• Title/Summary/Keyword: Pulse injection

Search Result 246, Processing Time 0.025 seconds

The Weldability of Aluminum Ball in Electrolyte Injection Hole by Nd:YAG Laser (리튬이온전지의 전해액 주입구 볼에 대한 Nd:YAG 레이저 용접성)

  • Kim, Jong-Do;Yoo, Seung-Jo;Kim, Jang-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.740-745
    • /
    • 2006
  • This study suggested the occurrence source of weld-defects and its solution methods in a welding of Electrolyte injection hole by pulsed Nd:YAG laser. In experiment, the ramp down was used in order that solidification crack was removed. Furthermore. shrinkage stress and heat input were reduced by changing of weld trajectory and defocused distance. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained. In conclusion this show that the welding stability is greatly affected by modulation of laser pulse shape for the same laser energy and welding parameters.

Hot-Carrier-Induced Degradation in Submicron MOS Transistors (Submicron MOS 트랜지스터의 뜨거운 운반자에 의한 노쇠현상)

  • 최병진;강광남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.7
    • /
    • pp.780-790
    • /
    • 1988
  • We have studied the hot-carrier-induced degradation caused by the high channel electric field due to the decrease of the gate length of MOSFET used in VLSI. Under DC stress, the condition in which maximum substrate current occures gave the worst degradation. Under AC dynamic stress, other conditions, the pulse shape and the falling rate, gave enormous effects on the degradation phenomena, especially at 77K. Threshold voltage, transconductance, channel conductance and gate current were measured and compared under various stress conditions. The threshold voltage was almost completely recovered by hot-injection stress as a reverse-stress. But, the transconductance was rapidly degraded under hot-hole injection and recovered by sequential hot-electron stress. The Si-SiO2 interface state density was analyzed by a charge pumping technique and the charge pumping current showed the same trend as the threshold voltage shift in degradation process.

  • PDF

A Study on the Event Processing for Electronic Control (전자제어의 Event 처리방법에 관한 연구)

  • 이종승;이중순;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.115-122
    • /
    • 1998
  • For digital engine control timings, such as ignition, are based on the crank shaft angle. Therefore, it is very important that the angle of the crank shaft can be detected with accuracy for optimal ignition timing. Sequential multi-point injection(MPI) systems that have independent injection events for each cylinder, are used to inject an accurate quantity of fuel, and to cope with varying engine status promptly. In this study the distributorless ignition timing. A crankshaft position sensor has been installed such that it generates a number of pulses per crankshaft revolution to permit accurate detection of the crank shaft angle. An event detecting algorithm has been developed, which detects the crank shaft pulses generated by the position sensor, and the software outputs the required control signals at given crank angle values. We clarified that the hardware method is the best way to increase the performance of the control system, because the event detecting duration T(1+2)max becomes zero.

  • PDF

Analysis of Biosignal Variations caused by Epidural Anesthesia (경막외마취에 따른 생체신호 변화의 분석)

  • 전영주;임재중
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2001
  • This study was performed to extract and analyze the biosignals to find the relationship between the level of anesthesia and the variations of physiological parameters during epidural anesthesia. Seven male and twenty female patients(ages from 45 to 70 years old) were participated for the experiment, and ECGs, PPGs, SKTs, SCRs were obtained during anesthesia. As results, the HF/LF ratios of HRV were decreased after the injection anesthetics. For skin temperatures, values measured from the palm was reduced and the temperatures from four channels, measured from armpit through the right side of the body, were increased. SCRs were decreased for all channels after the injection of anesthetics. However the heart rate and PPGs showed no significant changes. It was concluded that the injection of anesthetics result the changes in biosignals, and it could be explained by the degree of the sympathetic and/or parasympathetic nerve activities. Results of this study could provide the valuable information for the estimation of level for the spinal and general anesthesia, and could be extended to the development of a system which could quantify the level of anesthesia.

  • PDF

Effects of Distraction using Balloon Art on Pain during Intravenous Injections in Preschool Children (풍선 아트를 이용한 관심 전환이 학령전기 아동의 정맥 주사 삽입 시 통증에 미치는 효과)

  • Koo, Hyun-Young;Lim, Jung-Hae;Park, Ho-Ran
    • Child Health Nursing Research
    • /
    • v.13 no.1
    • /
    • pp.66-72
    • /
    • 2007
  • Purpose: This study was done to evaluate the effects of distraction using balloon art on pain experienced by preschool children when undergoing an intravenous injection. Methods: Participants were 40 hospitalized preschool children. Children in the experimental group (20) were distracted by balloon art while undergoing an intravenous injection. Children in the control group (20) received regular care. Pain experienced by the children was measured using self-report, observation tools, heart rate and oxygen saturation. The data were analyzed using the SAS program. Results: Compared with the control group, children in the experimental group showed significant difference in pain as shown by pulse rate. However, children in the experimental group did not show a decrease in pain in the self-report or behavior observation when compared with children in the control group. Conclusion: Distraction using balloon art can be used to reduce pain for preschool children when undergoing an intravenous injection. Further nursing interventions need to be developed and provided to preschool children when undergoing painful procedures.

  • PDF

Changes of Pituitary Hormones after Injection of Naloxone in the Hypotensive Phase of Korean Hemorrhagic Fever (한국형 출혈열 저혈압기에서 Naloxone 투여후 뇌하수체 홀몬의 변동)

  • Lim, Sang-Moo;Cho, Bo-Youn;Lee, Hong-Gyu;Lee, Jung-Sang;Koh, Chang-Soon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.79-84
    • /
    • 1986
  • The opiate antagonist, naloxone, was injected for the reversal of hypotension due to Korean hemorrhagic fever, and the authors observed changes in pituitary hormones. In the hypotensive phase of the Korean hemorrhagic fever, the f-endorphin was high, and normalized granually in the diuretic and convalescent period. The naloxone raised the pulse rate and the blood pressure within 30 minutes without change in the central venous pressure. Around 30 minuted after the injection of the naloxone, the $\beta-endorphin$, ACTH and cortisol rose. The prolactin fell down 60 minutes after the naloxone injection.

  • PDF

Comparison on Spray Characteristics of Diesel HEV Injectors for 3-different Driving Type (SI, PI, DPI) (3개 구동방식(SI, PI, DPI)별 디젤HEV용 인젝터의 분무 특성 비교)

  • Chung, M.C.;Sung, G.S.;Kim, S.M.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • Performance of DI diesel engine with high-pressure fuel injection equipment is directly related to its emission characteristics and fuel consumption. So, the electro-hydraulic injector for the common-rail injection system should be designed to meet the precise high fuel delivery control capability. Currently, most high pressure injector in use has a needle driven by the solenoid coil energy or the piezo actuator controlled by charge-discharge of output pulse current. In this study, macroscopic spray approaching method was applied under constant volume chamber to research the performance of three different injectors : solenoid, indirect-acting piezo and direct-acting piezo type for CR direct-injection. LED back illumination for Mie scattering was applied on the liquid spray visible of direct-acting piezo injector, including hydraulic-servo type solenoid and piezo-driven injectors. As main results, we found that a direct-acting piezo injector had better a spray tip penetration than hydraulic-servo injectors in spray visualization.

SELF-PULSATION CHARACTERISTICS OF A SWIRL COAXIAL INJECTOR WITH VARIOUS INJECTION AND GEOMETRIC CONDITIONS

  • Im, Ji-Hyuk;Kim, Dong-Jun;Yoon, Young-Bin;Bazarov, V.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.29-37
    • /
    • 2005
  • The spray and acoustic characteristics of a gas/liquid swirl coaxial injector are studied experimentally. The self-pulsation is defined as a pressure and flow rate oscillations by a time-delayed feedback between liquid and gas phase. Self-pulsation has strong influences on atomization and mixing processes and accompanies painful screams. So. the spray and acoustic characteristics are investigated. Spray patterns are observed by shadow photography technique in order to determine the onset of self-pulsation. And self-pulsation boundary with Injection conditions and recess length is get. To measure the frequency of the spray oscillation. oscillation of the laser intensity which passes through spray is analyzed by Fast Fourier Transform. For acoustic tests, a PULSE System was used. Acoustic characteristics of a swirl coaxial injector are investigated according to the injection conditions. such as the pressure drop or the liquid and gas phase. and injector geometries. such as recess length and gap size between the inner and outer injector. Front the experimental results. the increase of recess length leads to the rapid increase of the sound pressure level. And as the pressure drop of the liquid phase increases. the frequency of the self?pulsation shifts to the higher frequency. The frequency of spray oscillations is the same as that of the acoustic fields by self-pulsation.

  • PDF

Initial Rotor Position Estimation Method for IPMSM using Swtiching Frequency Pulse Voltage Injection (스위칭 주파수의 펄스 전압 주입을 이용한 IPMSM의 회전자 초기 위치 추정)

  • Park, N.C.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.227-228
    • /
    • 2012
  • 본 논문에서는 스위칭 주파수의 구형파 펄스 전압 주입을 이용한 센서리스 제어시 회전자 초기 위치 추정 방법을 제안하였다. 추정된 동기좌표계 d축에 스위칭 주파수의 구형파 펄스 전압을 주입하여 회전자의 위치를 추정하고, 인덕턴스 포화현상을 이용하여 회전자의 극성을 판별하였다. 제안된 방법은 실험을 통하여 그 타당성을 검증하였다.

  • PDF

Development and application of non-invasive drug delivery systems utilizing pulse power, and its application to mouse models (펄스파워를 적용한 비침습 약물 전달기 개발 및 마우스 모델로의 적용)

  • Hwi-Chan Ham;Kyu-Sik Kim;Ji-Hwan Lee;Hyung-Jin Choi;Do-Nyun Kim;Jai-Ick Yoh
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • Some drugs can offer far better medical effectiveness as it is injected through the intradermal layer of the skin, known as a needle-free injection. However, conventional needle-free devices might deliver a relatively large amount of drug in a just single spot of skin, splitting open the tissue layer structure, which might cause bruising and bleeding. By injecting the small volume with a fast repetition rate in a large surface area of skin, the patient may get much fewer injuries and pain. To achieve that specification, the driving force must be instantaneous and short-pulsed. Such a form of an injection device has been developed but the efficacy of those devices has been rarely examined. Therefore, this study developed the laser-induced microjet device that ejects microjet whose speed is ~310 m/s, during the 400~800 ㎲ of pulse time. The device can eject ~1 µL of the drug at the rate at which each shot repeated 10 shots per second. Using this specification, we evaluated the efficacy of drug injection onto mouse models. After injecting the insulin solution into the mouse model, the blood insulin level is detected, resulting in 20 % of blood insulin level with the ordinary needle syringe injection method.