• 제목/요약/키워드: Pulse discharge

검색결과 665건 처리시간 0.046초

기체 방전관의색상 제어에 관한 연구 (A Study on Color Control in Gas Discharge Tube)

  • 이종찬;청야정명;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.285-288
    • /
    • 1996
  • The electronic operation of the gas discharge tube is controlled by the electrical energy as sinusoidal waveform in arbitrary frequency range, or as a sequence of pulses at a wide range of duty cycle, the gas composition, the kind of electrode and the vessel geometry. In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of IIg-Ne ( 10 Torr ), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency and pulse width in high voltage. As increasing pulse width and frequency in the gas discharge tube, the phenomenons that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist. The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing pulse width and frequency. The changing method of pulse width and frequency has been shown to be suitable for the luminous color control.

  • PDF

펄스 방전 기술에 의한 지반 확공 현상 수치해석 모사 (Numerical Simulation of Ground Expansion Induced by Pulse Discharge Technology)

  • 박현구;이승래;김선주;조규연
    • 한국지반공학회논문집
    • /
    • 제26권3호
    • /
    • pp.25-34
    • /
    • 2010
  • 본 연구에서는 펄스 방전 기술의 적용에 따른 지반 확공 현상에 대한 수치해석적인 연구를 수행하였다. 실내 펄스 방전 시험을 통하여 충격파 발생을 측정하였으며 수중 폭발 모델을 바탕으로한 유제-구조물 유한요소해석을 통해 실내 시험에서 계측된 충격파를 모사하였다. 이를 바탕으로, SPT N값으로부터 경험적으로 얻어지는 지반 물성이 적용된 점성토 지반에 대한 확공 해석을 수행하였으며 현장 시험과 유사한 예측 결과를 얻을 수 있었다.

초경합금의 와이어 방전가공에 의한 특성 (Characteristics in W-EDM of Tungsten Carbide)

  • 맹민재
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

ac PDP에서 Addressing 특성개선을 위한 Negative Ramp Slope이 적용된 Reset Pulse에 관한 연구 (The new reset pulse used negative ramp slope for improving the addressing characteristic in ac PDP)

  • 최혜림;정선욱;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제5권2호
    • /
    • pp.11-14
    • /
    • 2006
  • A new reset waveform with negative ramp pulse is proposed. Conventional reset waveform applied to the commercial PDP uses a positive ramp pulse. The reset waveforms, especially focused on ramp area, were examined with 2 dimensional fluid code. The proposed negative reset waveform showed much lower ignition voltage ($\sim$70V) as compared with the conventional reset waveform. When the negative ramp pulse was applied, all of the positive-charged ions are collected on the scan electrode. It is found that the ignition voltage of reset discharge due to the negative ramp pulse became lower than that of positive ramp discharge.

  • PDF

전극의 3차원 측정데이터로부터 방전가공조건 결정 (Determination of Electrical Discharge Machining Parameters from the CMM data of a Electrode)

  • 주상윤
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.58-64
    • /
    • 2000
  • This paper proposes a method for determining optimal EDM parameters based on discharge area from the physical model of a tool electrode. Main parameters, which affect the EDM performance, are peak value of currents, pulse-on time, and pulse-off time. Such parameters are closely dependent on the discharge area in EDM process. In this paper the discharge area is estimated from the CMM scanning data to the tool electrode. The method is very useful when any geometric information to the tool electrode is not provided from tool modeler or producer. The method consists of following four steps. First a triangulation mesh is constructed from the CMM data. Secondly, the z-map is modeled from the triangulated mesh. Thirdly, the discharge area is estimated from intersection between the z-map model and a z-height plane. Finally, the machining parameters are easily calculated by some known EDM equations to the discharge area. An example is introduced to show that the machining parameters are calculated from the CMM data to a tool electrode.

  • PDF

와이어방전가공시 북량현상 예측에 관한 연구 (A Study on the Hand Drum Form Predict in the Wire Electric Discharge)

  • 김선진;성백섭
    • 한국정밀공학회지
    • /
    • 제20권1호
    • /
    • pp.70-78
    • /
    • 2003
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric discharge machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to 6$mutextrm{s}$, 8$mutextrm{s}$ and 10$mutextrm{s}$, pulse-off-time to 8$mutextrm{s}$, 10$mutextrm{s}$ and 13$mutextrm{s}$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

상온 펄스 코로나 방전 공정에 의한 NO 제거 효율 (NO Removal Efficiency by Pulsed Corona Discharge Process at Room Temperature)

  • 김동주;박정환;김교선
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.337-344
    • /
    • 2002
  • In this study, we analyzed the NO removal efficiency by the pulsed corona discharge process and investigated the effects of several process variables such as initial concentrations of NO, $H_2O$, and NH$_3$, applied voltage, pulse frequency, diameter of the discharge electrode, and residence time. The removal efficiency of NO increased by the addition of $H_2O$ or NH$_3$, but the changes of initial NH$_3$ and $H_2O$ concentrations did not affect the removal efficiency of NO significantly. With the increases of the applied voltage or the residence time, the removal efficiency of NO increased. In addition, with the increases of the pulse frequency of applied voltage, or the diameter of the discharge electrode, the removal efficiency of NO increased. The experimental results can be used as a basis to design the pulsed corona discharge process to remove NO$_{x}$, SO$_{x}$ and VOCs.OCs.

저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성 (Properties of Partial Discharge accompanying with Electrical Tree in LDPE)

  • 이광우;박영국;강성화;장동욱;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

변압기내 부분방전의 종류에 따른 초음파 신호 특성 (Characteristics of Ultrasonic Signals by Partial Discharge Types)

  • 박현수;박재도;정용기;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1897-1899
    • /
    • 2000
  • This paper describes the frequency characteristics and the number of pulse of ultrasonic signals due to partial discharge occurred at each electrode. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC(b) electrode and void electrode. As a result, the dominant frequency of ultrasonic signals generated by corona in oil and partial discharge in void was hardly changed regardless with the applied voltage, but in case of surface discharge in oil, its dominant frequency moved to low frequency with the applied voltage. The increasing rate of pulse number per second was high in order of the surface discharge in oil, the partial discharge in void, the corona in oil.

  • PDF

펄스반복율의 가변에 의한 대기압 아크방전중의 고효율 금속산화물 제거 특성 (High Efficient Metal-oxide Removing Characteristics as Pulse Repetition Rates in the Atmospheric Arc Discharge)

  • 이윤수;송우정;김수원;정종한;김용철;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권4호
    • /
    • pp.179-184
    • /
    • 2003
  • The pulsed power system is widely used for many industries and environments. Generally, we call the "RUST", the reddish brown surface, that was made on iron surface or some other metals, when they are contacted by water and air the main substance of rust is oxide-ionization. In other words, the chemical symbol of rust on iron surface is iron oxide(III) hydrate Fe203.nH2O. In this study, we have designed and fabricated our system which has a compact pulse generator with switching MOSFET. Also we have studied the metal-oxide removing characteristics using in the atmospheric arc discharge. It has been investigated their removing characteristics by the change of charging voltage and pulse repetition rates. From this result, we can find out that the removal area Is increased from 3.80 to 8.04[$\textrm{cm}^2$], when pulse duration is increased from 100[pps] to 400[pps]. 400[pps].