반응에 관한 연구)

  • Yeom Hee Gyong;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.4 s.44
    • /
    • pp.405-416
    • /
    • 1992
  • This study was performed to investigate correlation between total body weight loss and local sweat rate and to find out any possible method that can estimate total body weight loss judging from local sweat rate. Twelve adult females were kept at 44 $\pm1^{\circ}C$, 50 ${\pm}5\%$ R.H. (1) Physiological responses such as total body weight loss, local sweat rate, rectal temperature, skin temperature, blood pressure and pulse, (2) micro climate inside garment and (3) subjective sensation were examined. Two types of garment such as long-sleeves with long pants (Type I) and half·sleeves with short pants (Type II) were used to observe the effect of garment types on sweating response. Both clothing weight was equal (132$\pm$3 g/$m^{2}$). The results were as follows: 1. Regardless of the different types, total body weight loss was more interrelated with the sweat rate on forehead than any other parts of the body. Except the forehead, different parts of body with different types of garment influenced on body weight loss quite differently. 2. Total body weight loss was more interrelated with the weight gain of garment than the local sweat rate. 3. Under the environment of 44$\pm1^{\circ}C,\;50{\pm}5\%$R.H., body weight loss during 1 hour of subject clothed and silted was 275.2 g/hr and weight loss per body surface area was 178.9 g/$m^{2}/hr$ Garment types have no influences on total body weight loss. 4. Local sweat rate (mg/7.07 $cm^{2}/hr$) was 208.0,191.0, 133.0, 115.0,81 0, 75.1 and 66.3 on scruff, breast, forehead, forearm, thigh, upper arm, leg respectively No evidence has been found that garment types influenced on local sweat rate (p<0.1). 5. No interrelationships between rectal temperature and total body weight loss, local skin temperature and total body weight loss, and local skin temperature and local sweat rate were found. From this study, some possible method that we can estimate total body' weight loss judging from weight loss of garment. But considering the fact that clothing design factor, the physical characteristics of fabric and environmental factor such as humidity and wind velocity should be concerned in weight loss of garment, it should be studied further whether the total body weight loss can be estimated properly from the weight loss of garment. This experiment suggest that different parts of body with different types of garment can influence on body weight loss quite differently. Therefore, in order to get more precise results, more studies under the diversity of garment types should be done in the near future.

  • PDF

A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House (Vinyl House 내의 환경조건과 인체적응에 관한 실험연구)

  • Shim, Bu-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

ARC Discharge Sound Source in Underwater (수중 아-크 방전음원에 관한 연구)

  • Chang, Jea-Hwan;Chang, Jee-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.12-18
    • /
    • 1985
  • In general the impulse sound sources of underwater generated by electric arc discharge had used static energy of the charged capacitors. The author proposed an underwater arc discharge sound source using secondary voltage of high voltage transformer without capacitors. The arc discharge device was composed of a high voltage transformer and a switching system. The impulse current in the primary turn of the high voltage transformer is controlled by the switching system and inductive current of the secondary turn in the high voltage transformer is used in making impulsive arc discharge. A series of experiment have been carried out to observe the acoustic characteristics of the impulse sound source generated by the arc discharge. The results obtained were as follows: 1. Secondary current at the time of arc discharge keeps after ohm's law in the beginning and the maximum current flows out as soon as arc discharge breaks out. 2. A time difference between a start of applied current and a generation of arc discharge sound is the 3msec and it is generated arc sound when breaking down electric insulation at maximum voltage. 3. The sharper the end of electrodes and the higher the secondary voltage, the higher the sound pressure level. 4. Arc discharge sound was generated even at the distance of 100cm between electrodes and was stably reproductive at the gap of 1cm to 100cm. 5. Electric arc discharge sound wave is a shock wave of pulse-width of 0.15msec and spectral distribution of it is plenty of low frequency components less than 10 KHz.

  • PDF

A Clinical Study on $^{125}I\;T_3$ Resin Uptake Rate and Serum Thyroxin ($T_4$) in Hyperthyroidism (갑상선기능항진증(甲狀腺機能亢進症)에 있어서 $T_3RU$$T_4$에 관(關)한 임상적(臨床的) 연구(硏究))

  • Moon, Ern-Soo;Park, Yoh-Han;Cho, Chang-Ho;Park, In-Soo;Lee, Chong-Suk;Lee, Hak-Choong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.12 no.2
    • /
    • pp.23-31
    • /
    • 1978
  • Hyperthyroidism may be defined as those clinical conditions which result from an increase in the circulating levels of one or both thyroid hormones. Hyperthyroidism in broad sense could be classified with toxic diffuse goiter, toxic adenomatous goiter, and toxic multinodular goiter on the basis of the circulating thyroid hormone levels. For this study, the subject included 94 cases with hyperthyroidism were presented in 77 with toxic diffuse goiter, 8 with toxic adenomatous goiter, and 9 with toxic multinodular goiter on the levels of $^{125}IT_3$ resin uptake rate and serum thyroxine ($T_4$). The observed results were as follows: 1) In the cases of hyperthyroidism including toxic diffuse goiter, toxic adenomatous goiter, and toxic multinodular goiter, 20.21% of the patients were male and 79.79% female. The majority of the patients were in 2nd to 4th decades of their lives. 2) There were objective signs clearly manifested in hyperthyroidism including toxic diffuse goiter and toxic adenomatous goiter which were rare in the multinodular goiter. The clinical signs in toxic diffuse and toxic adenomatous goiter included wide pulse pressure, tachycardia, systolic murmur, exophthalmos, tremor and warm skin etc. (Table 3.) 3) The most freauent complaints of the patients with hyperthyroidism were palpitation, weight loss, increased appetite, perspiration, heat intolerance, nervousness, exertional dyspnea, and menstrual disturbance etc. (Table 4.) There was no clear difference in the incidence of symptoms between toxic diffuse goiter and toxic adenomatous goiter, but there was clear difference between toxic multinodular goiter. 4) Considering of results of $^{125}IT_3$ resin uptake rate and serum $T_4$ level in toxic diffuse goiter, toxic adenomatous goiter and toxic multinodular goiter, $^{125}I\;T_3$ resin uptake rate was $49.15{\pm}9.94%$ (mean) and serum $T_4\;21.29{\pm}7.04ug/dl$ (mean) in toxic diffuse goiter. In toxic multinodular goiter, $^{125}I\;T_3$ resin uptake rate was $32.47{\pm}6.74%$ (mean) and serum $T_4$ level $11.03{\pm}5.0ug/dl$, and then there was clear difference in the results of $^{125}I\;T_3$ resin uptake rate and serum $T_4$ between toxic diffuse goiter and toxic multinodular goiter. The levels of $^{125}I\;T_3$ resin uptake rate and serum $T_4$ in toxic adenomatous goiter were $40.32{\pm}13.08%$ (mean), $15.47{\pm}8.25ug/dl$ (mean) respectively, so there was no clear difference between toxic diffuse goiter and toxic adenomatous goiter. 5) There was no significant differnece in length and width performed with thyroid scanning in toxic diffuse goiter, toxic adenomatous goiter, and toxic multinodular goiter.

  • PDF

Clinical Study of Continuous Cervical Epidural Anesthesia with Bupivacaine (Bupivacaine 주입에 의한 지속적 경부경막외마취의 임상적 연구)

  • Gil, Seon-Hee;Hwang, Kyung-Ho;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.20-27
    • /
    • 1988
  • Continuous cervical epidural anesthesia with two different concentrations of bupivacaine had been performed in 43 cases for surgery of upper extremity and cervical spine. After the initial dose of 0.33% bupivacaine 15ml to Group I(n=22) and 0.5% bupivacaine 15ml to Group II(n=21) was injected respectively, we observed the circulatory and pulmonary functions to be changed, and evaluated the duration of those analgesic action. The number of spinal segment to be affected and the complications were checked. Statistical significance of changes after the initial dose in both groups was determined by student's t-test. All values are impresed as mean$\pm$1S.D.. The results were as follows: 1) Circulatory functions; Systolic B.P. and Pulse rate were decreased by 10~15torr and 5~6 beats per minute respectively between 10~30 minutes following the initial dose, which were statistically significant in both groups. 2) Pulmonary functions; The diminution of minute volume showed to 20% and a rise of $PaCO_2$ level to 5~6 torr respectively between 30~60 minutes following the initial dose, which were statistically significant in both groups. There were no significant changes in self respiration and respiratory rate in both groups. 3) The duration of analgesic action was $72.3{\pm}25.7$(min) in Group I and $83.5{\pm}28.5$(min) in Group II which was not statistically significant between two groups, and the number of affected spinal segment at ore hour following the Anesthusia was $8.7{\pm}2.0$ in Group I and $10.5{\pm}2.4$ in Group II which was statistically significant between two groups. 4) Complications; a. Hypotension(below 80torr in systolic pressure) was appeared in 5% of all patients. b. Bradycardia(below 60 beats per minutes) was appeared in 25% of all patients. c. Inadvertent dural puncture was developed in only one patient, In conclusion, the 0.33% bupivacaine as well as 0.5% bupivacaine were enough for those analgesic effect in the above mentioned surgery even though the duration of analgesic action was about 10 minutes shorter in Group I than that of Group II. The cardiopulmonary function was clinically rather stable in Group I than that of Group II. Therefore we thought 0.33% bupivacaine was satisfactory for the clinical practicality in the cervical epidural anesthesia.

  • PDF

Study on Absorption Characteristics of $CO_2$ in Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 이산화탄소 흡수특성 연구)

  • Oh, Sang-Kyo;Rhee, Young-Woo;Nam, Sung-Chan;Yoon, Yeo-Il;Kim, Young-Eun
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.241-246
    • /
    • 2008
  • Increase of $CO_2$ by using fossil fuels makes mainly global warming and the international efforts to reduce the $CO_2$ emission is being promoted. Absorption process using aqueous alkanolamine solution to remove acid components in the mixed gases has been used commercially. This method was used to remove $CO_2$ in the flue gas in recent years. $CO_2$ Absorption characteristics of several aqueous alkanolamine solutions such as MEA, DEA and AMP was studied by measuring vapor-liquid-equilibrium(VLE) and absorption velocity in this study. VLE measuring equipment, shell and reactor type, was used to acquire VLE data, equilibrium $CO_2$ pressure(${P_{CO_2}}^*$) and time at each pulse gas input. We also acquired the $CO_2$ absorption velocity by measuring the time to arrive the VLE at $40{\sim}80^{\circ}C$ and first gas input. The $CO_2$ absorption capacity of MEA 10wt% solution was higher than two alkanolamine solutions at $40^{\circ}C$ and the equilibrium $CO_2$ loading was 0.5. Absorption capacity was excellent as follows; AMP>DEA>MEA. But absorption velocity was fast as follows; MEA>AMP>DEA. Though good absorbent was considered by many variables, absorption velocity and capacity was more important factor.